COLONIAL WOODCRAFT, INC.
$1,925
penalties
29
viol.
2
insp.

COLONIAL WOODCRAFT, INC.

RACE STREET, BRISTOL, CT 06011

Inspections
2
Nov 1993 to Apr 1994 · 2 safety, 0 health
Violations
29
across 2 inspections
Penalties on record
$1,925
latest amounts in DOL records
By classification
Serious 23Willful 0Repeat 6Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 21, 1994Follow-Up (F) · Partial scope, Safety#123208993$1,3006 viol.

Inspection #123208993

Dates

Opened
Apr 21, 1994
Closing Conference Date
Apr 21, 1994
Closed
Aug 16, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
6
Violation Types
6 repeat
Initial Penalties
$2,600
Penalties on Record
$1,300
Site Address
Race Street, Bristol, CT 06011
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Repeat12$1,200$600Jul 5, 1994--
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Repeat12$0$0Jul 5, 1994--
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Repeat14$1,200$600Jul 5, 1994--
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Repeat14$0$0Jul 5, 1994--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Repeat61$100$50Jul 5, 1994--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Repeat59$100$50Jul 5, 1994--
Nov 8, 1993Complaint (B) · Complete scope, Safety#123211674$62523 viol.

Inspection #123211674

Dates

Opened
Nov 8, 1993
Closing Conference Date
Nov 9, 1993
Closed
Jul 7, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9
Related Activity
1 complaint

Violations and Penalties

Total Violations
23
Violation Types
23 serious
Initial Penalties
$625
Penalties on Record
$625
Site Address
Race Street, Bristol, CT 06011
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (23 of 23 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
Flammable Liquids
OSHA citation code: 19100106 D07 I
Serious19$75$75Jan 19, 1994--
01001B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB2
Serious19$0$0Mar 1, 1994--
01001C1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious19$0$0Dec 17, 1993--
01001D1910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Serious19$0$0Jan 19, 1994--
01002A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious29$75$75Mar 1, 1994--
01002B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C05
Serious19$0$0Mar 1, 1994--
01003A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious13$75$75Mar 1, 1994--
01003B1910.134
Respiratory Protection
OSHA citation code: 19100134 B02
Serious13$0$0Mar 1, 1994--
01003C1910.134
Respiratory Protection
OSHA citation code: 19100134 B10
Serious13$0$0Jan 19, 1994--
01004A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious19$75$75Jan 19, 1994--
01004B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious19$0$0Jan 19, 1994--
01004C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious19$0$0Jan 19, 1994--
01004D1910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 B02 I
Serious19$0$0Jan 19, 1994--
01005A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious19$75$75Jan 19, 1994--
01005B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious19$0$0Jan 19, 1994--
01005C1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious19$0$0Jan 19, 1994--
01005D1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 M01
Serious29$0$0Jan 19, 1994--
01006A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious19$75$75Jan 19, 1994--
01006B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious39$0$0Mar 1, 1994--
01007A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious339$100$100Mar 1, 1994--
01007B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious19$0$0Jan 19, 1994--
01008A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious19$75$75Jan 19, 1994--
01008B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious19$0$0Jan 19, 1994--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements6 citations · $675
1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $675
1910.106Flammable Liquids4 citations · $75

Other inspected employers in BRISTOL, CT

All employers in BRISTOL →