Skip to content
SafetyRecord logoSafetyRecord
SCHOOL 16 TROY CITY SCHOOL DISTRICT
$0
penalties
18
viol.
4
insp.

SCHOOL 16 TROY CITY SCHOOL DISTRICT

COLLINS & WALKER AVE, TROY, NY 12180

Inspections
4
May 1987 to Jun 1995 · 4 safety, 0 health
Violations
18
across 4 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 7, 1995Follow-Up (F) · Partial scope, Safety#124537994$00 viol.

Inspection #124537994

Dates

Opened
Jun 7, 1995
Closing Conference Date
Jun 7, 1995
Closed
Jun 7, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Collins And 6 Allon Ave., Troy, NY 12180
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 2, 1995Follow-Up (F) · Partial scope, Safety#124537051$00 viol.

Inspection #124537051

Dates

Opened
Mar 2, 1995
Closing Conference Date
Mar 2, 1995
Closed
Mar 2, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Collins And 6 Allon Ave., Troy, NY 12180
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 18, 1994Planned (H) · Complete scope, Safety#124528431$017 viol.

Inspection #124528431

Dates

Opened
Aug 18, 1994
Closing Conference Date
Aug 18, 1994
Closed
Jun 9, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
17
Violation Types
15 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Collins And 6 Allon Ave., Troy, NY 12180
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (12 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 D02
Serious110$0$0Feb 24, 1995--
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious13$0$0Feb 24, 1995--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious210$0$0Jan 26, 1995--
010041910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01 II
Serious44$0$0Feb 2, 1995--
010051910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious810$0$0Jan 26, 1995--
010061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious11$0$0Jan 26, 1995--
010071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious13$0$0Jan 26, 1995--
010081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious24$0$0Jan 26, 1995--
010091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious16$0$0Jan 26, 1995--
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious13$0$0Jan 26, 1995--
010111910.306
Electrical - Specific Purpose Equipment and Installations
OSHA citation code: 19100306 J02 I
Serious23$0$0Jan 26, 1995--
010121910.306
Electrical - Specific Purpose Equipment and Installations
OSHA citation code: 19100306 J02 I
Serious33$0$0Jan 26, 1995--

Showing the 12 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Failure to Abate Penalties2 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01011#124537051Apr 24, 1995---

Showing the 1 FTA rows present in the first 12 citations on this inspection. OSHA's record shows 2 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.

May 7, 1987Planned (H) · Complete scope, Safety#104830674$01 viol.

Inspection #104830674

Dates

Opened
May 7, 1987
Closing Conference Date
May 7, 1987
Closed
Dec 31, 1999

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
41

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Collins & Walker Ave, Troy, NY 12180
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
120011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q08
Other12$0$0Jul 1, 1987--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.306Electrical - Specific Purpose Equipment and Installations2 citations · $0
1910.334Electrical - Use of Equipment2 citations · $0

Other inspected employers in TROY, NY

All employers in TROY →