Skip to content
SafetyRecord logoSafetyRecord
SURRY COUNTY SCHOOL BUS GARAGE
$0
penalties
23
viol.
3
insp.

SURRY COUNTY SCHOOL BUS GARAGE

114 LIBERTY STREET, DENDRON, VA 23839

Inspections
3
Oct 1983 to Dec 1993 · 3 safety, 0 health
Violations
23
across 3 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 2, 1993Follow-Up (F) · Partial scope, Safety#123671448$00 viol.

Inspection #123671448

Dates

Opened
Dec 2, 1993
Closing Conference Date
Dec 2, 1993
Closed
Dec 7, 1993

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
114 Liberty Street, Dendron, VA 23839
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Sep 1, 1993Planned (H) · Complete scope, Safety#123667750$010 viol.

Inspection #123667750

Dates

Opened
Sep 1, 1993
Closing Conference Date
Sep 2, 1993
Closed
Nov 19, 1993

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
10
Violation Types
7 serious, 3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
114 Liberty Street, Dendron, VA 23839
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious13$0$0Oct 7, 1993--
010021910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Serious13$0$0Oct 18, 1993--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious13$0$0Oct 12, 1993--
010041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious13$0$0Oct 12, 1993--
01005A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious13$0$0Oct 12, 1993--
01005B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious13$0$0Oct 12, 1993--
01005C1910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious13$0$0Nov 5, 1993--
02001ARM001101
OSHA citation code: ARM001101 A
Other13$0$0Oct 18, 1993--
020021910.244
Other Portable Tools and Equipment
OSHA citation code: 19100244 A01 II
Other13$0$0Oct 12, 1993--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other13$0$0Oct 12, 1993--
Oct 5, 1983Planned (H) · Complete scope, Safety#12586996$013 viol.

Inspection #12586996

Dates

Opened
Oct 5, 1983
Closing Conference Date
Oct 5, 1983
Closed
Nov 30, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
13
Violation Types
2 serious, 11 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hwy 31, Dendron, VA 23839
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (13 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$0$0Dec 5, 1983--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious1-$0$0Dec 5, 1983--
020011910.106
Flammable Liquids
OSHA citation code: 19100106 D02 I
Other1-$0$0Nov 10, 1983--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Other1-$0$0Nov 20, 1983--
020031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other1-$0$0Nov 10, 1983--
020041910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other1-$0$0Nov 10, 1983--
020051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 D03
Other1-$0$0Nov 10, 1983--
020061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other3-$0$0Dec 5, 1983--
020071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F01 IV
Other1-$0$0Dec 5, 1983--
020081910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other5-$0$0Dec 5, 1983--
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other2-$0$0Dec 5, 1983--
020101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other1-$0$0Dec 5, 1983--
020111910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J01 II
Other1-$0$0Dec 5, 1983--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.304Electrical - Wiring Design and Protection4 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $0
1910.215Abrasive Wheel Machinery3 citations · $0

Other inspected employers in DENDRON, VA