DANIT CORP
150 GODDARD MEMORIAL DR, WORCESTER, MA 01603
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Feb 5, 1987#17929803Feb 5, 1987Referral (C) · Partial scope, Health#17929803$00 viol.0 violations$0 in penalties
Inspection #17929803
Dates
- Opened
- Feb 5, 1987
- Closing Conference Date
- Mar 9, 1987
- Closed
- Apr 2, 1987
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 47
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 150 Goodard Memorial Dr., Worcester, MA 01602
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 5 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 6 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 6 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 6 | 0 - 0.1079 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 | mg/m³ |
| Iron Oxide Fume | 6 | 0 - 0.0119 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 6 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 6 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 6 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 | mg/m³ |
Jan 29, 1987#17929696Jan 29, 1987Planned (H) · Complete scope, Safety#17929696$808 viol.8 violations$80 in penalties
Inspection #17929696
Dates
- Opened
- Jan 29, 1987
- Closing Conference Date
- Jan 29, 1987
- Closed
- Oct 7, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 47
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 1 serious, 7 other-than-serious
- Initial Penalties
- $80
- Penalties on Record
- $80
- Site Address
- 150 Goodard Memorial Dr., Worcester, MA 01602
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 9 | 1 | $80 | $80 | Jun 15, 1987 | - | - |
| 02001 | 1910.103 Hydrogen OSHA citation code: 19100103 B01 IVC | Other | 1 | 47 | $0 | $0 | Jun 15, 1987 | - | - |
| 02002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 1 | 1 | $0 | $0 | Apr 15, 1987 | - | - |
| 02003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Other | 1 | 1 | $0 | $0 | Apr 15, 1987 | - | - |
| 02004 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Other | 1 | 1 | $0 | $0 | Mar 9, 1987 | - | - |
| 02005 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 2 | 45 | $0 | $0 | Apr 15, 1987 | - | - |
| 02006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H02 I | Other | 1 | 47 | $0 | $0 | Apr 15, 1987 | - | - |
| 02007 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H02 III | Other | 1 | 47 | $0 | $0 | Apr 15, 1987 | - | - |
Apr 25, 1984#1827609Apr 25, 1984Referral (C) · Partial scope, Health#1827609$4206 viol.6 violations$420 in penalties
Inspection #1827609
Dates
- Opened
- Apr 25, 1984
- Closing Conference Date
- Jun 8, 1984
- Closed
- Oct 16, 1984
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 45
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 5 serious, 1 other-than-serious
- Initial Penalties
- $420
- Penalties on Record
- $420
- Site Address
- 150 Goddard Memorial Dr, Worcester, MA 01603
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling1 substance sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 - 0.76 | mg/m³ |
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 2 | 5 | $420 | $420 | Oct 29, 1984 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 2 | 5 | $0 | $0 | Jul 9, 1984 | - | - |
| 01001C | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 2 | 5 | $0 | $0 | Oct 29, 1984 | - | - |
| 01001D | 1910.134 Respiratory Protection OSHA citation code: 19100134 B01 | Serious | 2 | 5 | $0 | $0 | Jul 9, 1984 | - | - |
| 01001E | 1910.134 Respiratory Protection OSHA citation code: 19100134 B08 | Serious | 2 | 5 | $0 | $0 | Sep 28, 1984 | - | - |
| 02001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Other | 1 | 10 | $0 | $0 | Jun 28, 1984 | - | - |
Mar 23, 1984#142646Mar 23, 1984Planned (H) · Complete scope, Safety#142646$28016 viol.16 violations$280 in penalties
Inspection #142646
Dates
- Opened
- Mar 23, 1984
- Closing Conference Date
- Mar 27, 1984
- Closed
- Oct 23, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 45
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 7 serious, 9 other-than-serious
- Initial Penalties
- $280
- Penalties on Record
- $280
- Site Address
- 150 Goddard Memorial Drive, Worcester, MA 01603
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.106 Flammable Liquids OSHA citation code: 19100106 D02 I | Serious | 1 | 1 | $40 | $40 | May 10, 1984 | - | - |
| 01001B | 1910.106 Flammable Liquids OSHA citation code: 19100106 D05 I | Serious | 1 | 1 | $0 | $0 | Apr 26, 1984 | - | - |
| 01001C | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVC | Serious | 1 | 1 | $0 | $0 | Apr 26, 1984 | - | - |
| 01002A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 2 | $80 | $80 | May 29, 1984 | - | - |
| 01002B | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 8 | 8 | $0 | $0 | Jul 27, 1984 | - | - |
| 01003A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 7 | 7 | $160 | $160 | May 11, 1984 | - | - |
| 01003B | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B01 | Serious | 1 | 1 | $0 | $0 | Apr 26, 1984 | - | - |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Other | 1 | 1 | $0 | $0 | Apr 26, 1984 | - | - |
| 02002 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Other | 1 | 1 | $0 | $0 | Jun 27, 1984 | - | - |
| 02003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C04 I | Other | 1 | 1 | $0 | $0 | Jul 27, 1984 | - | - |
| 02004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 1 | 1 | $0 | $0 | May 10, 1984 | - | - |
| 02005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Other | 2 | 2 | $0 | $0 | May 10, 1984 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1984 to 1987. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.