Inspections
5
Jul 1975 to Sep 1982 · 4 safety, 1 health
Violations
25
across 5 inspections
Penalties on record
$1,305
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 5Other 13

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 21, 1982Planned (H) · Records Only scope, Safety#14425649$00 viol.

Inspection #14425649

Dates

Opened
Sep 21, 1982
Closing Conference Date
Sep 21, 1982
Closed
Oct 7, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
175

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
442 W Fullerton, Elmhurst, IL 60126
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jan 28, 1981Follow-Up (F) · Partial scope, Safety#14463798$00 viol.

Inspection #14463798

Dates

Opened
Jan 28, 1981
Closing Conference Date
Jan 28, 1981
Closed
Feb 12, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
174

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
442 W Fullerton Avenue, Elmhurst, IL 60126
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

May 7, 1980Planned (H) · No Inspection scope, Health#18763987$00 viol.

Inspection #18763987

Dates

Opened
May 7, 1980
Closing Conference Date
Not recorded
Closed
Jul 28, 1986

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
, Elmhurst, IL 00000
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jan 29, 1980Planned (H) · Complete scope, Safety#14467807$1,20018 viol.

Inspection #14467807

Dates

Opened
Jan 29, 1980
Closing Conference Date
Jan 29, 1980
Contested
Mar 15, 1980
Closed
Feb 12, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
174

Violations and Penalties

Total Violations
18
Violation Types
7 serious, 5 repeat, 6 other-than-serious
Initial Penalties
$9,360
Penalties on Record
$1,200
Site Address
442 W Fullerton Ave, Elmhurst, IL 60126
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 I
Serious2-$630$100Apr 25, 1980Mar 15, 1980-
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 II
Serious2-$630$100Apr 25, 1980Mar 15, 1980-
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 III
Serious8-$630$100Apr 25, 1980Mar 15, 1980-
010041910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious9-$630$100Apr 25, 1980Mar 15, 1980-
010051910.309
OSHA citation code: 19100309 A 025051
Serious3-$630$100Feb 29, 1980Mar 15, 1980-
010061910.309
OSHA citation code: 19100309 B 030004
Serious3-$630$100Apr 25, 1980Mar 15, 1980-
010071910.309
OSHA citation code: 19100309 B 034812
Serious11-$630$100Apr 25, 1980Mar 15, 1980-
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat4-$1,260$125Apr 25, 1980Mar 15, 1980-
020021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Repeat6-$1,260$125Apr 25, 1980Mar 15, 1980-
020031910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Repeat3-$1,260$125Mar 25, 1980Mar 15, 1980-

Showing the 10 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 25, 1975Planned (H) · Complete scope, Safety#214771016$1057 viol.

Inspection #214771016

Dates

Opened
Jul 25, 1975
Closing Conference Date
Jul 25, 1975
Closed
May 24, 1976

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
7
Violation Types
7 other-than-serious
Initial Penalties
$105
Penalties on Record
$105
Site Address
442 West Fullerton Avenue, Elmhurst, IL 60126
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Other5-$0$0Sep 30, 1975--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Other8-$0$0Sep 30, 1975--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other6-$35$35Sep 30, 1975--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other6-$0$0Sep 30, 1975--
010041910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IV
Other1-$0$0Sep 5, 1975--
010051910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$35$35Sep 15, 1975--
010061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Other1-$35$35Sep 15, 1975--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses8 citations · $650
1910.219Mechanical Power-Transmission Apparatus6 citations · $195
1910.3093 citations · $300

Other inspected employers in Elmhurst, IL