SOONER FABRICATING & SALES CO INC
$455
penalties
18
viol.
3
insp.

SOONER FABRICATING & SALES CO INC

509 BLDG E N REDBUD, BROKEN ARROW, OK 74012

Inspections
3
Jul 1984 to Mar 1986 · 2 safety, 1 health
Violations
18
across 3 inspections
Penalties on record
$455
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 19, 1986Complaint (B) · Partial scope, Health#100279637$01 viol.

Inspection #100279637

Dates

Opened
Mar 19, 1986
Closing Conference Date
Mar 20, 1986
Closed
Sep 30, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
9836 S 219 E Avenue, Broken Arrow, OK 74013
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)30mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium Fume (as Cd)30mg/m³
Chromium, Metal and Insoluble Salts30mg/m³
Cobalt, Metal, Dust and Fume (as Co)30 - 0.0031mg/m³
Copper Fume (as Cu)30 - 0.0048mg/m³
Iron Oxide Fume30 - 0.8931mg/m³
Lead, Inorganic (as Pb)30mg/m³
Manganese Fume (as Mn)30 - 0.0232mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30mg/m³
Nickel, Metal and Insoluble compounds (as Ni)30mg/m³
Particulates not otherwise regulated (Respirable Fraction)30mg/m³
Vanadium fume (as V2O5)30mg/m³
Zinc Oxide Fume30 - 0.1027mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Other13$0$0Jun 9, 1986--
Mar 19, 1986Complaint (B) · Partial scope, Safety#2463982$2757 viol.

Inspection #2463982

Dates

Opened
Mar 19, 1986
Closing Conference Date
Mar 20, 1986
Closed
Mar 1, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
38
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$550
Penalties on Record
$275
Site Address
9836 South 219 East Avenue, Broken Arrow, OK 74012
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.94
Ventilation
OSHA citation code: 19100094 C04 IV
Serious33$150$75May 20, 1986--
010021910.94
Ventilation
OSHA citation code: 19100094 C05 I
Serious43$150$75May 20, 1986--
010031910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious25$250$125May 1, 1986--
020011910.94
Ventilation
OSHA citation code: 19100094 C07 IIIB
Other13$0$0May 20, 1986--
020021910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 G06 I
Other13$0$0May 20, 1986--
020031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other11$0$0May 1, 1986--
020041910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0May 1, 1986--
Jul 10, 1984Planned (H) · Complete scope, Safety#1432780$18010 viol.

Inspection #1432780

Dates

Opened
Jul 10, 1984
Closing Conference Date
Jul 11, 1984
Closed
Feb 4, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
10
Violation Types
6 serious, 4 other-than-serious
Initial Penalties
$180
Penalties on Record
$180
Site Address
509 Bldg E N Redbud, Broken Arrow, OK 74012
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious12$60$60Aug 29, 1984--
01001B1910.106
Flammable Liquids
OSHA citation code: 19100106 E02 IVD
Serious12$0$0Aug 29, 1984--
01001C1910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 G06 I
Serious12$0$0Aug 29, 1984--
01001D1910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 D
Serious12$0$0Aug 29, 1984--
01001E1910.108
Dip Tanks (Reserved)
OSHA citation code: 19100108 F04
Serious12$0$0Aug 29, 1984--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious12$120$120Aug 29, 1984--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other114$0$0Aug 29, 1984--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other13$0$0Aug 2, 1984--
020031910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Other12$0$0Aug 29, 1984--
020041910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC6
Other13$0$0Aug 2, 1984--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.108Dip Tanks (Reserved)4 citations · $0
1910.94Ventilation3 citations · $150
1910.217Mechanical Power Presses2 citations · $120

Chemical exposure sampling

Samples
42
Substances
14
Inspections
1

Other inspected employers in BROKEN ARROW, OK