CROWN METAL BUILDINGS
203 S. 10TH ST., CABOT, AR 72023
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 26, 2011#315438093Apr 26, 2011Planned (H) · Complete scope, Safety#315438093$4,5904 viol.4 violations$4,590 in penalties
Inspection #315438093
Dates
- Opened
- Apr 26, 2011
- Closing Conference Date
- Apr 26, 2011
- Closed
- Dec 4, 2015
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 11
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $4,590
- Penalties on Record
- $4,590
- Site Address
- 203 S. 10th St., Cabot, AR 72073
- Industry
- 332311 Prefabricated Metal Building and Component Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $2,040 | $2,040 | Jun 1, 2011 | - | - |
| 01002A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 1 | $2,550 | $2,550 | May 30, 2011 | - | - |
| 01002B | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 II | Serious | 1 | 1 | $0 | $0 | May 30, 2011 | - | - |
| 02001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Other | 1 | 1 | $0 | $0 | Jun 1, 2011 | - | - |
Apr 13, 1998#123373698Apr 13, 1998Planned (H) · Complete scope, Safety#123373698$7,15013 viol.13 violations$7,150 in penalties
Inspection #123373698
Dates
- Opened
- Apr 13, 1998
- Closing Conference Date
- Apr 16, 1998
- Closed
- Aug 17, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 9 serious, 1 repeat, 3 other-than-serious
- Initial Penalties
- $15,300
- Penalties on Record
- $7,150
- Site Address
- 203 S. 10th St., Cabot, AR 72023
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C05 | Serious | 3 | 1 | $2,100 | $1,050 | Aug 5, 1998 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C08 | Serious | 2 | 1 | $0 | $0 | Aug 5, 1998 | - | - |
| 01002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | 1 | $2,100 | $1,050 | Jul 8, 1998 | - | - |
| 01003 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 M02 | Serious | 2 | 2 | $1,500 | $750 | Jul 9, 1998 | - | - |
| 01004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 1 | $1,500 | $750 | Jul 8, 1998 | - | - |
| 01005A | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 5 | 6 | $1,500 | $750 | Jul 8, 1998 | - | - |
| 01005B | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 I | Serious | 4 | 4 | $0 | $0 | Jul 8, 1998 | - | - |
| 01006 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Serious | 1 | 2 | $1,500 | $750 | Jul 8, 1998 | - | - |
| 01007 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 1 | 2 | $1,500 | $750 | Jul 8, 1998 | - | - |
| 02001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02II | Repeat | 3 | 4 | $3,000 | $1,000 | Aug 5, 1998 | - | - |
| 03001 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 G01V | Other | 1 | 12 | $0 | $0 | Jul 22, 1998 | - | - |
| 03002 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 A01 | Other | 1 | 1 | $600 | $300 | Jul 8, 1998 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 13, 1998#116489451Apr 13, 1998Planned (H) · Complete scope, Health#116489451$2,8509 viol.9 violations$2,850 in penalties
Inspection #116489451
Dates
- Opened
- Apr 13, 1998
- Closing Conference Date
- Apr 16, 1998
- Closed
- Aug 10, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 75
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 5 serious, 4 other-than-serious
- Initial Penalties
- $5,700
- Penalties on Record
- $2,850
- Site Address
- 203 S. 10th St., Cabot, AR 72023
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling12 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 3 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 3 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 3 | 0 - 0.0016 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 3 | 0 | mg/m³ |
| Copper Fume (as Cu) | 3 | 0.0049 - 0.0198 | mg/m³ |
| Gravimetric DeterminationQC | 3 | 2.2813 - 4.1933 | mg/m³ |
| Iron Oxide Fume | 3 | 0.7055 - 2.224 | mg/m³ |
| Lead, Inorganic (as Pb) | 3 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 3 | 0.1216 - 0.1858 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 3 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 3 | 0 | mg/m³ |
| Sample WeightQC | 3 | 0.073 - 1.887 | mg |
| Vanadium fume (as V2O5) | 3 | 0 | mg/m³ |
| Zinc Oxide Fume | 3 | 0 - 0.0062 | mg/m³ |
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 2 | 10 | $1,200 | $600 | Jul 15, 1998 | - | - |
| 01002 | 1910.138 Hand Protection OSHA citation code: 19100138 A | Serious | 1 | 2 | $900 | $450 | Jul 8, 1998 | - | - |
| 01003 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $900 | $450 | Aug 4, 1998 | - | - |
| 01004 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 B02 IB | Serious | 1 | 1 | $1,200 | $600 | Jul 15, 1998 | - | - |
| 01005 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H02 II | Serious | 1 | 2 | $900 | $450 | Jul 22, 1998 | - | - |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Other | 19 | 75 | $600 | $300 | Jul 29, 1998 | - | - |
| 02002 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G01 | Other | 3 | 3 | $0 | $0 | Jul 25, 1998 | - | - |
| 02003A | 1910.134 Respiratory Protection OSHA citation code: 19100134 B10 | Other | 1 | 2 | $0 | $0 | Jul 29, 1998 | - | - |
| 02003B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 | Other | 1 | 2 | $0 | $0 | Jul 29, 1998 | - | - |
Nov 2, 1995#123436321Nov 2, 1995Planned (H) · Complete scope, Safety#123436321$1,83911 viol.11 violations$1,839 in penalties
Inspection #123436321
Dates
- Opened
- Nov 2, 1995
- Closing Conference Date
- Nov 2, 1995
- Closed
- Jan 12, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 10 serious, 1 other-than-serious
- Initial Penalties
- $3,675
- Penalties on Record
- $1,839
- Site Address
- 1100 Elm St., Cabot, AR 72023
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (11 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $700 | $350 | Dec 22, 1995 | - | - |
| 01001B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $0 | $0 | Dec 22, 1995 | - | - |
| 01001C | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $0 | $0 | Dec 22, 1995 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 2 | 7 | $875 | $438 | Dec 15, 1995 | - | - |
| 01003A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 7 | $700 | $350 | Dec 15, 1995 | - | - |
| 01003B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 2 | 7 | $0 | $0 | Dec 15, 1995 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 3 | 2 | $875 | $438 | Dec 22, 1995 | - | - |
| 01005A | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 C01 I | Serious | 1 | 1 | $525 | $263 | Jan 2, 1996 | - | - |
| 01005B | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 F02 I | Serious | 1 | 1 | $0 | $0 | Jan 2, 1996 | - | - |
| 01005C | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 I | Serious | 1 | 1 | $0 | $0 | Jan 2, 1996 | - | - |
| 02001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 II | Other | 1 | 1 | $0 | $0 | Dec 22, 1995 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1995 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Industry comparison
BLS 2024 survey: prefabricated metal building and component manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source