Skip to content
SafetyRecord logoSafetyRecord
SNC MANUFACTURING CO INC
$13,982
penalties
51
viol.
11
insp.

SNC MANUFACTURING CO INC

101 W. WAUKAU AVENUE, OSHKOSH, WI 54902NAICS 334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Inspections
11
Sep 1986 to May 2022 · 3 safety, 8 health
Violations
51
across 11 inspections
Penalties on record
$13,982
latest amounts in DOL records
By classification
Serious 25Willful 0Repeat 0Other 26

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 3, 2022Complaint (B) · Partial scope, Health#345933550$00 viol.

Inspection #345933550

Dates

Opened
May 3, 2022
Closing Conference Date
May 3, 2022
Closed
Sep 30, 2022

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
57
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 W. Waukau Ave., Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

May 15, 2012Complaint (B) · Partial scope, Health#334311321$2,9164 viol.

Inspection #334311321

Dates

Opened
May 15, 2012
Closing Conference Date
May 15, 2012
Final Order
Nov 27, 2012
Closed
Dec 14, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
60
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$4,165
Penalties on Record
$2,916
Site Address
101 W. Waukau Ave., Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 C
Serious11$2,380$1,666Nov 1, 2012-Nov 27, 2012
01001B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious11$0$0Nov 1, 2012-Nov 27, 2012
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,785$1,250Dec 14, 2012-Nov 27, 2012
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other11$0$0Nov 1, 2012-Nov 27, 2012
Sep 14, 2006Complaint (B) · Partial scope, Safety#122017767$3,5001 viol.

Inspection #122017767

Dates

Opened
Sep 14, 2006
Closing Conference Date
Sep 27, 2006
Closed
Aug 23, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
100
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$3,500
Penalties on Record
$3,500
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$3,500$3,500Aug 21, 2007--
Jul 20, 2005Programmed Other (K) · Partial scope, Health#306799149$01 viol.

Inspection #306799149

Dates

Opened
Jul 20, 2005
Closing Conference Date
Jul 26, 2005
Closed
Mar 16, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
124

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
335311 Power, Distribution, and Specialty Transformer Manufacturing

Programmed Other Inspection: This inspection record is categorized as a programmed other inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other2-$0$0Nov 17, 2005--
Jun 11, 2003Complaint (B) · Partial scope, Health#304017718$01 viol.

Inspection #304017718

Dates

Opened
Jun 11, 2003
Closing Conference Date
Jun 12, 2003
Closed
Apr 21, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
120
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
335311 Power, Distribution, and Specialty Transformer Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling17 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20 - 0.0062402mg/m³
Dimethyl Acetamide40ppm
Gravimetric DeterminationQC30.1236 - 0.4231mg/m³
Iron Oxide Fume20mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Mica10.1236mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)10.1236mg/m³
Particulates not otherwise regulated (Total Dust)20.1803 - 0.4231mg/m³
Sample WeightQC30.057 - 0.219mg
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Other120$0$0Aug 18, 2003--
Mar 6, 2003Complaint (B) · Partial scope, Health#304016736$1,5764 viol.

Inspection #304016736

Dates

Opened
Mar 6, 2003
Closing Conference Date
Mar 7, 2003
Closed
Jun 10, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
120
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$2,250
Penalties on Record
$1,576
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
335311 Power, Distribution, and Specialty Transformer Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium10mg/m³
Chromium, Metal and Insoluble Salts10mg/m³
Cobalt, Metal, Dust and Fume (as Co)10mg/m³
Copper Fume (as Cu)10.0079236mg/m³
Gravimetric DeterminationQC11.5184mg/m³
Iron Oxide Fume10.4138329mg/m³
Lead, Inorganic (as Pb)10mg/m³
Manganese Fume (as Mn)10mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)10mg/m³
Particulates not otherwise regulated (Total Dust)11.5184mg/m³
Sample WeightQC10.254mg
Vanadium fume (as V2O5)10mg/m³
Zinc Oxide Fume10mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.124
General Requirements for Dipping and Coating Operations
OSHA citation code: 19100124 G02
Serious11$1,125$788Jun 10, 2003--
01001B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious11$0$0May 12, 2003--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious12$1,125$788Jun 10, 2003--
020011910.141
Sanitation
OSHA citation code: 19100141 A03 I
Other11$0$0May 26, 2003--
Oct 29, 1998Complaint (B) · Partial scope, Health#300483054$1,7506 viol.

