Skip to content
SafetyRecord logoSafetyRecord
IWI INDUSTRIES INC
$3,835
penalties
28
viol.
4
insp.

IWI INDUSTRIES INC

7738 W. 61ST PLACE, SUMMIT, IL 60501

Inspections
4
Aug 1985 to Oct 1996 · 2 safety, 2 health
Violations
28
across 4 inspections
Penalties on record
$3,835
latest amounts in DOL records
By classification
Serious 20Willful 0Repeat 0Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Oct 25, 1996Referral (C) · Partial scope, Health#300032042$05 viol.

Inspection #300032042

Dates

Opened
Oct 25, 1996
Closing Conference Date
Oct 29, 1996
Closed
Jun 6, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$750
Penalties on Record
$0
Site Address
7738 W. 61st Place, Summit, IL 60501
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.002mg/m³
Iron Oxide Fume20 - 0.3389mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20 - 0.0086mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20 - 0.0037mg/m³

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious14$750$0Dec 7, 1996--
01001B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious13$0$0Nov 23, 1996--
01001C1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious13$0$0Nov 23, 1996--
01001D1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious14$0$0Nov 8, 1996--
01001E1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious14$0$0Dec 7, 1996--
Oct 22, 1996Referral (C) · Partial scope, Safety#122281132$2,65010 viol.

Inspection #122281132

Dates

Opened
Oct 22, 1996
Closing Conference Date
Oct 29, 1996
Closed
Jun 6, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9
Related Activity
1 referral

Violations and Penalties

Total Violations
10
Violation Types
9 serious, 1 other-than-serious
Initial Penalties
$3,900
Penalties on Record
$2,650
Site Address
7738 W. 61st Place, Summit, IL 60501
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Serious17$750$500Dec 22, 1996--
01002A1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious17$750$500Nov 19, 1996--
01002B1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious17$0$0Nov 19, 1996--
010031910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Serious19$450$450Dec 22, 1996--
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$450$200Nov 29, 1996--
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Nov 30, 1996--
01005A1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B02 II
Serious17$750$500Nov 30, 1996--
01005B1910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious19$0$0Nov 30, 1996--
010061910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious37$750$500Dec 8, 1996--
020011910.141
Sanitation
OSHA citation code: 19100141 D02 II
Other29$0$0Dec 22, 1996--
Aug 19, 1985Referral (C) · Partial scope, Safety#1262658$1,1857 viol.

Inspection #1262658

Dates

Opened
Aug 19, 1985
Closing Conference Date
Aug 19, 1985
Contested
Sep 24, 1985
Final Order
May 5, 1986
Closed
Jan 6, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
6 serious, 1 other-than-serious
Initial Penalties
$2,170
Penalties on Record
$1,185
Site Address
7738 W 61st Pl, Summit, IL 60501
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious22$420$200Sep 3, 1985Sep 24, 1985May 5, 1986
010021910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 E04 III
Serious12$350$200Sep 3, 1985Sep 24, 1985May 5, 1986
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 C02 III
Serious12$350$200Sep 3, 1985Sep 24, 1985May 5, 1986
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious12$350$200Sep 10, 1985Sep 24, 1985May 5, 1986
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious12$350$200Sep 10, 1985Sep 24, 1985May 5, 1986
010061910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 B
Serious12$350$185Sep 10, 1985Sep 24, 1985May 5, 1986
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A02
Other12$0$0Sep 3, 1985-May 5, 1986
Aug 19, 1985Referral (C) · Partial scope, Health#1262559$06 viol.

Inspection #1262559

Dates

Opened
Aug 19, 1985
Closing Conference Date
Aug 19, 1985
Closed
Jan 6, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
2 referrals

Violations and Penalties

Total Violations
6
Violation Types
6 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
7738 W 61st Pl, Summit, IL 60501
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other15$0$0Oct 29, 1985--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 B03
Other15$0$0Oct 29, 1985--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 B05
Other15$0$0Oct 29, 1985--
01001D1910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Other15$0$0Oct 29, 1985--
01001E1910.134
Respiratory Protection
OSHA citation code: 19100134 B09
Other15$0$0Oct 29, 1985--
01001F1910.134
Respiratory Protection
OSHA citation code: 19100134 B10
Other15$0$0Oct 29, 1985--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection6 citations · $0
1910.1200Hazard Communication5 citations · $0
1910.106Flammable Liquids4 citations · $1,200

Chemical exposure sampling

Samples
24
Substances
12
Inspections
1

Other inspected employers in SUMMIT, IL

All employers in SUMMIT →