Skip to content
SafetyRecord logoSafetyRecord
POLYMERIC SYSTEMS, INC.
$931
penalties
17
viol.
2
insp.

POLYMERIC SYSTEMS, INC.

WHEATLAND AND MASON STS, PHOENIXVILLE, PA 19460NAICS 325520 Adhesive Manufacturing

Inspections
2
Oct 1984 to Feb 2004 · 1 safety, 1 health
Violations
17
across 2 inspections
Penalties on record
$931
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 26, 2004Planned (H) · Complete scope, Health#121304950$73113 viol.

Inspection #121304950

Dates

Opened
Feb 26, 2004
Closing Conference Date
Apr 29, 2004
Closed
Jun 7, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
53

Violations and Penalties

Total Violations
13
Violation Types
2 serious, 11 other-than-serious
Initial Penalties
$1,125
Penalties on Record
$731
Site Address
723 Wheatland Street, Phoenixville, PA 19460
Industry
325520 Adhesive Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling8 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Diethylenetriamine70mg/m³
Ethyl Benzene10ppm
Ethylenediamine70ppm
Gravimetric DeterminationQC30.3922 - 0.5577mg/m³
Phenol40mg/m³
Sample WeightQC30.22 - 0.384mg
Silica, Crystalline Quartz (Respirable Fraction)30 - 6.3%
Toluene10ppm
Triethylenetetramine70ppm
Xylene10ppm

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious23$500$431May 19, 2004--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious22$375$300May 22, 2004--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other153$0$0May 19, 2004--
02002A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other11$250$0May 19, 2004--
02002B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G06
Other11$0$0May 19, 2004--
02002C1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Other11$0$0Jun 16, 2004--
02002D1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other1-$0$0May 31, 2004--
020031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other153$0$0Jun 16, 2004--
02004A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other153$0$0May 19, 2004--
02004B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Other153$0$0Jun 16, 2004--
02005A1910.1020
Access to Employee Exposure and Medical Records
OSHA citation code: 19101020 G01 I
Other153$0$0Jun 16, 2004--
02005B1910.1020
Access to Employee Exposure and Medical Records
OSHA citation code: 19101020 G01 II
Other153$0$0Jun 16, 2004--
02005C1910.1020
Access to Employee Exposure and Medical Records
OSHA citation code: 19101020 G01 III
Other153$0$0Jun 16, 2004--
Oct 16, 1984Referral (C) · Partial scope, Safety#1099068$2004 viol.

Inspection #1099068

Dates

Opened
Oct 16, 1984
Closing Conference Date
Oct 16, 1984
Closed
Apr 29, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$200
Penalties on Record
$200
Site Address
Wheatland And Mason Sts, Phoenixville, PA 19460
Industry
325520 Adhesive Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious11$100$100Jan 10, 1985--
01001B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$0$0Jan 10, 1985--
01001C1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious11$0$0Dec 20, 1984--
010021910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 B
Serious12$100$100Jan 10, 1985--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.95Occupational Noise Exposure4 citations · $0
1910.304Electrical - Wiring Design and Protection3 citations · $100
1910.1020Access to Employee Exposure and Medical Records3 citations · $0

Chemical exposure sampling

Samples
37
Substances
10
Inspections
1

Industry comparison

Violations per inspection
This employer8.5
Industry average2.8
Penalties per inspection
This employer$466
Industry average$3,859

Chemical Manufacturing, 12,073 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: paint, coating, and adhesive manufacturing reported 2.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.6%; NAICS 3255 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in PHOENIXVILLE, PA

All employers in PHOENIXVILLE →