Inspection #300483054

Dates

Opened
Oct 29, 1998
Closing Conference Date
Oct 29, 1998
Closed
Jul 21, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
322
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$3,500
Penalties on Record
$1,750
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acrolein10
Formaldehyde10

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious16$2,000$1,250Jul 6, 1999--
01001B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F07 III
Serious16$0$0Jul 6, 1999--
01001C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 II
Serious16$0$0Jul 6, 1999--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious120$1,500$500Apr 30, 1999--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious120$0$0Apr 30, 1999--

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 26, 1994Complaint (B) · Partial scope, Health#122484991$3,05011 viol.

Inspection #122484991

Dates

Opened
Jul 26, 1994
Closing Conference Date
Jul 28, 1994
Closed
Jan 5, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
322
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
7 serious, 4 other-than-serious
Initial Penalties
$6,000
Penalties on Record
$3,050
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling9 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Copper Fume (as Cu)40mg/m³
Fluorides (as F)30mg/m³
Lead, Inorganic (as Pb)40mg/m³
Silver, Metal and Soluble Compounds (as Ag)40mg/m³
Styrene40.2019 - 1.0011ppm
Tin, inorganic compounds (except oxides) (as Sn)40mg/m³
Zinc Oxide Fume40mg/m³

Violations

Violation list (5 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.138
Hand Protection
OSHA citation code: 19100138 A
Serious12$1,125$650Sep 13, 1994--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious14$1,500$850Dec 31, 1994--
01003A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious14$1,125$650Dec 31, 1994--
01003B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IV
Serious14$0$0Nov 1, 1994--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious11$1,125$400Aug 29, 1994--

Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 1, 1988Complaint (B) · Complete scope, Health#101728301$1,19011 viol.

Inspection #101728301

Dates

Opened
Nov 1, 1988
Closing Conference Date
Nov 3, 1988
Closed
Sep 28, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
265
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
6 serious, 5 other-than-serious
Initial Penalties
$2,000
Penalties on Record
$1,190
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling20 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Acetone3237.0558 - 837.5194ppm
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Iron Oxide Fume20 - 0.0197mg/m³
Lead, Inorganic (as Pb)80mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
n-Butyl Acetate40ppm
n-Butyl Alcohol50.9825 - 8.549ppm
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)70mg/m³
Petroleum Distillates (Naphtha) (Rubber Solvent)757.2198 - 421.265mg/m³
Tin, inorganic compounds (except oxides) (as Sn)60mg/m³
Vanadium fume (as V2O5)20mg/m³
Xylene91.0696 - 13.3974ppm
Zinc Oxide Fume20mg/m³

Violations

Violation list (5 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVA
Serious11$320$320Mar 1, 1989--
01001B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Serious11$0$0Mar 1, 1989--
01001C1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious11$0$0Mar 1, 1989--
020011910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Other11$0$0Mar 1, 1989--
020021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Other11$0$0Mar 1, 1989--

Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 13, 1988Complaint (B) · Partial scope, Safety#102537685$02 viol.

Inspection #102537685

Dates

Opened
Oct 13, 1988
Closing Conference Date
Nov 1, 1988
Closed
Nov 23, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
265
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
101 W. Waukau Avenue, Oshkosh, WI 54902
Industry
334416 Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Other115$0$0Nov 21, 1988--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIG
Other14$0$0Nov 28, 1988--
Inspections 1 to 10 of 11, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication10 citations · $500
1910.106Flammable Liquids4 citations · $320
1910.147Control of Hazardous Energy (Lockout/Tagout)4 citations · $2,288

Chemical exposure sampling

Samples
165
Substances
31
Inspections
5

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer4.6
Industry average2.7
Penalties per inspection
This employer$1,271
Industry average$1,696

Computer and Electronic Product Manufacturing, 5,598 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in OSHKOSH, WI

All employers in OSHKOSH →