May 14, 2026Planned (H) · Partial scope, Safety#348935495$2,3506 viol.

Inspection #348935495

Dates

Opened
May 14, 2026
Closing Conference Date
May 14, 2026
Final Order
Jun 19, 2026
Closed
Jun 19, 2026

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
29

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$4,450
Penalties on Record
$2,350
Site Address
1193 400 West, Salt Lake City, UT 84101
Industry
333514 Special Die and Tool, Die Set, Jig, and Fixture Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious129$4,200$2,100Jul 6, 2026-Jun 19, 2026
01001B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious11$0$0Jul 6, 2026-Jun 19, 2026
020011904.41
Electronic Submission of Records
OSHA citation code: 19040041 A01 I
Other11$250$250Jul 6, 2026-Jun 19, 2026
02002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other129$0$0Jul 6, 2026-Jun 19, 2026
02002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Other11$0$0Jul 6, 2026-Jun 19, 2026
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other129$0$0-Jun 19, 2026
Nov 21, 1995Planned (H) · Complete scope, Health#126752161$010 viol.

Inspection #126752161

Dates

Opened
Nov 21, 1995
Closing Conference Date
Nov 28, 1995
Closed
Jan 16, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
10
Violation Types
10 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other110$0$0Jan 15, 1996--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other11$0$0Jan 15, 1996--
010031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Other110$0$0Jan 15, 1996--
010041910.184
Slings
OSHA citation code: 19100184 I09
Other11$0$0Jan 15, 1996--
010051910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other11$0$0Jan 15, 1996--
010061910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other11$0$0Jan 15, 1996--

Showing the 6 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 18, 1990Follow-Up (F) · Partial scope, Safety#105610984$00 viol.

Inspection #105610984

Dates

Opened
Oct 18, 1990
Closing Conference Date
Oct 18, 1990
Closed
Nov 5, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 28, 1990Planned (H) · Complete scope, Safety#105610836$09 viol.

Inspection #105610836

Dates

Opened
Jun 28, 1990
Closing Conference Date
Jun 28, 1990
Closed
Nov 5, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Other12$0$0Sep 3, 1990--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other13$0$0Sep 3, 1990--
010031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other12$0$0Sep 3, 1990--
010041910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other44$0$0Sep 3, 1990--
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other11$0$0Aug 9, 1990--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Other12$0$0Aug 3, 1990--

Showing the 6 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Sep 29, 1987Follow-Up (F) · Partial scope, Safety#105590343$00 viol.

Inspection #105590343

Dates

Opened
Sep 29, 1987
Closing Conference Date
Sep 29, 1987
Closed
Dec 30, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
42

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jul 10, 1987Planned (H) · Complete scope, Safety#105583108$09 viol.

Inspection #105583108

Dates

Opened
Jul 10, 1987
Closing Conference Date
Jul 10, 1987
Closed
Jul 28, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
43

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001GEN00220401Other12$0$0Aug 28, 1987--
01002GEN0106040400001Other12$0$0Aug 28, 1987--
01003GEN02130203Other22$0$0Aug 28, 1987--
01004GEN02130301Other12$0$0Aug 28, 1987--
01005GEN02150209Other24$0$0Aug 28, 1987--
01006GEN0219050100001Other12$0$0Aug 28, 1987--

Showing the 6 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 23, 1973Follow-Up (F) · Complete scope, Safety#217911999$00 viol.

Inspection #217911999

Dates

Opened
Aug 23, 1973
Closing Conference Date
Aug 23, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
18

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 24, 1973Planned (H) · Complete scope, Safety#217913714$503 viol.

Inspection #217913714

Dates

Opened
May 24, 1973
Closing Conference Date
May 24, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
18

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$50
Penalties on Record
$50
Site Address
1193 South 400 West, Salt Lake City, UT 84101
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other3-$25$25Jul 30, 1973--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other1-$0$0Jul 30, 1973--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$25$25Jul 2, 1973--
Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)5 citations · $2,125
1910.1200Hazard Communication4 citations · $0
1910.219Mechanical Power-Transmission Apparatus3 citations · $25

Industry comparison

BLS 2024 survey: special die and tool, die set, jig, and fixture manufacturing reported 2.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 14.7%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Salt Lake City, UT