Skip to content
SafetyRecord logoSafetyRecord
TITAN INTERNATIONAL, INC.
$75,000
penalties
62
viol.
2
insp.

TITAN INTERNATIONAL, INC.

2701 SPRUCE ST., QUINCY, IL 62301

Inspections
2
Jan 1997 to Feb 1997 · 1 safety, 1 health
Violations
62
across 2 inspections
Penalties on record
$75,000
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 53

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 12, 1997Referral (C) · Partial scope, Health#300215571$09 viol.

Inspection #300215571

Dates

Opened
Feb 12, 1997
Closing Conference Date
Mar 8, 1997
Contested
Jul 9, 1997
Final Order
Jun 19, 1998
Closed
Mar 25, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
840
Related Activity
1 referral

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$7,500
Penalties on Record
$0
Site Address
2701 Spruce St., Quincy, IL 62301
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)10.024mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Other13$2,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other17$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01002A1910.1025
Lead
OSHA citation code: 19101025 D02
Other11$2,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01002B1910.1025
Lead
OSHA citation code: 19101025 H01
Other11$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01002C1910.1025
Lead
OSHA citation code: 19101025 L01 I
Other11$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01003A1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 I
Other16$2,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01003B1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C02 I
Other16$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01003C1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 D04 II
Other16$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01003D1910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 F01 I
Other16$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
Jan 22, 1997Referral (C) · Complete scope, Safety#122193527$75,00053 viol.

Inspection #122193527

Dates

Opened
Jan 22, 1997
Closing Conference Date
Mar 25, 1997
Contested
Jul 9, 1997
Final Order
Jun 19, 1998
Closed
Mar 5, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
840
Related Activity
1 referral

Violations and Penalties

Total Violations
53
Violation Types
9 serious, 44 other-than-serious
Initial Penalties
$107,000
Penalties on Record
$75,000
Site Address
2701 Spruce St., Quincy, IL 62301
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (25 of 53 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious235$5,000$9,375Dec 31, 1998Jul 9, 1997Jun 19, 1998
01002A1910.67
Vehicle-Mounted Elevating and Rotating Work Platforms
OSHA citation code: 19100067 C02 II
Other11$5,000$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01002B1910.67
Vehicle-Mounted Elevating and Rotating Work Platforms
OSHA citation code: 19100067 C02 V
Other11$0$0Jun 19, 1997Jul 9, 1997Jun 19, 1998
010031910.106
Flammable Liquids
OSHA citation code: 19100106 D02
Other11$2,000$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
010041910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Other38$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
010051910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Other14$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01006A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B03
Serious33$3,500$9,375Dec 31, 1998Jul 9, 1997Jun 19, 1998
01006B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other22$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
010071910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other11$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
010081910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 D05
Other11$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01009A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C04
Other615$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01009B1910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 B
Other125$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
010101910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E02
Other11$3,500$0Jun 19, 1997Jul 9, 1997Jun 19, 1998
010111910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E09
Other11$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01012A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Other14$3,500$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01012B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Other44$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01012C1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Other14$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01012D1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Other14$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01013A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Other59$5,000$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01013B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 F03 II
Serious59$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01014A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Other59$5,000$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01014B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Other59$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01015A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Other59$5,000$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01015B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IIB
Other36$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998
01015C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 IIC2
Other36$0$0Dec 31, 1998Jul 9, 1997Jun 19, 1998

Showing the 25 violations listed first by citation identifier. This inspection has 53 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)9 citations · $0
1910.107Spray Finishing Using Flammable and Combustible Materials7 citations · $9,375
1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $9,375

Chemical exposure sampling

Samples
1
Substances
1
Inspections
1

Other inspected employers in QUINCY, IL