ACCURATE PARTITIONS CORP.
8000 JOLIET ROAD, MCCOOK, IL 60525
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 25, 2011#315154716Jan 25, 2011Complaint (B) · Partial scope, Health#315154716$8,0006 viol.6 violations$8,000 in penalties
Inspection #315154716
Dates
- Opened
- Jan 25, 2011
- Closing Conference Date
- Mar 31, 2011
- Closed
- Feb 21, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 72
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 6 serious
- Initial Penalties
- $16,100
- Penalties on Record
- $8,000
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- 337215 Showcase, Partition, Shelving, and Locker Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling3 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Chromic Acid and Chromates (as CrO3) | 3 | 0 | mg/m³ |
| Chromium (VI) - TWA | 3 | 0 | mg/m³ |
| Gravimetric DeterminationQC | 6 | 0.818 - 20.8058 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 6 | 0.818 - 20.8058 | mg/m³ |
| Sample WeightQC | 6 | 0.363 - 9.507 | mg |
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 1 | 46 | $3,500 | $1,750 | May 19, 2011 | - | - |
| 01002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C | Serious | 1 | 6 | $2,100 | $1,050 | May 19, 2011 | - | - |
| 01003 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 B02 III | Serious | 1 | 6 | $2,100 | $1,050 | May 19, 2011 | - | - |
| 01004 | 1910.307 Electrical - Hazardous (Classified) Locations OSHA citation code: 19100307 B | Serious | 1 | 46 | $3,500 | $1,750 | May 19, 2011 | - | - |
| 01005 | 1910.1026 Chromium (VI) OSHA citation code: 19101026 D01 | Serious | 1 | 2 | $2,800 | $1,400 | Apr 7, 2011 | - | - |
| 01006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Serious | 1 | 6 | $2,100 | $1,000 | May 19, 2011 | - | - |
Jan 25, 2011#315154682Jan 25, 2011Complaint (B) · Partial scope, Safety#315154682$8,75012 viol.12 violations$8,750 in penalties
Inspection #315154682
Dates
- Opened
- Jan 25, 2011
- Closing Conference Date
- Jan 28, 2011
- Closed
- May 26, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 62
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 10 serious, 2 other-than-serious
- Initial Penalties
- $17,500
- Penalties on Record
- $8,750
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- 339999 All Other Miscellaneous Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (6 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C05 I | Serious | 1 | 12 | $4,900 | $2,450 | May 19, 2011 | - | - |
| 01001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 30 | $0 | $0 | May 19, 2011 | - | - |
| 01001C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 IA | Serious | 1 | 20 | $0 | $0 | May 19, 2011 | - | - |
| 01002 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L01 I | Serious | 1 | 30 | $3,500 | $1,750 | May 19, 2011 | - | - |
| 01003A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 12 | 40 | $3,500 | $1,750 | May 19, 2011 | - | - |
| 01003B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 4 | 30 | $0 | $0 | May 19, 2011 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jun 18, 1998#122159114Jun 18, 1998Planned (H) · Complete scope, Health#122159114$2,7505 viol.5 violations$2,750 in penalties
Inspection #122159114
Dates
- Opened
- Jun 18, 1998
- Closing Conference Date
- Jun 19, 1998
- Closed
- Aug 14, 1998
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 87
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $5,500
- Penalties on Record
- $2,750
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 1 | 5 | $2,500 | $0 | Sep 15, 1998 | - | - |
| 01001B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 5 | $0 | $0 | Jul 31, 1998 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 5 | $1,250 | $1,000 | Aug 6, 1998 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B03 I | Serious | 1 | 1 | $1,750 | $1,750 | Jul 16, 1998 | - | - |
| 02001 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 II | Other | 1 | 3 | $0 | $0 | Jul 26, 1998 | - | - |
Nov 1, 1995#108731506Nov 1, 1995Follow-Up (F) · Partial scope, Safety#108731506$2,6003 viol.3 violations$2,600 in penalties
Inspection #108731506
Dates
- Opened
- Nov 1, 1995
- Closing Conference Date
- Nov 1, 1995
- Closed
- Mar 1, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 95
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 2 repeat
- Initial Penalties
- $6,000
- Penalties on Record
- $2,600
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B01 | Serious | 1 | 4 | $1,200 | $200 | Nov 27, 1995 | - | - |
| 02001 | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Repeat | 1 | 10 | $2,400 | $1,200 | Nov 28, 1995 | - | - |
| 02002 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B02 IV | Repeat | 2 | 10 | $2,400 | $1,200 | Nov 28, 1995 | - | - |
Nov 21, 1994#108726340Nov 21, 1994Complaint (B) · Partial scope, Health#108726340$8,00010 viol.10 violations$8,000 in penalties
Inspection #108726340
Dates
- Opened
- Nov 21, 1994
- Closing Conference Date
- Dec 1, 1994
- Closed
- Mar 1, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 90
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 9 serious, 1 other-than-serious
- Initial Penalties
- $11,550
- Penalties on Record
- $8,000
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (6 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.38 Emergency Action Plans OSHA citation code: 19100038 A01 | Serious | 1 | 90 | $1,050 | $1,000 | Jan 23, 1995 | - | - |
| 01002 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Serious | 3 | 15 | $2,450 | $2,000 | Feb 15, 1995 | - | - |
| 01003A | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Serious | 1 | 2 | $1,050 | $1,000 | Dec 23, 1994 | - | - |
| 01003B | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B02 IV | Serious | 1 | 2 | $0 | $0 | Dec 23, 1994 | - | - |
| 01004 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 4 | $1,050 | $1,000 | Jan 4, 1996 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $1,750 | $1,000 | Mar 15, 1995 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Failure to Abate Penalties2 citations, $7,000 in FTA penalties on record
OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 2 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.
