SULLIVAN CUSTOM CABINETS
$930
penalties
21
viol.
3
insp.

SULLIVAN CUSTOM CABINETS

2519 OSCAR JOHNSON RD., NORTH CHARLESTON, SC 29405

Inspections
3
Aug 1993 to Apr 2010 · 3 safety, 0 health
Violations
21
across 3 inspections
Penalties on record
$930
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 14, 2010Planned (H) · Complete scope, Safety#314083130$01 viol.

Inspection #314083130

Dates

Opened
Apr 14, 2010
Closing Conference Date
Apr 16, 2010
Closed
Jul 7, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2519 Oscar Johnson Rd., North Charleston, SC 29405
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 A01
Other11$0$0Jun 15, 2010--
Dec 13, 1993Follow-Up (F) · Partial scope, Safety#124648759$00 viol.

Inspection #124648759

Dates

Opened
Dec 13, 1993
Closing Conference Date
Dec 13, 1993
Closed
Dec 30, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2519 Oscar Johnson Rd., North Charleston, SC 29405
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 23, 1993Complaint (B) · Complete scope, Safety#120491758$93020 viol.

Inspection #120491758

Dates

Opened
Aug 23, 1993
Closing Conference Date
Aug 24, 1993
Closed
Dec 30, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14
Related Activity
1 complaint

Violations and Penalties

Total Violations
20
Violation Types
8 serious, 12 other-than-serious
Initial Penalties
$2,325
Penalties on Record
$930
Site Address
2519 Oscar Johnson Rd., North Charleston, SC 29405
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (16 of 20 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C05
Serious21$300$120Nov 15, 1993--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious22$225$90Sep 22, 1993--
010031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious44$375$150Oct 16, 1993--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 G01
Serious11$375$150Sep 30, 1993--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious44$375$150Oct 30, 1993--
010061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$225$90Sep 22, 1993--
010071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC5
Serious11$225$90Sep 22, 1993--
010081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious21$225$90Sep 22, 1993--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other11$0$0Sep 16, 1993--
020021910.151
Medical Services and First Aid
OSHA citation code: 19100151 B
Other114$0$0Nov 15, 1993--
020031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Other89$0$0Nov 15, 1993--
020041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Other45$0$0Oct 16, 1993--
020051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Other44$0$0Oct 16, 1993--
020061910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Other44$0$0Sep 30, 1993--
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other11$0$0Sep 22, 1993--
020081910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Other12$0$0Sep 16, 1993--

Showing the 16 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements7 citations · $450
1910.1200Hazard Communication4 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $90

Industry comparison

BLS 2024 survey: wood kitchen cabinet and countertop manufacturing reported 3.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.2%; NAICS 33711 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in NORTH CHARLESTON, SC

All employers in NORTH CHARLESTON →