EATON HYDRAULICS LLC
2425 W MICHIGAN AVE, JACKSON, MI 49202
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 11, 2012#312010325May 11, 2012Complaint (B) · Partial scope, Health#312010325$9807 viol.7 violations$980 in penalties
Inspection #312010325
Dates
- Opened
- May 11, 2012
- Closing Conference Date
- Jul 2, 2012
- Closed
- Oct 10, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 107
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 3 serious, 4 other-than-serious
- Initial Penalties
- $3,200
- Penalties on Record
- $980
- Site Address
- 2425 W Michigan Ave, Jackson, MI 49202
- Industry
- 333996 Fluid Power Pump and Motor Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 3254720103 | Serious | 1 | 1 | $2,000 | $560 | Aug 13, 2012 | - | - |
| 01001B | 3255146403 | Serious | 1 | 1 | $0 | $0 | Aug 13, 2012 | - | - |
| 01001C | 3256000801 | Serious | 1 | 1 | $0 | $0 | Aug 23, 2012 | - | - |
| 01002A | 3255145501 | Other | 1 | 1 | $1,200 | $420 | Aug 13, 2012 | - | - |
| 01002B | 3255147206 | Other | 1 | 1 | $0 | $0 | Sep 17, 2012 | - | - |
| 01002C | 1910.1026 Chromium (VI) OSHA citation code: 19101026 D01 | Other | 1 | 1 | $0 | $0 | Aug 13, 2012 | - | - |
| 01002D | 1910.1026 Chromium (VI) OSHA citation code: 19101026 L02 I | Other | 1 | 1 | $0 | $0 | Sep 17, 2012 | - | - |
Jul 11, 2001#127040509Jul 11, 2001Planned (H) · Complete scope, Safety#127040509$1,65221 viol.21 violations$1,652 in penalties
Inspection #127040509
Dates
- Opened
- Jul 11, 2001
- Closing Conference Date
- Jul 16, 2001
- Contested
- Nov 21, 2001
- Closed
- Aug 13, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 163
Violations and Penalties
- Total Violations
- 21
- Violation Types
- 4 serious, 17 other-than-serious
- Initial Penalties
- $3,300
- Penalties on Record
- $1,652
- Site Address
- 2425 W Michigan Ave, Jackson, MI 49202
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Enforcement Outcome
Citation contest activity appears on Nov 21, 2001. Final orders are recorded through Jun 9, 2002. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Violations
Violation list (21 of 21 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 4081273001 | Serious | 1 | 1 | $825 | $413 | Oct 5, 2001 | - | - |
| 01002 | 4081330801 | Serious | 1 | 4 | $825 | $413 | Nov 13, 2001 | - | - |
| 01003 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C01 | Serious | 1 | 2 | $825 | $413 | Oct 5, 2001 | - | - |
| 01004 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 I | Serious | 1 | 2 | $825 | $413 | Oct 5, 2001 | - | - |
| 02001 | 4081003301 | Other | 1 | 1 | $0 | $0 | Oct 5, 2001 | - | - |
| 02002 | 4081003601 | Other | 1 | 1 | $0 | $0 | Oct 5, 2001 | - | - |
| 02003 | 4081018701 | Other | 1 | 1 | $0 | $0 | Nov 13, 2001 | - | - |
| 02004 | 4081021502 | Other | 1 | 2 | $0 | $0 | Oct 5, 2001 | - | - |
| 02005 | 4081187201 | Other | 1 | 4 | $0 | $0 | Nov 13, 2001 | - | - |
| 02006 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 4 | 4 | $0 | $0 | Nov 13, 2001 | - | - |
| 02007 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Other | 3 | 3 | $0 | $0 | Nov 13, 2001 | - | - |
| 02008 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A01 I | Other | 1 | 2 | $0 | $0 | Oct 5, 2001 | - | - |
| 02009 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Other | 1 | 2 | $0 | $0 | Nov 13, 2001 | - | - |
| 02010 | 4081400403 | Other | 1 | 2 | $0 | $0 | Nov 13, 2001 | - | - |
| 02011 | 4081400703 | Other | 1 | 10 | $0 | $0 | Nov 13, 2001 | - | - |
| 02012 | 4081400707 | Other | 2 | 2 | $0 | $0 | Nov 13, 2001 | - | - |
| 02013 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Other | 1 | 10 | $0 | $0 | Mar 1, 2002 | Nov 21, 2001 | Jun 9, 2002 |
| 02014 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Other | 1 | 10 | $0 | $0 | Oct 5, 2001 | - | - |
| 02015 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C02 | Other | 1 | 2 | $0 | $0 | Oct 5, 2001 | - | - |
| 02016 | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C03 | Other | 1 | 2 | $0 | $0 | Oct 5, 2001 | - | - |
| 02017 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 | Other | 1 | 4 | $0 | $0 | Oct 5, 2001 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 2001 to 2012. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Industry comparison
BLS 2024 survey: fluid power pump and motor manufacturing reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source