Skip to content
SafetyRecord logoSafetyRecord
CHRIS ERHART FOUNDRY & MACHINE
$2,936
penalties
29
viol.
8
insp.

CHRIS ERHART FOUNDRY & MACHINE

1240 MEHRING WAY, Cincinnati, OH 45203NAICS 331511 Iron Foundries

Inspections
8
Oct 1974 to Dec 2010 · 6 safety, 2 health
Violations
29
across 8 inspections
Penalties on record
$2,936
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 23

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 3, 2010Planned (H) · Complete scope, Safety#315133728$2,3364 viol.

Inspection #315133728

Dates

Opened
Dec 3, 2010
Closing Conference Date
Dec 21, 2010
Closed
Feb 24, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$3,213
Penalties on Record
$2,336
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious12$1,377$1,168Jan 27, 2011--
01005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IA
Serious12$1,836$1,168Feb 11, 2011--
01005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D03
Serious12$0$0Feb 11, 2011--
01005C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 D04 I
Serious12$0$0Feb 11, 2011--
Dec 3, 2010Planned (H) · Complete scope, Health#315133710$1003 viol.

Inspection #315133710

Dates

Opened
Dec 3, 2010
Closing Conference Date
Dec 21, 2010
Closed
Feb 23, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$1,836
Penalties on Record
$100
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC40.0703 - 0.4631mg/m³
Sample WeightQC40.045 - 0.357mg
Silica, Crystalline Quartz (Respirable Fraction)40 - 18%

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 G05 I
Other11$1,836$100Jan 7, 2011--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 E04 I
Other12$0$0Feb 18, 2011--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 K06
Other12$0$0Jan 28, 2011--
Aug 12, 1993Complaint (B) · Partial scope, Health#103030409$01 viol.

Inspection #103030409

Dates

Opened
Aug 12, 1993
Closing Conference Date
Aug 12, 1993
Closed
Sep 7, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
34
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$0
Site Address
1240 Mehring Way, Cincinnati, OH 45202
Industry
331511 Iron Foundries

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.000625mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40mg/m³
Iron Oxide Fume40 - 0.2342mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40 - 0.0176mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Silica, Crystalline Quartz (Respirable Fraction)111%
Vanadium fume (as V2O5)40mg/m³
Zinc Oxide Fume40 - 0.125mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 H
Other11$1,000$0Sep 2, 1993--
Aug 12, 1993Complaint (B) · Partial scope, Safety#103027330$01 viol.

Inspection #103027330

Dates

Opened
Aug 12, 1993
Closing Conference Date
Aug 12, 1993
Closed
Sep 8, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
34
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1240 Mehring Way, Cincinnati, OH 45202
Industry
331511 Iron Foundries

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other110$0$0Sep 19, 1993--
Jun 3, 1981Planned (H) · Complete scope, Safety#214679045$5003 viol.

Inspection #214679045

Dates

Opened
Jun 3, 1981
Closing Conference Date
Jun 3, 1981
Closed
Nov 3, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
28

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$500
Penalties on Record
$500
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious1-$250$250Jun 12, 1981--
010021910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Serious1-$250$250Jun 24, 1981--
020011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$0$0Jul 9, 1981--
Jun 1, 1981Planned (H) · Partial scope, Safety#214637514$00 viol.

Inspection #214637514

Dates

Opened
Jun 1, 1981
Closing Conference Date
Jun 3, 1981
Closed
Jun 3, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
28

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jun 4, 1975Follow-Up (F) · Complete scope, Safety#14554729$01 viol.

Inspection #14554729

Dates

Opened
Jun 4, 1975
Closing Conference Date
Jun 4, 1975
Closed
Jun 16, 1975

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
35

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 E06 II
Other1-$0$0Jun 12, 1975--
Oct 31, 1974Planned (H) · Complete scope, Safety#14553226$016 viol.

Inspection #14553226

Dates

Opened
Oct 31, 1974
Closing Conference Date
Oct 31, 1974
Closed
Feb 28, 1975

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
35

Violations and Penalties

Total Violations
16
Violation Types
16 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1240 Mehring Way, Cincinnati, OH 45203
Industry
331511 Iron Foundries

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 16 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q02
Other1-$0$0Dec 4, 1974--
010021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D03 I
Other4-$0$0Dec 4, 1974--
010031910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other1-$0$0Dec 4, 1974--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other1-$0$0Dec 26, 1974--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Other1-$0$0Feb 12, 1975--
010061910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 F02
Other1-$0$0Dec 4, 1974--

Showing the 6 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.157Portable Fire Extinguishers4 citations · $0
1910.215Abrasive Wheel Machinery3 citations · $0
1910.106Flammable Liquids3 citations · $0

Chemical exposure sampling

Samples
61
Substances
15
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer3.6
Industry average3.1
Penalties per inspection
This employer$367
Industry average$2,971

Primary Metal Manufacturing, 9,077 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: iron foundries reported 5.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source