Skip to content
SafetyRecord logoSafetyRecord
D & P CUSTOM LIGHTS & PRODUCTS INC
$7,700
penalties
46
viol.
3
insp.

D & P CUSTOM LIGHTS & PRODUCTS INC

7336 COCKRILL BEND RD, NASHVILLE, TN 37209

Inspections
3
Apr 1995 to Mar 2006 · 2 safety, 1 health
Violations
46
across 3 inspections
Penalties on record
$7,700
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 22

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 1, 2006Referral (C) · Partial scope, Health#309921054$1,0009 viol.

Inspection #309921054

Dates

Opened
Mar 1, 2006
Closing Conference Date
Mar 14, 2006
Closed
Apr 25, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31
Related Activity
1 referral

Violations and Penalties

Total Violations
9
Violation Types
8 serious, 1 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
7336 Cockrill Bend Rd, Nashville, TN 37209
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious12$1,000$1,000May 2, 2006--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious12$0$0May 2, 2006--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious12$0$0May 2, 2006--
01001D1910.1052
Methylene Chloride
OSHA citation code: 19101052 D01 IA
Serious13$0$0May 2, 2006--
01001E1910.1052
Methylene Chloride
OSHA citation code: 19101052 I02
Serious13$0$0Apr 5, 2006--
01001F1910.1052
Methylene Chloride
OSHA citation code: 19101052 L03 I
Serious13$0$0Apr 5, 2006--
01001G1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious15$0$0May 2, 2006--
01001H1910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Serious15$0$0May 2, 2006--
02001900.704Other15$0$0May 2, 2006--
Feb 14, 2006Planned (H) · Complete scope, Safety#309638062$5,70014 viol.

Inspection #309638062

Dates

Opened
Feb 14, 2006
Closing Conference Date
Feb 14, 2006
Closed
Apr 11, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
31

Violations and Penalties

Total Violations
14
Violation Types
8 serious, 6 other-than-serious
Initial Penalties
$5,700
Penalties on Record
$5,700
Site Address
7336 Cockrill Bend Rd, Nashville, TN 37209
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Serious12$1,200$1,200Apr 23, 2006--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious12$1,200$1,200Apr 23, 2006--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious21$800$800Apr 23, 2006--
01004A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious14$1,000$1,000Apr 23, 2006--
01004B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 E01 IV
Serious22$0$0Apr 23, 2006--
01004C1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious14$0$0Apr 6, 2006--
01004D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious14$0$0Apr 6, 2006--
01004E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious11$0$0Apr 13, 2006--
02001300.327
OSHA citation code: 3000327 A
Other1-$400$400Apr 23, 2006--
02002900.609Other110$200$200Apr 23, 2006--
020031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other13$100$100Apr 13, 2006--
020041910.159
Automatic Sprinkler Systems
OSHA citation code: 19100159 C10
Other14$200$200Apr 13, 2006--
020051910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Other14$400$400Apr 23, 2006--
020061910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other17$200$200Apr 13, 2006--
Apr 12, 1995Planned (H) · Complete scope, Safety#120506027$1,00023 viol.

Inspection #120506027

Dates

Opened
Apr 12, 1995
Closing Conference Date
Apr 12, 1995
Closed
Jul 6, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
28

Violations and Penalties

Total Violations
23
Violation Types
8 serious, 15 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
7336 Cockrill Bend Rd, Nashville, TN 37209
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious15$150$150Jun 27, 1995--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious15$150$150Jun 27, 1995--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious12$150$150Jun 27, 1995--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious45$150$150May 24, 1995--
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious85$150$150Jun 27, 1995--
01006A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious12$150$150Jun 27, 1995--
01006B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious12$0$0Jun 27, 1995--
01006C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious12$0$0Jun 27, 1995--
02001900.609Other15$0$0Jun 27, 1995--
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other12$0$0Jun 27, 1995--
020031910.23
Ladders
OSHA citation code: 19100023 C01
Other12$0$0Jun 27, 1995--
020041910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other12$0$0May 24, 1995--
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C05
Other22$0$0Jun 27, 1995--
020061910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other12$0$0Jun 27, 1995--
020071910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Other15$0$0Jun 27, 1995--
020081910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other12$0$0May 24, 1995--

Showing the 16 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication5 citations · $150
1910.304Electrical - Wiring Design and Protection3 citations · $150
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $150

Other inspected employers in NASHVILLE, TN

All employers in NASHVILLE →