Skip to content
SafetyRecord logoSafetyRecord
REICHERT STAMPING CO.
$10,970
penalties
62
viol.
19
insp.

REICHERT STAMPING CO.

8200 WEST CENTRAL AVENUE, TOLEDO, OH 43696NAICS 336340 Motor Vehicle Brake System Manufacturing

Inspections
19
Mar 1977 to Sep 2002 · 13 safety, 6 health
Violations
62
across 19 inspections
Penalties on record
$10,970
latest amounts in DOL records
By classification
Serious 23Willful 0Repeat 1Other 38

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 1, 1985Complaint (B) · Partial scope, Health#2421220$00 viol.

Inspection #2421220

Dates

Opened
Nov 1, 1985
Closing Conference Date
Jan 2, 1986
Closed
Jan 2, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
160
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8200 West Central Ave, Toledo, OH 43696
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
2-Butoxyethanol20
Jul 2, 1985Planned (H) · Records Only scope, Safety#2420743$00 viol.

Inspection #2420743

Dates

Opened
Jul 2, 1985
Closing Conference Date
Jul 2, 1985
Closed
Jul 2, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
150

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8200 West Central Ave, Toledo, OH 43696
Industry
336340 Motor Vehicle Brake System Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 5, 1984Complaint (B) · Partial scope, Health#1565621$00 viol.

Inspection #1565621

Dates

Opened
Dec 5, 1984
Closing Conference Date
Jan 15, 1985
Closed
Jan 17, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
177
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8200 West Central Ave, Toledo, OH 43617
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Apr 16, 1984Accident (A) · Partial scope, Health#1565522$00 viol.

Inspection #1565522

Dates

Opened
Apr 16, 1984
Closing Conference Date
Apr 16, 1984
Closed
Apr 27, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
150
Related Activity
1 accident

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8200 West Central Ave, Toledo, OH 43617
Industry
336340 Motor Vehicle Brake System Manufacturing

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Jul 7, 1982Complaint (B) · Partial scope, Safety#16057465$64020 viol.

Inspection #16057465

Dates

Opened
Jul 7, 1982
Closing Conference Date
Jul 9, 1982
Closed
Oct 25, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
144
Related Activity
1 complaint

Violations and Penalties

Total Violations
20
Violation Types
4 serious, 16 other-than-serious
Initial Penalties
$1,280
Penalties on Record
$640
Site Address
8200 West Central Ave, Toledo, OH 43617
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 20 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious2-$240$120Aug 28, 1982--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A04
Serious4-$240$120Sep 8, 1982--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious3-$480$240Sep 15, 1982--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 IIIG
Serious2-$320$160Aug 4, 1982--
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other1-$0$0Aug 28, 1982--

Showing the 5 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 17, 1980Complaint (B) · Partial scope, Safety#15991540$1501 viol.

Inspection #15991540

Dates

Opened
Dec 17, 1980
Closing Conference Date
Dec 17, 1980
Closed
Jan 19, 1981

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
113
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$150
Penalties on Record
$150
Site Address
8200 West Central, Toledo, OH 43617
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 D09 IV
Serious12-$150$150Jan 23, 1981--
Jul 11, 1980Complaint (B) · Partial scope, Safety#16004558$4204 viol.

Inspection #16004558

Dates

Opened
Jul 11, 1980
Closing Conference Date
Jul 17, 1980
Closed
Aug 27, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
88
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$420
Penalties on Record
$420
Site Address
8200 West Central Avenue, Toledo, OH 43617
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B07 IV
Serious1-$140$140Sep 12, 1980--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Repeat1-$280$280Sep 12, 1980--
030011910.217
Mechanical Power Presses
OSHA citation code: 19100217 B07 III
Other1-$0$0Aug 5, 1980--
030021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 I
Other3-$0$0Aug 12, 1980--
Oct 6, 1978Complaint (B) · Partial scope, Safety#16084485$01 viol.

Inspection #16084485

Dates

Opened
Oct 6, 1978
Closing Conference Date
Oct 6, 1978
Closed
Nov 17, 1978

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
139
Related Activity
1 complaint

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2242 Smead Ave, Toledo, OH 43606
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Other1-$0$0Nov 16, 1978--
Mar 10, 1977Complaint (B) · Complete scope, Safety#16083347$09 viol.

Inspection #16083347

Dates

Opened
Mar 10, 1977
Closing Conference Date
Mar 10, 1977
Closed
Sep 9, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
146

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2242 Smead, Toledo, OH 43606
Industry
336340 Motor Vehicle Brake System Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other1-$0$0Apr 8, 1977--
010021910.29
Fall Protection Systems and Criteria
OSHA citation code: 19100029 A03 VII
Other1-$0$0Mar 31, 1977--
010031910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 F02 I
Other1-$0$0Apr 28, 1977--
010041910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 A02
Other1-$0$0Apr 1, 1977--
010051910.178
Powered Industrial Trucks
OSHA citation code: 19100178 K01
Other1-$0$0Apr 28, 1977--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 11 to 19 of 19, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses13 citations · $3,020
1910.212General Requirements for All Machines (Machine Guarding)9 citations · $2,430
1910.219Mechanical Power-Transmission Apparatus5 citations · $900

Chemical exposure sampling

Samples
2
Substances
1
Inspections
1

Industry comparison

Violations per inspection
This employer3.3
Industry average2.9
Penalties per inspection
This employer$577
Industry average$2,709

Transportation Equipment Manufacturing, 16,540 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in TOLEDO, OH

All employers in TOLEDO →