| Citation | FTA Inspection | FTA Issuance | FTA Penalty | FTA Contest | FTA Final Order |
|---|---|---|---|---|---|
| 01004 | #108731506 | Nov 21, 1995 | $6,000 | - | - |
Showing the 1 FTA rows present in the first 6 citations on this inspection. OSHA's record shows 2 total citations with FTA activity for this inspection. The complete list is available at enforcedata.dol.gov.
Jan 30, 1989#103270708Jan 30, 1989Planned (H) · Complete scope, Safety#103270708$1,3007 viol.7 violations$1,300 in penalties
Inspection #103270708
Dates
- Opened
- Jan 30, 1989
- Closing Conference Date
- Jan 30, 1989
- Closed
- Mar 16, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 70
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 6 serious, 1 other-than-serious
- Initial Penalties
- $1,980
- Penalties on Record
- $1,300
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Serious | 1 | 2 | $270 | $150 | Mar 3, 1989 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A02 | Serious | 1 | 2 | $360 | $250 | Mar 3, 1989 | - | - |
| 01003 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F01 I | Serious | 1 | 1 | $360 | $250 | Feb 12, 1989 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 2 | 2 | $360 | $250 | Mar 3, 1989 | - | - |
| 01005 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 A02 | Serious | 1 | 1 | $270 | $150 | Feb 12, 1989 | - | - |
| 01006 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 J04 IIA | Serious | 1 | 2 | $360 | $250 | Mar 3, 1989 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 9, 1986#100155258Jan 9, 1986Follow-Up (F) · Partial scope, Safety#100155258$8002 viol.2 violations$800 in penalties
Inspection #100155258
Dates
- Opened
- Jan 9, 1986
- Closing Conference Date
- Jan 9, 1986
- Contested
- Apr 16, 1986
- Final Order
- Jul 17, 1986
- Closed
- Mar 9, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 repeat
- Initial Penalties
- $900
- Penalties on Record
- $800
- Site Address
- 8000 Joliet Road, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B03 | Repeat | 1 | 3 | $360 | $300 | Apr 21, 1986 | Apr 16, 1986 | Jul 17, 1986 |
| 01002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C06 | Repeat | 1 | 1 | $540 | $500 | Apr 21, 1986 | Apr 16, 1986 | Jul 17, 1986 |
Apr 19, 1985#1267103Apr 19, 1985Planned (H) · Complete scope, Safety#1267103$1,12513 viol.13 violations$1,125 in penalties
Inspection #1267103
Dates
- Opened
- Apr 19, 1985
- Closing Conference Date
- Apr 24, 1985
- Closed
- Jun 26, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 73
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 9 serious, 4 other-than-serious
- Initial Penalties
- $2,190
- Penalties on Record
- $1,125
- Site Address
- 8000 Joliet Rd, Mccook, IL 60525
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D04 I | Serious | 1 | 2 | $100 | $100 | Jul 10, 1985 | - | - |
| 01002A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C01 I | Serious | 1 | 1 | $350 | $175 | May 30, 1985 | - | - |
| 01002B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 I | Serious | 1 | 1 | $0 | $0 | May 30, 1985 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 I | Serious | 1 | 1 | $350 | $350 | Jun 30, 1985 | - | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 III | Serious | 1 | 1 | $350 | $0 | Jun 30, 1985 | - | - |
| 01005 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 E01 I | Serious | 1 | 10 | $640 | $200 | May 30, 1985 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1985 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.