Skip to content
SafetyRecord logoSafetyRecord
TRU-HITCH, INC.
$4,225
penalties
34
viol.
2
insp.

TRU-HITCH, INC.

1050 SOUTH MAIN STREET, TORRINGTON, CT 06790

Inspections
2
May 2000 to May 2000 · 1 safety, 1 health
Violations
34
across 2 inspections
Penalties on record
$4,225
latest amounts in DOL records
By classification
Serious 30Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 19, 2000Referral (C) · Partial scope, Health#300081593$1,20012 viol.

Inspection #300081593

Dates

Opened
May 19, 2000
Closing Conference Date
May 19, 2000
Closed
Nov 14, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
12
Violation Types
12 serious
Initial Penalties
$2,400
Penalties on Record
$1,200
Site Address
1050 South Main Street, Torrington, CT 06790
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)60mg/m³
Beryllium and Beryllium Compounds (as Be)60mg/m³
Chromium, Metal and Insoluble Salts60mg/m³
Cobalt, Metal, Dust and Fume (as Co)60mg/m³
Copper Fume (as Cu)60 - 0.0024mg/m³
Ethyl Benzene80.1688 - 1.2548ppm
Iron Oxide Fume60 - 2.6009mg/m³
Lead, Inorganic (as Pb)60mg/m³
Manganese Fume (as Mn)60 - 0.5158mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)60mg/m³
n-Butyl Acetate86.0681 - 44.3448ppm
n-Butyl Alcohol80 - 0.8628ppm
Nickel, Metal and Insoluble compounds (as Ni)60mg/m³
Petroleum Distillates (Naphtha) (Rubber Solvent)824.7221 - 319.5105mg/m³
Vanadium fume (as V2O5)60mg/m³
Xylene80.5541 - 3.6128ppm
Zinc Oxide Fume60 - 0.0075mg/m³

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.94
Ventilation
OSHA citation code: 19100094 C06 II
Serious11$600$300Mar 1, 2001--
01001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious11$0$0Mar 1, 2001--
01001C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious11$0$0Mar 1, 2001--
01001D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Serious11$0$0Jul 24, 2000--
01002A1910.94
Ventilation
OSHA citation code: 19100094 C03 IB
Serious11$600$300Mar 1, 2001--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious11$0$0Mar 1, 2001--
01003A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C06
Serious41$600$300Mar 1, 2001--
01003B1910.94
Ventilation
OSHA citation code: 19100094 C03 IA
Serious61$0$0Mar 1, 2001--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious11$600$300Mar 1, 2001--
01004B1910.134
Respiratory Protection
OSHA citation code: 19100134 H01
Serious11$0$0Jul 24, 2000--
01004C1910.134
Respiratory Protection
OSHA citation code: 19100134 H02 I
Serious11$0$0Jul 24, 2000--
01004D1910.134
Respiratory Protection
OSHA citation code: 19100134 I05 IV
Serious11$0$0Jul 24, 2000--
May 5, 2000Complaint (B) · Complete scope, Safety#116138827$3,02522 viol.

Inspection #116138827

Dates

Opened
May 5, 2000
Closing Conference Date
May 5, 2000
Closed
May 8, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 complaint

Violations and Penalties

Total Violations
22
Violation Types
18 serious, 4 other-than-serious
Initial Penalties
$6,150
Penalties on Record
$3,025
Site Address
1050 South Main Street, Torrington, CT 06790
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (22 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 F02
Serious18$450$225Oct 1, 2000--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious11$750$325Oct 1, 2000--
01003A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious15$450$225Oct 1, 2000--
01003B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F01
Serious13$0$0Oct 1, 2000--
01004A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious14$750$375Oct 1, 2000--
01004B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious14$0$0Oct 1, 2000--
01004C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious14$0$0Oct 1, 2000--
01005A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious24$750$375Sep 1, 2000--
01005B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious14$0$0Jul 26, 2000--
01006A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious14$450$225Jul 26, 2000--
01006B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious14$0$0Jul 26, 2000--
01007A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious24$450$225Sep 1, 2000--
01007B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious24$0$0Sep 1, 2000--
010081910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 II
Serious14$450$225Sep 1, 2000--
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious34$750$375Sep 1, 2000--
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Serious24$450$225Sep 1, 2000--
01011A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious14$450$225Oct 1, 2000--
01011B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious14$0$0Oct 1, 2000--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other12$0$0Sep 1, 2000--
020021910.169
Air Receivers
OSHA citation code: 19100169 B01
Other15$0$0Sep 1, 2000--
020031910.184
Slings
OSHA citation code: 19100184 E01
Other54$0$0Sep 1, 2000--
020041910.184
Slings
OSHA citation code: 19100184 I01
Other14$0$0Jul 21, 2000--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials6 citations · $625
1910.134Respiratory Protection4 citations · $300
1910.147Control of Hazardous Energy (Lockout/Tagout)3 citations · $375

Chemical exposure sampling

Samples
112
Substances
17
Inspections
1

Other inspected employers in TORRINGTON, CT

All employers in TORRINGTON →