BUSTIN INDUSTRIAL PRODUCTS INC.
PO BOX 388-SPRUCE & OAK STREET, EAST STROUDSBURG, PA 18301
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Apr 18, 2002#303348767Apr 18, 2002Planned (H) · Complete scope, Health#303348767$7324 viol.4 violations$732 in penalties
Inspection #303348767
Dates
- Opened
- Apr 18, 2002
- Closing Conference Date
- Apr 29, 2002
- Closed
- May 30, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $1,125
- Penalties on Record
- $732
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 1 | $375 | $244 | Jun 5, 2002 | - | - |
| 01002 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 1 | $375 | $244 | Jun 5, 2002 | - | - |
| 01003A | 1910.134 Respiratory Protection OSHA citation code: 19100134 E01 | Serious | 1 | 1 | $375 | $244 | Jun 5, 2002 | - | - |
| 01003B | 1910.134 Respiratory Protection OSHA citation code: 19100134 F01 | Serious | 1 | 1 | $0 | $0 | Jun 5, 2002 | - | - |
Apr 15, 2002#110027141Apr 15, 2002Planned (H) · Complete scope, Safety#110027141$2,9759 viol.9 violations$2,975 in penalties
Inspection #110027141
Dates
- Opened
- Apr 15, 2002
- Closing Conference Date
- May 14, 2002
- Closed
- Dec 23, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 5 serious, 4 other-than-serious
- Initial Penalties
- $5,600
- Penalties on Record
- $2,975
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | 4 | $1,225 | $775 | Jun 12, 2002 | - | - |
| 01002 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 2 | 2 | $1,225 | $700 | Jun 12, 2002 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 6 | 5 | $1,225 | $700 | Nov 16, 2002 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Serious | 1 | 5 | $875 | $450 | May 30, 2002 | - | - |
| 01005 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B06 I | Serious | 1 | 2 | $700 | $350 | Jun 3, 2002 | - | - |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Other | 1 | 10 | $0 | $0 | Jul 8, 2002 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jul 20, 1999#301044566Jul 20, 1999Planned (H) · No Inspection scope, Health#301044566$00 viol.0 violations$0 in penalties
Inspection #301044566
Dates
- Opened
- Jul 20, 1999
- Closing Conference Date
- Not recorded
- Closed
- Sep 1, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Not recorded
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Sep 23, 1997#301038048Sep 23, 1997Planned (H) · Complete scope, Health#301038048$1,0008 viol.8 violations$1,000 in penalties
Inspection #301038048
Dates
- Opened
- Sep 23, 1997
- Closing Conference Date
- Oct 6, 1997
- Closed
- Dec 16, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 4 serious, 4 other-than-serious
- Initial Penalties
- $1,575
- Penalties on Record
- $1,000
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 I | Serious | 3 | 10 | $525 | $350 | Nov 3, 1997 | - | - |
| 01001B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B04 III | Serious | 1 | 10 | $0 | $0 | Nov 15, 1997 | - | - |
| 01002 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B08 III | Serious | 1 | 10 | $525 | $325 | Dec 3, 1997 | - | - |
| 01003 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 B07 VA | Serious | 1 | 10 | $525 | $325 | Dec 3, 1997 | - | - |
| 02001 | 1910.144 Safety Color Code for Marking Physical Hazards OSHA citation code: 19100144 A01 III | Other | 1 | 10 | $0 | $0 | Nov 3, 1997 | - | - |
| 02002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 1 | 10 | $0 | $0 | Nov 3, 1997 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 17, 1994#17621665May 17, 1994Planned (H) · Complete scope, Safety#17621665$1,8754 viol.4 violations$1,875 in penalties
Inspection #17621665
Dates
- Opened
- May 17, 1994
- Closing Conference Date
- Jun 6, 1994
- Closed
- Oct 6, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 45
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 2 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $1,875
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $2,500 | $1,250 | Sep 1, 1994 | - | - |
| 01002 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 2 | $750 | $375 | Jul 20, 1994 | - | - |
| 02001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 E01 IV | Other | 1 | 2 | $500 | $250 | Jul 20, 1994 | - | - |
| 02002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 2 | $0 | $0 | Sep 1, 1994 | - | - |
Jun 2, 1989#625483Jun 2, 1989Planned (H) · Complete scope, Safety#625483$754 viol.4 violations$75 in penalties
Inspection #625483
Dates
- Opened
- Jun 2, 1989
- Closing Conference Date
- Jun 15, 1989
- Contested
- Sep 12, 1989
- Closed
- Apr 7, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 54
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 serious, 3 other-than-serious
- Initial Penalties
- $200
- Penalties on Record
- $75
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Enforcement Outcome
Citation contest activity appears on Sep 12, 1989. Final orders are recorded through Feb 28, 1990. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IIB2 | Serious | 1 | 2 | $200 | $75 | Aug 22, 1989 | Sep 12, 1989 | Feb 28, 1990 |
| 02001 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 III | Other | 1 | 2 | $0 | $0 | Aug 22, 1989 | - | - |
| 02002 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 J02 IV | Other | 1 | 2 | $0 | $0 | Aug 22, 1989 | - | - |
| 02003 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 20 | $0 | $0 | Sep 1, 1989 | - | - |
Feb 28, 1989#18221820Feb 28, 1989Complaint (B) · Partial scope, Health#18221820$752 viol.2 violations$75 in penalties
Inspection #18221820
Dates
- Opened
- Feb 28, 1989
- Closing Conference Date
- Mar 2, 1989
- Closed
- Sep 12, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 60
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $200
- Penalties on Record
- $75
- Site Address
- 401 Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 7 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 7 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 7 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 7 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 | mg/m³ |
| Copper Fume (as Cu) | 7 | 0 | mg/m³ |
| Iron Oxide Fume | 7 | 0 - 5.2747 | mg/m³ |
| Lead, Inorganic (as Pb) | 7 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 7 | 0 - 0.3465 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 7 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 6 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 7 | 0 | mg/m³ |
| Zinc Oxide Fume | 7 | 0 - 0.0581 | mg/m³ |
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 VII | Serious | 1 | 2 | $200 | $75 | Jun 12, 1989 | - | - |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 40 | $0 | $0 | Apr 29, 1989 | - | - |
Mar 1, 1979#13009105Mar 1, 1979Complaint (B) · Complete scope, Safety#13009105$6,72011 viol.11 violations$6,720 in penalties
Inspection #13009105
Dates
- Opened
- Mar 1, 1979
- Closing Conference Date
- Jun 13, 1979
- Contested
- Aug 15, 1979
- Closed
- Dec 12, 1980
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 10
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 8 serious, 1 willful, 2 other-than-serious
- Initial Penalties
- $6,720
- Penalties on Record
- $6,720
- Site Address
- Po Box 388-Spruce & Oak Street, East Stroudsburg, PA 18301
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (6 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | - | $400 | $400 | Aug 12, 1979 | Aug 15, 1979 | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | - | $240 | $240 | Oct 12, 1979 | Aug 15, 1979 | - |
| 01003 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | - | $200 | $200 | Aug 12, 1979 | Aug 15, 1979 | - |
| 01004 | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 2 | - | $240 | $240 | Aug 12, 1979 | Aug 15, 1979 | - |
| 01005 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 B01 | Serious | 1 | - | $160 | $160 | Aug 12, 1979 | Aug 15, 1979 | - |
| 01006 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | - | $120 | $120 | Aug 12, 1979 | Aug 15, 1979 | - |
Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1979 to 2002. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.