Skip to content
SafetyRecord logoSafetyRecord
DANA CORPORATION SPICER CLUTCH DIVISION
$36,825
penalties
60
viol.
3
insp.

DANA CORPORATION SPICER CLUTCH DIVISION

201 BRANDON STREET, AUBURN, IN 46706

Inspections
3
Mar 1987 to Jan 1997 · 3 safety, 0 health
Violations
60
across 3 inspections
Penalties on record
$36,825
latest amounts in DOL records
By classification
Serious 23Willful 0Repeat 15Other 22

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 2, 1997Complaint (B) · Partial scope, Safety#125377689$22,2504 viol.

Inspection #125377689

Dates

Opened
Jan 2, 1997
Closing Conference Date
Jan 6, 1997
Closed
Mar 21, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
542
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$42,000
Penalties on Record
$22,250
Site Address
201 Brandon Street, Auburn, IN 46706
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious330$3,500$1,750Mar 11, 1997--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 III
Serious330$3,500$1,750Feb 26, 1997--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Repeat330$35,000$18,750Mar 11, 1997--
030011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D03
Other11$0$0Apr 18, 1997--
Mar 9, 1995Planned (H) · Complete scope, Safety#124007543$12,62519 viol.

Inspection #124007543

Dates

Opened
Mar 9, 1995
Closing Conference Date
Mar 14, 1995
Closed
May 8, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
585

Violations and Penalties

Total Violations
19
Violation Types
14 serious, 5 other-than-serious
Initial Penalties
$27,150
Penalties on Record
$12,625
Site Address
201 Brandon Street, Auburn, IN 46706
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious117$1,500$750Apr 25, 1995--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious130$4,500$2,250Apr 25, 1995--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious1100$0$0Apr 25, 1995--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious160$0$0Apr 25, 1995--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious82$1,875$935Apr 25, 1995--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious412$4,500$2,250Apr 25, 1995--
01005A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious112$1,875$935Apr 25, 1995--
01005B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious112$0$0Apr 25, 1995--
01006A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious210$1,500$750Apr 11, 1995--
01006B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious310$0$0Apr 11, 1995--
010071910.217
Mechanical Power Presses
OSHA citation code: 19100217 B07 VA
Serious130$1,875$935Apr 25, 1995--
010081910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious230$4,500$2,250Apr 25, 1995--
010091910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious46$1,875$935Apr 25, 1995--
010101910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious130$1,275$635Apr 12, 1995--
010111910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 I02 I
Other17$1,875$0Apr 11, 1995--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other120$0$0Apr 25, 1995--

Showing the 16 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 6, 1987Planned (H) · Complete scope, Safety#2705952$1,95037 viol.

Inspection #2705952

Dates

Opened
Mar 6, 1987
Closing Conference Date
Mar 26, 1987
Contested
Jun 11, 1987
Closed
Oct 30, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
402

Violations and Penalties

Total Violations
37
Violation Types
7 serious, 14 repeat, 16 other-than-serious
Initial Penalties
$6,500
Penalties on Record
$1,950
Site Address
201 Brandon Street, Auburn, IN 46706
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Enforcement Outcome

Citation contest activity appears on Jun 11, 1987. Final orders are recorded through Jul 10, 1987. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

Violation list (16 of 37 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E06 I
Serious424$300$90Jun 9, 1987Jun 11, 1987Jul 10, 1987
010021910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious824$300$90Jun 9, 1987Jun 11, 1987Jul 10, 1987
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M12
Serious13$300$90Jun 9, 1987Jun 11, 1987Jul 10, 1987
010041910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Serious218$300$90May 27, 1987Jun 11, 1987Jul 10, 1987
010051910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious554$300$90Jun 9, 1987Jun 11, 1987Jul 10, 1987
010071910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious929$300$90Sep 30, 1987Jun 11, 1987Jul 10, 1987
010081910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious12$300$90May 11, 1987Jun 11, 1987Jul 10, 1987
020011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 I
Repeat15$600$180Jun 9, 1987Jun 11, 1987Jul 10, 1987
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat225$600$180Jun 9, 1987Jun 11, 1987Jul 10, 1987
020031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Repeat13$600$180Jun 9, 1987Jun 11, 1987Jul 10, 1987
020041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Repeat24$600$180Jun 1, 1987Jun 11, 1987Jul 10, 1987
020051910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q02
Repeat222$200$60Jun 1, 1987Jun 11, 1987Jul 10, 1987
020061910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Repeat13$200$60Jun 9, 1987Jun 11, 1987Jul 10, 1987
020071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Repeat425$200$60May 11, 1987Jun 11, 1987Jul 10, 1987
020081910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Repeat324$200$60May 11, 1987Jun 11, 1987Jul 10, 1987
020091910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Repeat11$200$60May 11, 1987Jun 11, 1987Jul 10, 1987

Showing the 16 violations listed first by citation identifier. This inspection has 37 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)8 citations · $24,225
1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $695
1910.303Electrical - General Requirements5 citations · $180

Other inspected employers in AUBURN, IN

All employers in AUBURN →