Skip to content
SafetyRecord logoSafetyRecord
SUNRISE FIBERGLASS CORPORATION
$4,575
penalties
45
viol.
10
insp.

SUNRISE FIBERGLASS CORPORATION

26467 FALLBROOK AVE, WYOMING, MN 55092

Inspections
10
Jul 1984 to Dec 2011 · 7 safety, 3 health
Violations
45
across 10 inspections
Penalties on record
$4,575
latest amounts in DOL records
By classification
Serious 30Willful 0Repeat 1Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 13, 2011Planned (H) · Complete scope, Safety#316219286$2801 viol.

Inspection #316219286

Dates

Opened
Dec 13, 2011
Closing Conference Date
Dec 13, 2011
Closed
Jan 20, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
34

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$400
Penalties on Record
$280
Site Address
5175 260th St, Wyoming, MN 55092
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 G01 IA
Serious12$400$280Jan 3, 2012--
Aug 20, 2008Planned (H) · Complete scope, Health#312510506$7004 viol.

Inspection #312510506

Dates

Opened
Aug 20, 2008
Closing Conference Date
Sep 16, 2008
Closed
Feb 2, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$1,000
Penalties on Record
$700
Site Address
5175 260th. St., P.o. Box 606, Wyoming, MN 55092
Industry
325211 Plastics Material and Resin Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Serious11$600$420Jan 30, 2009--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Jan 30, 2009--
01002A1910.1000
Air Contaminants
OSHA citation code: 19101000 A03
Serious11$400$280Jan 30, 2009--
01002B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Jan 30, 2009--
Sep 27, 2005Planned (H) · Complete scope, Safety#309478717$2802 viol.

Inspection #309478717

Dates

Opened
Sep 27, 2005
Closing Conference Date
Sep 27, 2005
Closed
Oct 25, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$400
Penalties on Record
$280
Site Address
5175 260th. St., P.o. Box 606, Wyoming, MN 55092
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious11$200$140Nov 1, 2005--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 D
Serious11$200$140Oct 17, 2005--
Sep 6, 2002Planned (H) · Complete scope, Safety#305873085$8758 viol.

Inspection #305873085

Dates

Opened
Sep 6, 2002
Closing Conference Date
Sep 6, 2002
Closed
Nov 20, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$1,250
Penalties on Record
$875
Site Address
5175 260th. St., P.o. Box 606, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 D04 IV
Serious11$150$105Nov 7, 2002--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B01
Serious11$150$105Nov 7, 2002--
010031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B03
Serious21$200$140Nov 7, 2002--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 B03
Serious21$150$105Oct 23, 2002--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$150$105Nov 7, 2002--

Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 21, 1996Planned (H) · Complete scope, Health#126562750$2,03014 viol.

Inspection #126562750

Dates

Opened
Feb 21, 1996
Closing Conference Date
Feb 25, 1996
Closed
Aug 26, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
36

Violations and Penalties

Total Violations
14
Violation Types
13 serious, 1 other-than-serious
Initial Penalties
$2,900
Penalties on Record
$2,030
Site Address
26467 Fallbrook Avenue, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Hexamethylene Diisocyanate Biuret30mg/m³
Toluene-2,4-Diisocyanate (TDI)30.0025 - 0.011mg/m³
Toluene-2,6-Diisocyanate30.0039 - 0.0154mg/m³

Violations

Violation list (5 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 B04
Serious220$300$210May 21, 1996--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 F05
Serious120$300$210May 26, 1996--
010031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 I05
Serious15$400$280May 26, 1996--
010041910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IIB
Serious120$300$210May 21, 1996--
01005A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious120$400$280May 26, 1996--

Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

May 3, 1990Referral (C) · Partial scope, Health#111610119$02 viol.

Inspection #111610119

Dates

Opened
May 3, 1990
Closing Conference Date
Jun 4, 1990
Closed
Apr 2, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
26467 Fallbrook Avenue, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 C 6 I
Other34$0$0Aug 13, 1990--
010021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B 1
Other34$0$0Jun 1, 1991--
Dec 27, 1989Planned (H) · Complete scope, Safety#107735417$1144 viol.

Inspection #107735417

Dates

Opened
Dec 27, 1989
Closing Conference Date
Dec 27, 1989
Closed
Feb 12, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$114
Penalties on Record
$114
Site Address
26467 Fallbrook Avenue, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D 1
Serious11$114$114Feb 26, 1990--
020011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F 5 V
Other11$0$0Feb 26, 1990--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 F 3
Other11$0$0Feb 26, 1990--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G 2
Other11$0$0Feb 26, 1990--
Nov 24, 1986Follow-Up (F) · Partial scope, Safety#104579644$00 viol.

Inspection #104579644

Dates

Opened
Nov 24, 1986
Closing Conference Date
Nov 24, 1986
Closed
Dec 1, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
26467 Fallbrook Avenue, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 8, 1986Planned (H) · Complete scope, Safety#104537287$2207 viol.

Inspection #104537287

Dates

Opened
Oct 8, 1986
Closing Conference Date
Oct 8, 1986
Closed
Nov 24, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
7
Violation Types
1 serious, 1 repeat, 5 other-than-serious
Initial Penalties
$220
Penalties on Record
$220
Site Address
26467 Fallbrook Avenue, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H 1
Serious21$87$87Nov 17, 1986--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A 5
Repeat11$133$133Oct 23, 1986--
030011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H 3
Other11$0$0Nov 17, 1986--
030021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H 4
Other11$0$0Nov 17, 1986--
030031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A 4
Other11$0$0Nov 17, 1986--

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 3, 1984Complaint (B) · Partial scope, Safety#14893556$763 viol.

Inspection #14893556

Dates

Opened
Jul 3, 1984
Closing Conference Date
Jul 3, 1984
Closed
Aug 16, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
36
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$76
Penalties on Record
$76
Site Address
26467 Fallbrook Ave, Wyoming, MN 55092
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A5
Serious11$76$76Jul 30, 1984--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G2
Other11$0$0Aug 13, 1984--
020021910.94
Ventilation
OSHA citation code: 19100094 C6 I
Other22$0$0Aug 13, 1984--
Inspections 1 to 10 of 10, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1000Air Contaminants6 citations · $980
1910.107Spray Finishing Using Flammable and Combustible Materials6 citations · $245
1910.134Respiratory Protection6 citations · $560

Chemical exposure sampling

Samples
9
Substances
3
Inspections
1

Other inspected employers in WYOMING, MN