Skip to content
SafetyRecord logoSafetyRecord
NEENAH BRASS AND ALUMINUM FOUNDRY, INC.
$3,454
penalties
38
viol.
5
insp.

NEENAH BRASS AND ALUMINUM FOUNDRY, INC.

223 EDNA AVE, NEENAH, WI 54956NAICS 331524 Aluminum Foundries (except Die-Casting)

Inspections
5
Dec 1984 to Mar 2004 · 2 safety, 3 health
Violations
38
across 5 inspections
Penalties on record
$3,454
latest amounts in DOL records
By classification
Serious 22Willful 0Repeat 3Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 24, 2004Follow-Up (F) · Partial scope, Health#122017130$1,8008 viol.

Inspection #122017130

Dates

Opened
Mar 24, 2004
Closing Conference Date
Jun 24, 2004
Closed
Mar 17, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
8
Violation Types
4 serious, 3 repeat, 1 other-than-serious
Initial Penalties
$2,200
Penalties on Record
$1,800
Site Address
223 Edna Avenue, Neenah, WI 54956
Industry
331524 Aluminum Foundries (except Die-Casting)

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20.1995135 - 0.2511103mg/m³
Gravimetric DeterminationQC10.4984mg/m³
Iron Oxide Fume20 - 0.06381mg/m³
Lead, Inorganic (as Pb)20.0477355 - 0.0571724mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Sample WeightQC10.303mg
Silica, Crystalline Quartz (Respirable Fraction)111%
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20.275755 - 0.379679mg/m³

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious113$1,600$1,350Jul 31, 2004--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Repeat113$0$0Jul 31, 2004--
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Repeat113$0$0Jul 31, 2004--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$200$150Jul 31, 2004--
01003A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious12$200$150Jan 21, 2005--
01003B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Repeat12$0$0Jan 21, 2005--
010041910.1025
Lead
OSHA citation code: 19101025 D06 II
Serious12$200$150Jul 1, 2004--
020011903.19
Abatement Verification
OSHA citation code: 19030019 C01
Other113$0$0Jul 31, 2004--
Feb 6, 2003Complaint (B) · Partial scope, Health#304016470$1,55418 viol.

Inspection #304016470

Dates

Opened
Feb 6, 2003
Closing Conference Date
Feb 26, 2003
Closed
Nov 18, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 complaint

Violations and Penalties

Total Violations
18
Violation Types
16 serious, 2 other-than-serious
Initial Penalties
$2,216
Penalties on Record
$1,554
Site Address
223 Edna Avenue, Neenah, WI 54956
Industry
331419

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30.1844587 - 0.3140104mg/m³
Formaldehyde10.41ppm
Gravimetric DeterminationQC11.6009mg/m³
Iron Oxide Fume30.1485917 - 0.1822227mg/m³
Lead, Inorganic (as Pb)30.0126595 - 0.0274733mg/m³
Manganese Fume (as Mn)30.0069006 - 0.0114805mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Sample WeightQC11.172mg
Silica, Crystalline Quartz (Respirable Fraction)17.3%
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30.0963885 - 0.117609mg/m³

Violations

Violation list (10 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$225$158Jul 14, 2003--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious11$0$0Oct 12, 2003--
01001C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Oct 12, 2003--
01002A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious11$375$263Jul 14, 2003--
01002B1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious11$0$0Oct 12, 2003--
01002C1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Oct 12, 2003--
01003A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious11$300$210Jul 14, 2003--
01003B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 II
Serious11$0$0Jul 14, 2003--
01003C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious12$0$0Jul 21, 2003--
01003D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Serious12$0$0Jul 21, 2003--

Showing the 10 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 10, 1988Planned (H) · Complete scope, Safety#101298982$03 viol.

Inspection #101298982

Dates

Opened
May 10, 1988
Closing Conference Date
May 11, 1988
Closed
Jul 5, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
223 Edna Avenue, Neenah, WI 54956
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other12$0$0Jun 20, 1988--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other12$0$0Jun 20, 1988--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other11$0$0Jun 20, 1988--
Dec 20, 1984Planned (H) · Complete scope, Health#1953645$1003 viol.

Inspection #1953645

Dates

Opened
Dec 20, 1984
Closing Conference Date
Apr 26, 1985
Closed
Jun 10, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$400
Penalties on Record
$100
Site Address
223 Edna Ave, Neenah, WI 54956
Industry
331524 Aluminum Foundries (except Die-Casting)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)90mg/m³
Beryllium and Beryllium Compounds (as Be)90mg/m³
Cadmium Fume (as Cd)90 - 0.0135mg/m³
Chromium, Metal and Insoluble Salts90 - 0.004mg/m³
Cobalt, Metal, Dust and Fume (as Co)90mg/m³
Copper Fume (as Cu)90.0417 - 1.3065mg/m³
Iron Oxide Fume90.0568 - 0.7001mg/m³
Lead, Inorganic (as Pb)90 - 0.5443mg/m³
Manganese Fume (as Mn)90 - 0.0106mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)90mg/m³
Nickel, Metal and Insoluble compounds (as Ni)90 - 0.0114mg/m³
Particulates not otherwise regulated (Respirable Fraction)100mg/m³
Vanadium fume (as V2O5)90mg/m³
Zinc Oxide Fume90.5053 - 3.3281mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001B1910.1025
Lead
OSHA citation code: 19101025 E03 II
Other14$0$0Aug 30, 1985--
010021910.1025
Lead
OSHA citation code: 19101025 D01 III
Serious44$250$50Aug 30, 1985--
010031910.1025
Lead
OSHA citation code: 19101025 G01
Serious12$150$50Dec 31, 1985--
Dec 20, 1984Programmed Related (I) · Complete scope, Safety#1690221$06 viol.

Inspection #1690221

Dates

Opened
Dec 20, 1984
Closing Conference Date
Feb 19, 1985
Closed
Mar 13, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
6
Violation Types
6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
223 Edna Ave, Neenah, WI 54956
Industry
331524 Aluminum Foundries (except Die-Casting)

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.184
Slings
OSHA citation code: 19100184 E01
Other11$0$0May 27, 1985--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other12$0$0Mar 27, 1985--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other12$0$0Mar 27, 1985--
010041910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other11$0$0Feb 28, 1985--
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B02
Other12$0$0Mar 27, 1985--
010061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$0$0Feb 28, 1985--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $1,560
1910.215Abrasive Wheel Machinery7 citations · $158
1910.1000Air Contaminants6 citations · $150

Chemical exposure sampling

Samples
199
Substances
19
Inspections
3

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer7.6
Industry average3.1
Penalties per inspection
This employer$691
Industry average$2,971

Primary Metal Manufacturing, 9,077 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in NEENAH, WI