DAVIS-LYNCH GLASS CO., INC.
BOYERS AVE., STAR CITY, WV 26504 · NAICS 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 4, 2011#315225797Aug 4, 2011Planned (H) · Complete scope, Health#315225797$4,9004 viol.4 violations$4,900 in penalties
Inspection #315225797
Dates
- Opened
- Aug 4, 2011
- Closing Conference Date
- Aug 5, 2011
- Closed
- Jul 31, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 45
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $10,500
- Penalties on Record
- $4,900
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 1 | $3,500 | $2,450 | Dec 14, 2011 | - | - |
| 01001B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $0 | $0 | Dec 14, 2011 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 1 | $3,500 | $2,450 | Dec 14, 2011 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 IIIA | Other | 1 | 1 | $3,500 | $0 | Dec 14, 2011 | - | - |
Dec 12, 2007#311677074Dec 12, 2007Planned (H) · Complete scope, Health#311677074$2,70014 viol.14 violations$2,700 in penalties
Inspection #311677074
Dates
- Opened
- Dec 12, 2007
- Closing Conference Date
- Jan 11, 2008
- Closed
- Jun 5, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 12 serious, 2 other-than-serious
- Initial Penalties
- $4,725
- Penalties on Record
- $2,700
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling4 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Cadmium | 2 | 0 - 0.002 | mg/m³ |
| Ethyl Benzene | 3 | 0 | ppm |
| Lead, Inorganic (as Pb) | 2 | 0 - 0.026 | mg/m³ |
| Xylene | 3 | 0 | ppm |
Violations
Violation list (8 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 K02 | Serious | 2 | 3 | $0 | $500 | Feb 27, 2008 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 1 | 1 | $700 | $300 | Mar 5, 2008 | - | - |
| 01002C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Serious | 1 | 1 | $0 | $0 | Feb 12, 2008 | - | - |
| 01003A | 1910.134 Respiratory Protection OSHA citation code: 19100134 F02 | Serious | 1 | 1 | $875 | $400 | Feb 27, 2008 | - | - |
| 01003B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 1 | $0 | $0 | Feb 27, 2008 | - | - |
| 01003C | 1910.134 Respiratory Protection OSHA citation code: 19100134 K03 | Serious | 1 | 1 | $0 | $0 | Feb 20, 2008 | - | - |
| 01003D | 1910.134 Respiratory Protection OSHA citation code: 19100134 D03 IIIB2 | Serious | 1 | 1 | $0 | $0 | Mar 5, 2008 | - | - |
| 01004 | 1910.145 Specifications for Accident Prevention Signs and Tags OSHA citation code: 19100145 C03 | Serious | 1 | 1 | $525 | $300 | Feb 14, 2008 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 25, 2004#116223249Aug 25, 2004Planned (H) · Complete scope, Health#116223249$2,45010 viol.10 violations$2,450 in penalties
Inspection #116223249
Dates
- Opened
- Aug 25, 2004
- Closing Conference Date
- Aug 25, 2004
- Closed
- Mar 7, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 64
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 9 serious, 1 other-than-serious
- Initial Penalties
- $2,450
- Penalties on Record
- $2,450
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C01 | Serious | 2 | 1 | $525 | $525 | Sep 28, 2004 | - | - |
| 01001B | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C02 | Serious | 2 | 1 | $0 | $0 | Sep 28, 2004 | - | - |
| 01001C | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C04 | Serious | 1 | 1 | $0 | $0 | Oct 27, 2004 | - | - |
| 01001D | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 G01 | Serious | 1 | 1 | $0 | $0 | Oct 27, 2004 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 1 | $700 | $700 | Sep 21, 2004 | - | - |
| 01003A | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 1 | $700 | $700 | Sep 21, 2004 | - | - |
| 01003B | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D01 | Serious | 1 | 1 | $0 | $0 | Sep 21, 2004 | - | - |
| 01004A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B01 | Serious | 3 | 3 | $525 | $525 | Oct 27, 2004 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 15, 2001#300465234Aug 15, 2001Planned (H) · Complete scope, Health#300465234$1,05010 viol.10 violations$1,050 in penalties
