VENTURE INDUSTRIES CORP
17085 MASONIC, FRASER, MI 48026
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Dec 18, 2002#304882483Dec 18, 2002Planned (H) · Complete scope, Safety#304882483$4,90326 viol.26 violations$4,903 in penalties
Inspection #304882483
Dates
- Opened
- Dec 18, 2002
- Closing Conference Date
- Dec 23, 2002
- Closed
- Mar 20, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 85
Violations and Penalties
- Total Violations
- 26
- Violation Types
- 14 serious, 12 other-than-serious
- Initial Penalties
- $9,800
- Penalties on Record
- $4,903
- Site Address
- 17085 Masonic, Fraser, MI 48026
- Industry
- 326199 All Other Plastics Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (25 of 26 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 4081003409 | Serious | 3 | 5 | $700 | $350 | Mar 19, 2003 | - | - |
| 01002 | 4081003410 | Serious | 1 | 3 | $525 | $263 | Mar 19, 2003 | - | - |
| 01003 | 4081012601 | Serious | 1 | 1 | $525 | $263 | Mar 19, 2003 | - | - |
| 01004 | 4081021302 | Serious | 1 | 1 | $700 | $350 | Mar 19, 2003 | - | - |
| 01005 | 4081063205 | Serious | 1 | 2 | $700 | $350 | Feb 25, 2003 | - | - |
| 01006 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 1 | $700 | $350 | Mar 19, 2003 | - | - |
| 01007 | 4081621101 | Serious | 1 | 1 | $875 | $438 | Mar 19, 2003 | - | - |
| 01008 | 4081622703 | Serious | 3 | 1 | $875 | $438 | Mar 19, 2003 | - | - |
| 01009 | 4081622202 | Serious | 2 | 2 | $1,225 | $613 | Mar 19, 2003 | - | - |
| 01010 | 4081623401 | Serious | 1 | 2 | $700 | $350 | Mar 19, 2003 | - | - |
| 01011A | 4081623606 | Serious | 1 | 2 | $700 | $350 | Mar 19, 2003 | - | - |
| 01011B | 4081003409 | Serious | 1 | 5 | $0 | $0 | Mar 19, 2003 | - | - |
| 01012 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 3 | 4 | $875 | $438 | Mar 19, 2003 | - | - |
| 01013 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 G01 | Serious | 1 | 4 | $700 | $350 | Apr 11, 2003 | - | - |
| 02001 | 4081.1254 OSHA citation code: 40811254 B | Other | 1 | 1 | $0 | $0 | Feb 25, 2003 | - | - |
| 02002 | 4081273201 | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
| 02003 | 4081.2741 | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
| 02004 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
| 02005 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 1 | 1 | $0 | $0 | Feb 25, 2003 | - | - |
| 02006 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A01 I | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
| 02007 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
| 02008 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Other | 1 | 2 | $0 | $0 | Mar 19, 2003 | - | - |
| 02009 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C01 | Other | 2 | 5 | $0 | $0 | Mar 19, 2003 | - | - |
| 02010 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C02 | Other | 7 | 5 | $0 | $0 | Mar 19, 2003 | - | - |
| 02011 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Other | 1 | 1 | $0 | $0 | Mar 19, 2003 | - | - |
Showing the 25 violations listed first by citation identifier. This inspection has 26 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 24, 1996#124827999Sep 24, 1996Planned (H) · Complete scope, Safety#124827999$60014 viol.14 violations$600 in penalties
Inspection #124827999
Dates
- Opened
- Sep 24, 1996
- Closing Conference Date
- Oct 2, 1996
- Closed
- Dec 23, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 100
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 4 serious, 10 other-than-serious
- Initial Penalties
- $1,200
- Penalties on Record
- $600
- Site Address
- 17085 Masonic, Fraser, MI 48026
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (14 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 4081003410 | Serious | 1 | 4 | $300 | $150 | Dec 2, 1996 | - | - |
| 01002 | 4081021302 | Serious | 1 | 1 | $300 | $150 | Dec 2, 1996 | - | - |
| 01003 | 4081072701 | Serious | 1 | 2 | $300 | $150 | Dec 2, 1996 | - | - |
| 01004 | 4081273201 | Serious | 1 | 1 | $300 | $150 | Dec 2, 1996 | - | - |
| 02001 | 4081083502 | Other | 1 | 2 | $0 | $0 | Oct 25, 1996 | - | - |
| 02002 | 4081.2723 | Other | 1 | 2 | $0 | $0 | Oct 25, 1996 | - | - |
| 02003 | 4081272702 | Other | 1 | 2 | $0 | $0 | Oct 25, 1996 | - | - |
| 02004 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 A02 | Other | 1 | 2 | $0 | $0 | Dec 2, 1996 | - | - |
| 02005 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 VC1 | Other | 1 | 10 | $0 | $0 | Dec 2, 1996 | - | - |
| 02006 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Other | 1 | 1 | $0 | $0 | Dec 2, 1996 | - | - |
| 02007 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Other | 1 | 2 | $0 | $0 | Dec 2, 1996 | - | - |
| 02008 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E B I | Other | 1 | 1 | $0 | $0 | Dec 2, 1996 | - | - |
| 02009 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Other | 1 | 1 | $0 | $0 | Dec 2, 1996 | - | - |
| 02010 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 II | Other | 1 | 1 | $0 | $0 | Dec 2, 1996 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1996 to 2002. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.