Skip to content
SafetyRecord logoSafetyRecord
MANU-TRONICS INC
$5,450
penalties
19
viol.
6
insp.

MANU-TRONICS INC

9115 26TH AVE, Kenosha, WI 53140NAICS 334412 Bare Printed Circuit Board Manufacturing

Inspections
6
Nov 1973 to Oct 2003 · 3 safety, 3 health
Violations
19
across 6 inspections
Penalties on record
$5,450
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 0Other 12

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 20, 2003Complaint (B) · Partial scope, Health#122410632$01 viol.

Inspection #122410632

Dates

Opened
Oct 20, 2003
Closing Conference Date
Oct 20, 2003
Closed
Feb 4, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
300
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
8701 100th Street, Kenosha, WI 53142
Industry
334412 Bare Printed Circuit Board Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.159
Automatic Sprinkler Systems
OSHA citation code: 19100159 C10
Other160$0$0Nov 3, 2003--
Nov 10, 1994Complaint (B) · Partial scope, Health#122040652$5,40010 viol.

Inspection #122040652

Dates

Opened
Nov 10, 1994
Closing Conference Date
Nov 21, 1994
Closed
Mar 16, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
350
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
7 serious, 3 other-than-serious
Initial Penalties
$9,450
Penalties on Record
$5,400
Site Address
8701 100th Street, Kenosha, WI 53142
Industry
334412 Bare Printed Circuit Board Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30mg/m³
Copper Fume (as Cu)30mg/m³
Iron Oxide Fume30mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30mg/m³

Violations

Violation list (8 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F04
Serious1275$1,800$1,000Feb 7, 1995--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E05
Serious12$0$0Dec 23, 1994--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious1275$2,250$1,500Jan 9, 1995--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious1275$0$0Mar 9, 1995--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious1350$1,800$1,000Dec 9, 1994--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious1350$0$0Dec 9, 1994--
010051910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious1350$1,800$1,000Mar 9, 1995--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other1350$900$900Dec 9, 1994--

Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 29, 1986Complaint (B) · Partial scope, Health#100149780$00 viol.

Inspection #100149780

Dates

Opened
Aug 29, 1986
Closing Conference Date
Sep 24, 1986
Closed
Sep 26, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
130
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
9115 26th Avenue, Kenosha, WI 53140
Industry
334412 Bare Printed Circuit Board Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Feb 28, 1978Complaint (B) · Complete scope, Safety#15458854$01 viol.

Inspection #15458854

Dates

Opened
Feb 28, 1978
Closing Conference Date
Feb 28, 1978
Closed
Jan 7, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
145
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
9115 26th Ave, Kenosha, WI 53140
Industry
334412 Bare Printed Circuit Board Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other1-$0$0Mar 16, 1978--
Jun 12, 1975Complaint (B) · Complete scope, Safety#15449747$252 viol.

Inspection #15449747

Dates

Opened
Jun 12, 1975
Closing Conference Date
Jun 18, 1975
Closed
Dec 17, 1975

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$25
Penalties on Record
$25
Site Address
9115 26th Ave, Kenosha, WI 53140
Industry
334412 Bare Printed Circuit Board Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 D01
Other1-$0$0Jun 24, 1975--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Other1-$25$25Jun 24, 1975--
Nov 7, 1973Planned (H) · Complete scope, Safety#15491178$255 viol.

Inspection #15491178

Dates

Opened
Nov 7, 1973
Closing Conference Date
Nov 7, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
87

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$25
Penalties on Record
$25
Site Address
9115 26 Avenue, Kenosha, WI 53140
Industry
334412 Bare Printed Circuit Board Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 D01 II
Other1-$0$0Dec 26, 1973--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A01
Other1-$25$25Dec 18, 1973--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other2-$0$0Dec 18, 1973--
010041910.309
OSHA citation code: 19100309 A
Other1-$0$0Jan 24, 1974--
010051910.309
OSHA citation code: 19100309 B
Other2-$0$0Dec 7, 1973--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus3 citations · $25
1910.1200Hazard Communication3 citations · $2,000
1910.147Control of Hazardous Energy (Lockout/Tagout)2 citations · $1,500

Chemical exposure sampling

Samples
34
Substances
12
Inspections
1

Industry comparison

Violations per inspection
This employer3.2
Industry average2.7
Penalties per inspection
This employer$908
Industry average$1,708

Computer and Electronic Product Manufacturing, 5,518 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: semiconductor and other electronic component manufacturing reported 0.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.8%; NAICS 33441 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Kenosha, WI