JUSTRITE MANUFACTURING COMPANY, L.L.C.
3921 DEWITT AVE., MATTOON, IL 61938
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 18, 2018#342886595Jan 18, 2018Complaint (B) · Partial scope, Safety#342886595$00 viol.0 violations$0 in penalties
Inspection #342886595
Dates
- Opened
- Jan 18, 2018
- Closing Conference Date
- Jan 18, 2018
- Closed
- May 4, 2018
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- 332431 Metal Can Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Mar 1, 2016#341298495Mar 1, 2016Complaint (B) · Partial scope, Health#341298495$6,0005 viol.5 violations$6,000 in penalties
Inspection #341298495
Dates
- Opened
- Mar 1, 2016
- Closing Conference Date
- Jul 13, 2016
- Contested
- Aug 26, 2016
- Final Order
- Apr 17, 2017
- Closed
- Oct 6, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 206
- Related Activity
- 2 complaints
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $16,000
- Penalties on Record
- $6,000
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- 332431 Metal Can Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Serious | 1 | 200 | $4,000 | $1,000 | May 17, 2017 | Aug 26, 2016 | Apr 17, 2017 |
| 01002A | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 2 | 20 | $6,000 | $4,000 | Oct 17, 2017 | Aug 26, 2016 | Apr 17, 2017 |
| 01002B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 2 | 20 | $0 | $0 | Oct 17, 2017 | Aug 26, 2016 | Apr 17, 2017 |
| 01003A | 1910.1200 Hazard Communication OSHA citation code: 19101200 H02 III | Serious | 1 | 200 | $6,000 | $1,000 | May 17, 2017 | Aug 26, 2016 | Apr 17, 2017 |
| 01003B | 1910.1200 Hazard Communication OSHA citation code: 19101200 H03 II | Serious | 1 | 200 | $0 | $0 | May 17, 2017 | Aug 26, 2016 | Apr 17, 2017 |
Oct 11, 2007#310798160Oct 11, 2007Complaint (B) · Partial scope, Safety#310798160$00 viol.0 violations$0 in penalties
Inspection #310798160
Dates
- Opened
- Oct 11, 2007
- Closing Conference Date
- Oct 11, 2007
- Closed
- Nov 14, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 240
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- 332439 Other Metal Container Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
May 13, 2005#308567080May 13, 2005Complaint (B) · Partial scope, Health#308567080$3,8525 viol.5 violations$3,852 in penalties
Inspection #308567080
Dates
- Opened
- May 13, 2005
- Closing Conference Date
- May 25, 2005
- Closed
- Nov 15, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 200
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $5,088
- Penalties on Record
- $3,852
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- 332439 Other Metal Container Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling15 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Aluminum (as Al), Metal (Total Dust) | 6 | 0 - 320 | mg/m³ |
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 6 | 0 | mg/m³ |
| Cadmium | 6 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 6 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 6 | 0 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 | mg/m³ |
| Gravimetric DeterminationQC | 6 | 0.6789 - 2.8696 | mg/m³ |
| Iron Oxide Fume | 6 | 0 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 6 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 6 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 6 | 0.6789 - 2.8696 | mg/m³ |
| Sample WeightQC | 6 | 0.092 - 1.397 | mg |
| Vanadium fume (as V2O5) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IID | Serious | 1 | 3 | $963 | $963 | Jul 16, 2005 | - | - |
| 01002A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 3 | $1,375 | $963 | Jul 23, 2005 | - | - |
| 01002B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 D04 I | Serious | 1 | 1 | $0 | $0 | Jul 10, 2005 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $1,375 | $963 | Jul 10, 2005 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C03 VIIID | Serious | 1 | 1 | $1,375 | $963 | Jul 10, 2005 | - | - |
Jul 31, 1996#300213709Jul 31, 1996Complaint (B) · Partial scope, Safety#300213709$1601 viol.1 violation$160 in penalties
Inspection #300213709
Dates
- Opened
- Jul 31, 1996
- Closing Conference Date
- Jul 31, 1996
- Closed
- Aug 30, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 175
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $160
- Penalties on Record
- $160
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Other | 1 | 12 | $160 | $160 | Aug 28, 1996 | - | - |
Feb 1, 1995#122192024Feb 1, 1995Complaint (B) · Partial scope, Health#122192024$5,08019 viol.19 violations$5,080 in penalties
Inspection #122192024
Dates
- Opened
- Feb 1, 1995
- Closing Conference Date
- Mar 7, 1995
- Closed
- Jan 30, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 130
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 11 serious, 8 other-than-serious
- Initial Penalties
- $10,525
- Penalties on Record
- $5,080
- Site Address
- 3921 Dewitt Ave., Mattoon, IL 61938
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Enforcement Outcome
Final orders are recorded through Oct 16, 1995. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Chemical Exposure Sampling4 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Hexamethylene Diisocyanate | 1 | 0 | mg/m³ |
| Methylene bisphenyl isocyanate | 1 | 0 | mg/m³ |
| Toluene-2,4-Diisocyanate (TDI) | 1 | 0 | mg/m³ |
| Toluene-2,6-Diisocyanate | 1 | 0 | mg/m³ |
Violations
Violation list (8 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.38 Emergency Action Plans OSHA citation code: 19100038 A05 II | Serious | 130 | 130 | $1,125 | $850 | Apr 21, 1995 | - | - |
| 01002 | 1910.141 Sanitation OSHA citation code: 19100141 G02 | Other | 3 | 3 | $1,125 | $0 | Apr 6, 1995 | - | - |
| 01003A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 45 | 24 | $1,300 | $975 | Apr 6, 1995 | - | - |
| 01003B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 24 | $0 | $0 | Apr 6, 1995 | - | - |
| 01004 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Other | 1 | 4 | $975 | $0 | Apr 6, 1995 | - | - |
| 01005A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Other | 2 | 4 | $1,125 | $0 | Apr 6, 1995 | - | - |
| 01005B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Other | 2 | 4 | $0 | $0 | Apr 7, 1995 | - | - |
| 01006 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 II | Serious | 2 | 4 | $1,125 | $850 | Apr 6, 1995 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 1995 to 2018. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.