Inspection #300465234
Dates
- Opened
- Aug 15, 2001
- Closing Conference Date
- Aug 16, 2001
- Closed
- Oct 15, 2001
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 65
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 7 serious, 3 other-than-serious
- Initial Penalties
- $2,100
- Penalties on Record
- $1,050
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Gravimetric DeterminationQC | 2 | 0.2868 - 1.7467 | mg/m³ |
| Sample WeightQC | 2 | 0.2 - 1.208 | mg |
| Silica, Crystalline Quartz (Respirable Fraction) | 2 | 0 - 1.7 | % |
Violations
Violation list (8 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 C01 | Serious | 1 | 1 | $700 | $350 | Nov 1, 2001 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 1 | $0 | $0 | Nov 1, 2001 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 F01 | Serious | 1 | 1 | $0 | $0 | Nov 1, 2001 | - | - |
| 01001D | 1910.134 Respiratory Protection OSHA citation code: 19100134 K03 | Serious | 1 | 1 | $0 | $0 | Nov 1, 2001 | - | - |
| 01001E | 1910.134 Respiratory Protection OSHA citation code: 19100134 H02 I | Serious | 1 | 1 | $0 | $0 | Nov 1, 2001 | - | - |
| 01002 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 1 | $700 | $350 | Oct 11, 2001 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $700 | $350 | Sep 26, 2001 | - | - |
| 02001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Other | 1 | 1 | $0 | $0 | Nov 1, 2001 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Feb 16, 1995#116272493Feb 16, 1995Planned (H) · Complete scope, Health#116272493$8,5007 viol.7 violations$8,500 in penalties
Inspection #116272493
Dates
- Opened
- Feb 16, 1995
- Closing Conference Date
- Mar 8, 1995
- Closed
- Jul 11, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 73
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 3 willful, 4 other-than-serious
- Initial Penalties
- $14,000
- Penalties on Record
- $8,500
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G01 | Willful | 5 | 8 | $14,000 | $8,500 | Jun 8, 1995 | - | - |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 J02 | Willful | 2 | 8 | $0 | $0 | May 8, 1995 | - | - |
| 01001C | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 K01 | Willful | 5 | 8 | $0 | $0 | May 8, 1995 | - | - |
| 02001 | 1910.23 Ladders OSHA citation code: 19100023 D01 III | Other | 1 | 45 | $0 | $0 | Apr 21, 1995 | - | - |
| 02002 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 D01 I | Other | 2 | 8 | $0 | $0 | May 8, 1995 | - | - |
| 02003 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 L01 | Other | 1 | 8 | $0 | $0 | May 8, 1995 | - | - |
| 02004 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A06 | Other | 1 | 45 | $0 | $0 | Apr 21, 1995 | - | - |
Dec 7, 1994#116240201Dec 7, 1994Planned (H) · Complete scope, Safety#116240201$1,6004 viol.4 violations$1,600 in penalties
Inspection #116240201
Dates
- Opened
- Dec 7, 1994
- Closing Conference Date
- Dec 7, 1994
- Closed
- Feb 17, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 75
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $2,500
- Penalties on Record
- $1,600
- Site Address
- Boyers Ave., Star City, WV 26504
- Industry
- 327212 Other Pressed and Blown Glass and Glassware Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 2 | $750 | $450 | Jan 25, 1995 | - | - |
| 01002 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $1,000 | $700 | Feb 1, 1995 | - | - |
| 01003 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 3 | $750 | $450 | Mar 1, 1995 | - | - |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 I | Other | 1 | 75 | $0 | $0 | Feb 15, 1995 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1994 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Nonmetallic Mineral Product Manufacturing, 17,192 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: other pressed and blown glass and glassware manufacturing reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 19.7%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source