Skip to content
SafetyRecord logoSafetyRecord
THOMPSON-MASTER MASONS INC
$569
penalties
8
viol.
3
insp.

THOMPSON-MASTER MASONS INC

CLEAR CREEK SCHOOL, BUFFALO, WY 82834

Inspections
3
Jan 1988 to Dec 2003 · 3 safety, 0 health
Violations
8
across 3 inspections
Penalties on record
$569
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 1Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 16, 2003Planned (H) · Complete scope, Safety#305656704$4695 viol.

Inspection #305656704

Dates

Opened
Dec 16, 2003
Closing Conference Date
Dec 16, 2003
Closed
Feb 26, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,125
Penalties on Record
$469
Site Address
470 W Monkers, Buffalo, WY 82834
Industry
238140 Masonry Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G04 I
Serious27$375$156Dec 17, 2003--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E05 I
Serious17$375$156Dec 17, 2003--
010031926.452
Additional Requirements for Specific Scaffold Types
OSHA citation code: 19260452 C02
Serious37$375$157Dec 17, 2003--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 C02
Other57$0$0Dec 17, 2003--
020021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other27$0$0Dec 17, 2003--
Jul 7, 1997Planned (H) · Complete scope, Safety#125200519$1002 viol.

Inspection #125200519

Dates

Opened
Jul 7, 1997
Closing Conference Date
Jul 7, 1997
Closed
Sep 25, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 repeat
Initial Penalties
$100
Penalties on Record
$100
Site Address
141 S. Main, Buffalo, WY 82834
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Serious44$100$100Jul 7, 1997--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A14
Repeat64$0$0Jul 7, 1997--
Jan 13, 1988Planned (H) · Complete scope, Safety#105792501$01 viol.

Inspection #105792501

Dates

Opened
Jan 13, 1988
Closing Conference Date
Jan 13, 1988
Closed
Feb 3, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Clear Creek School, Buffalo, WY 82834
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001CO120002
OSHA citation code: CO120002 D03
Other11$0$0Feb 5, 1988--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements5 citations · $412
1926.405Electrical - Wiring Methods (Construction)1 citation · $0
1926.452Additional Requirements for Specific Scaffold Types1 citation · $157

Industry comparison

BLS 2024 survey: masonry contractors reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 15.2%; NAICS 23814 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in BUFFALO, WY

All employers in BUFFALO →