Skip to content
SafetyRecord logoSafetyRecord
ADVANTAGE SHEET METAL MFG. INC.
$8,625
penalties
29
viol.
2
insp.

ADVANTAGE SHEET METAL MFG. INC.

51 ELM STREET, NAUGATUCK, CT 06770NAICS 332116

Inspections
2
Oct 2002 to Nov 2002 · 1 safety, 1 health
Violations
29
across 2 inspections
Penalties on record
$8,625
latest amounts in DOL records
By classification
Serious 25Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 20, 2002Referral (C) · Complete scope, Health#305190472$2,62511 viol.

Inspection #305190472

Dates

Opened
Nov 20, 2002
Closing Conference Date
Mar 26, 2003
Closed
Apr 21, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
43
Related Activity
1 referral

Violations and Penalties

Total Violations
11
Violation Types
10 serious, 1 other-than-serious
Initial Penalties
$5,250
Penalties on Record
$2,625
Site Address
51 Elm Street, Naugatuck, CT 06770
Industry
332116

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)20mg/m³
Beryllium and Beryllium Compounds (as Be)20mg/m³
Cadmium20mg/m³
Chromium, Metal and Insoluble Salts20mg/m³
Cobalt, Metal, Dust and Fume (as Co)20mg/m³
Copper Fume (as Cu)20mg/m³
Gravimetric DeterminationQC10.5173mg/m³
Iron Oxide Fume20.1077836 - 0.1647198mg/m³
Lead, Inorganic (as Pb)20mg/m³
Manganese Fume (as Mn)20mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)20mg/m³
Nickel, Metal and Insoluble compounds (as Ni)20mg/m³
Particulates not otherwise regulated (Respirable Fraction)10.5173mg/m³
Sample WeightQC10.394mg
Vanadium fume (as V2O5)20mg/m³
Zinc Oxide Fume20mg/m³

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Serious12$750$375Apr 29, 2003--
01001B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Serious12$0$0Apr 29, 2003--
01001C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 C02
Serious12$0$0Apr 29, 2003--
01001D1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 L04 I
Serious12$0$0Apr 29, 2003--
01001E1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 L04 III
Serious12$0$0Apr 29, 2003--
010021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious15$1,250$625Apr 29, 2003--
010031910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$1,250$625Apr 29, 2003--
010041910.307
Electrical - Hazardous (Classified) Locations
OSHA citation code: 19100307 B02 I
Serious12$1,250$625Jun 30, 2003--
01005A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious12$750$375Jun 30, 2003--
01005B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious12$0$0Jun 30, 2003--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other12$0$0Jun 30, 2003--
Oct 24, 2002Referral (C) · Complete scope, Safety#123286940$6,00018 viol.

Inspection #123286940

Dates

Opened
Oct 24, 2002
Closing Conference Date
Jan 10, 2003
Closed
Jul 25, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40
Related Activity
1 referral

Violations and Penalties

Total Violations
18
Violation Types
15 serious, 3 other-than-serious
Initial Penalties
$10,500
Penalties on Record
$6,000
Site Address
51 Elm Street, Naugatuck, CT 06770
Industry
332116

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (18 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious1-$1,000$500Feb 25, 2003--
010025A0001
General Duty Clause, Section 5(a)(1)
Serious1-$1,000$500Mar 25, 2003--
01003A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious18$1,750$1,000Apr 25, 2003--
01003B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious18$0$0Apr 25, 2003--
01003C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious18$0$0Apr 25, 2003--
01004A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 G02
Serious1-$750$450Feb 25, 2003--
01004B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious14$0$0Feb 25, 2003--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious1-$1,250$700Feb 25, 2003--
01006A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious67$2,500$1,500Apr 25, 2003--
01006B1910.255
Resistance Welding
OSHA citation code: 19100255 B04
Serious32$0$0Apr 25, 2003--
010071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious29$750$450Feb 25, 2003--
01008A1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious29$750$450Feb 25, 2003--
01008B1910.255
Resistance Welding
OSHA citation code: 19100255 B05
Serious39$0$0Mar 25, 2003--
01009A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious330$750$450Feb 25, 2003--
01009B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious15$0$0Feb 25, 2003--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other19$0$0Jan 27, 2003--
020021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 E01 IV
Other130$0$0Jan 27, 2003--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other330$0$0Jan 27, 2003--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials5 citations · $375
1910.147Control of Hazardous Energy (Lockout/Tagout)3 citations · $1,000
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $450

Chemical exposure sampling

Samples
29
Substances
16
Inspections
1

Industry comparison

Violations per inspection
This employer14.5
Industry average3.3
Penalties per inspection
This employer$4,313
Industry average$2,288

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in NAUGATUCK, CT