Skip to content
SafetyRecord logoSafetyRecord
HOMETTE CORPORATION
$3,840
penalties
13
viol.
3
insp.

HOMETTE CORPORATION

99 HORSESHOE ROAD, LEOLA, PA 17540NAICS 321991 Manufactured Home (Mobile Home) Manufacturing

Inspections
3
Apr 1990 to Mar 2003 · 3 safety, 0 health
Violations
13
across 3 inspections
Penalties on record
$3,840
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 10, 2003Planned (H) · Partial scope, Safety#112988845$01 viol.

Inspection #112988845

Dates

Opened
Mar 10, 2003
Closing Conference Date
Mar 10, 2003
Closed
May 1, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
75

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
99 Horseshoe Road, Leola, PA 17540
Industry
321991 Manufactured Home (Mobile Home) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 G03
Other11$0$0Apr 16, 2003--
Apr 4, 1996Planned (H) · Complete scope, Safety#116161977$3,24010 viol.

Inspection #116161977

Dates

Opened
Apr 4, 1996
Closing Conference Date
Apr 4, 1996
Closed
Jun 10, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
120

Violations and Penalties

Total Violations
10
Violation Types
7 serious, 3 other-than-serious
Initial Penalties
$4,050
Penalties on Record
$3,240
Site Address
99 Horseshoe Road, Leola, PA 17540
Industry
321991 Manufactured Home (Mobile Home) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
Ladders
OSHA citation code: 19100023 C01
Serious14$1,350$810May 13, 1996--
01001B1910.23
Ladders
OSHA citation code: 19100023 C02
Serious14$0$0May 13, 1996--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious11$1,350$810May 5, 1996--
01003A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIB
Serious11$1,350$810May 5, 1996--
01003B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious11$0$0May 5, 1996--
01004B1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious1103$0$810May 28, 1996--
01004C1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious22$0$0May 5, 1996--
020011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Other11$0$0May 5, 1996--
020021910.38
Emergency Action Plans
OSHA citation code: 19100038 A01
Other1120$0$0May 28, 1996--
020031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other1103$0$0May 28, 1996--
Apr 24, 1990Planned (H) · Complete scope, Safety#102599461$6002 viol.

Inspection #102599461

Dates

Opened
Apr 24, 1990
Closing Conference Date
Apr 24, 1990
Closed
Jul 31, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
120

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$800
Penalties on Record
$600
Site Address
99 Horseshoe Road, Leola, PA 17540
Industry
321991 Manufactured Home (Mobile Home) Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious16$400$300Jul 1, 1990--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious12$400$300Jun 7, 1990--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.23Ladders3 citations · $1,110
1910.334Electrical - Use of Equipment2 citations · $810
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $810

Industry comparison

Violations per inspection
This employer4.3
Industry average3.3
Penalties per inspection
This employer$1,280
Industry average$2,558

Wood Product Manufacturing, 18,848 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: manufactured home (mobile home) manufacturing reported 5.6 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.0%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in LEOLA, PA