Skip to content
SafetyRecord logoSafetyRecord
PILGRIM GLASS CORP
$7,410
penalties
40
viol.
9
insp.

PILGRIM GLASS CORP

WALKER BRANCH ROAD, Ceredo, WV 25507

Inspections
9
Mar 1974 to Oct 2002 · 5 safety, 4 health
Violations
40
across 9 inspections
Penalties on record
$7,410
latest amounts in DOL records
By classification
Serious 22Willful 0Repeat 0Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 21, 2002Planned (H) · No Inspection scope, Health#305488389$00 viol.

Inspection #305488389

Dates

Opened
Oct 21, 2002
Closing Conference Date
Not recorded
Closed
Oct 21, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Airport Road, Ceredo, WV 25507
Industry
327212 Other Pressed and Blown Glass and Glassware Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 24, 1999Planned (H) · Complete scope, Health#116520651$3,47011 viol.

Inspection #116520651

Dates

Opened
May 24, 1999
Closing Conference Date
Jun 1, 1999
Closed
Jul 19, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
100

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$8,180
Penalties on Record
$3,470
Site Address
Airport Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$700$280Jun 6, 1999--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 I
Serious34$1,100$440Jun 16, 1999--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$330$330Jun 16, 1999--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$1,100$440Jun 16, 1999--
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B05
Serious11$825$330Jun 28, 1999--

Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 6, 1994Planned (H) · Complete scope, Safety#116281833$2,5009 viol.

Inspection #116281833

Dates

Opened
May 6, 1994
Closing Conference Date
May 6, 1994
Closed
Jul 20, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
112

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 3 other-than-serious
Initial Penalties
$6,400
Penalties on Record
$2,500
Site Address
Airport Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious12$1,200$500Jun 10, 1994--
01001B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious12$0$0Jul 10, 1994--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious13$1,200$500Jun 1, 1994--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious33$1,200$500Jun 21, 1994--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious13$1,600$500May 27, 1994--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 11, 1988Referral (C) · Partial scope, Health#102973369$5004 viol.

Inspection #102973369

Dates

Opened
Feb 11, 1988
Closing Conference Date
Aug 8, 1988
Closed
Apr 10, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
115
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$960
Penalties on Record
$500
Site Address
Airport Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling16 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)98P / 1A0 - 2.5mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40mg/m³
Cobalt, Metal, Dust and Fume (as Co)40 - 0.0018mg/m³
Copper Fume (as Cu)40mg/m³
Iron Oxide Fume40 - 0.0117mg/m³
Lead, Inorganic (as Pb)98P / 1A0 - 0.16mg/m³
Manganese Fume (as Mn)40mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Respirable Fraction)87P / 1A0mg/m³
Selenium Compounds (as Se)54P / 1A0
Tin, inorganic compounds (except oxides) (as Sn)54P / 1A0 - 0.13
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40 - 0.003mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious12$320$250Mar 6, 1989--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious12$320$0Feb 18, 1989--
01002A1910.1025
Lead
OSHA citation code: 19101025 D07
Serious12$320$250Sep 9, 1988--
01002B1910.1025
Lead
OSHA citation code: 19101025 J01 I
Serious12$0$0Oct 6, 1988--
Jan 20, 1988Planned (H) · Complete scope, Safety#102975554$02 viol.

Inspection #102975554

Dates

Opened
Jan 20, 1988
Closing Conference Date
Jan 20, 1988
Closed
Mar 3, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
115

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Airport Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A02
Other14$0$0Feb 17, 1988--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other15$0$0Feb 2, 1988--
May 23, 1977Follow-Up (F) · Complete scope, Safety#12327276$00 viol.

Inspection #12327276

Dates

Opened
May 23, 1977
Closing Conference Date
May 23, 1977
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
100

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Walker Branch Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 4, 1977Planned (H) · Complete scope, Safety#12327201$90010 viol.

Inspection #12327201

Dates

Opened
Apr 4, 1977
Closing Conference Date
Apr 4, 1977
Closed
May 27, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
100

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 7 other-than-serious
Initial Penalties
$900
Penalties on Record
$900
Site Address
Walker Branch Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious1-$270$270Apr 23, 1977--
010021910.309
OSHA citation code: 19100309 A 011017
Serious1-$270$270Apr 23, 1977--
010031910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious2-$270$270Apr 23, 1977--
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other1-$0$0Apr 23, 1977--
020021904.5
Determination of Work-Relatedness
OSHA citation code: 19040005 A
Other1-$90$90Apr 23, 1977--

Showing the 5 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 5, 1974Complaint (B) · Partial scope, Health#12290292$02 viol.

Inspection #12290292

Dates

Opened
Nov 5, 1974
Closing Conference Date
Nov 21, 1974
Closed
Jul 15, 1975

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
110

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Walker Branch Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Other2-$0$0Jun 17, 1975--
010021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 B01
Other1-$0$0Dec 26, 1974--
Mar 20, 1974Planned (H) · Complete scope, Safety#12331211$402 viol.

Inspection #12331211

Dates

Opened
Mar 20, 1974
Closing Conference Date
Mar 20, 1974
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
110

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$40
Penalties on Record
$40
Site Address
Walker Branch Road, Ceredo, WV 25507
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other1-$40$40Apr 2, 1974--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other1-$0$0Apr 24, 1974--
Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.22Walking-Working Surfaces - General Requirements5 citations · $480
1910.219Mechanical Power-Transmission Apparatus3 citations · $770
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $880

Chemical exposure sampling

Samples
79
Substances
16
Inspections
1

Industry comparison

BLS 2024 survey: other pressed and blown glass and glassware manufacturing reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 19.7%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Ceredo, WV