Skip to content
SafetyRecord logoSafetyRecord
JOVAL MANUFACTURING CO., INC.
$9,726
penalties
25
viol.
4
insp.

JOVAL MANUFACTURING CO., INC.

120 IRIS AVENUE, JEFFERSON, LA 70121

Inspections
4
Dec 1986 to Feb 2019 · 4 safety, 0 health
Violations
25
across 4 inspections
Penalties on record
$9,726
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 21, 2019Planned (H) · Partial scope, Safety#343800314$6,1262 viol.

Inspection #343800314

Dates

Opened
Feb 21, 2019
Closing Conference Date
Feb 21, 2019
Final Order
Apr 4, 2019
Closed
Apr 24, 2019

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
37

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$20,420
Penalties on Record
$6,126
Site Address
120 Iris Ave, Jefferson, LA 70181
Industry
332322 Sheet Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious12$10,210$6,126Mar 25, 2019-Apr 4, 2019
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Other12$10,210$0Mar 25, 2019-Apr 4, 2019
Mar 2, 2007Planned (H) · Partial scope, Safety#309791895$2,55010 viol.

Inspection #309791895

Dates

Opened
Mar 2, 2007
Closing Conference Date
Mar 2, 2007
Closed
May 2, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
10
Violation Types
8 serious, 2 other-than-serious
Initial Penalties
$4,250
Penalties on Record
$2,550
Site Address
120 Iris Ave, Jefferson, LA 70181
Industry
332322 Sheet Metal Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Serious115$750$450Apr 26, 2007--
01002A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious22$2,500$1,500Mar 16, 2007--
01002B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 II
Serious13$0$0Apr 26, 2007--
01002C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious11$0$0Mar 29, 2007--
01003A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A
Serious27$1,000$600Apr 26, 2007--
01003B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious17$0$0Apr 26, 2007--
01003C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B01
Serious27$0$0Apr 26, 2007--
01003D1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01 I
Serious27$0$0Apr 26, 2007--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other12$0$0Apr 5, 2007--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 C02 II
Other17$0$0Apr 5, 2007--
Jul 20, 1998Planned (H) · Partial scope, Safety#301991527$7503 viol.

Inspection #301991527

Dates

Opened
Jul 20, 1998
Closing Conference Date
Jul 20, 1998
Closed
Sep 30, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
35

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,250
Penalties on Record
$750
Site Address
120 Iris St., Jefferson, LA 70181
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious25$375$225Aug 17, 1998--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious15$375$225Aug 19, 1998--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious25$500$300Aug 19, 1998--
Dec 16, 1986Planned (H) · Complete scope, Safety#1381375$30010 viol.

Inspection #1381375

Dates

Opened
Dec 16, 1986
Closing Conference Date
Dec 16, 1986
Closed
Feb 20, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
10
Violation Types
4 serious, 6 other-than-serious
Initial Penalties
$600
Penalties on Record
$300
Site Address
120 Iris Avenue, Jefferson, LA 70121
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious62$200$100Feb 13, 1987--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious32$200$100Jan 26, 1987--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious32$200$100Jan 26, 1987--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious32$0$0Jan 26, 1987--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other120$0$0Jan 26, 1987--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other110$0$0Jan 26, 1987--
020031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Other14$0$0Jan 26, 1987--
020041910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other14$0$0Jan 26, 1987--
020051910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Other42$0$0Jan 26, 1987--
020061910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 II
Other42$0$0Jan 26, 1987--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses6 citations · $550
1910.219Mechanical Power-Transmission Apparatus5 citations · $500
1910.147Control of Hazardous Energy (Lockout/Tagout)5 citations · $7,626

Industry comparison

BLS 2024 survey: sheet metal work manufacturing reported 3.3 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.4%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in JEFFERSON, LA

All employers in JEFFERSON →