SHEBOYGAN PAINT COMPANY
1439 N 25TH STREET, SHEBOYGAN, WI 53081
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 29, 1994#103523809Mar 29, 1994Planned (H) · Complete scope, Health#103523809$00 viol.0 violations$0 in penalties
Inspection #103523809
Dates
- Opened
- Mar 29, 1994
- Closing Conference Date
- Mar 30, 1994
- Closed
- May 19, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 80
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1439 N. 25th, Sheboygan, WI 53081
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling23 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 2-Butoxyethanol | 7 | 0.3016 - 0.8276 | ppm |
| 2-Propoxyethanol | 7 | 0.1369 - 0.5737 | ppm |
| Antimony and Compounds (as Sb) | 2 | 0 | mg/m³ |
| Benzene | 16 | 0 | ppm |
| Beryllium and Beryllium Compounds (as Be) | 2 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 2 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 2 | 0 | mg/m³ |
| Copper Fume (as Cu) | 2 | 0 | mg/m³ |
| Diisobutyl Ketone | 5 | 0.2383 - 6.3 | ppm |
| Ethyl Benzene | 11 | 0.8841 - 6.0972 | ppm |
| Hexone | 5 | 1.5698 - 19.3 | ppm |
| Iron Oxide Fume | 2 | 0 - 0.0233 | mg/m³ |
| Isopropyl Alcohol | 11 | 0.5842 - 7.0225 | ppm |
| Lead, Inorganic (as Pb) | 2 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 2 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 2 | 0 | mg/m³ |
| n-Butyl Alcohol | 13 | 0.9634 - 11.6 | ppm |
| Nickel, Metal and Insoluble compounds (as Ni) | 2 | 0 | mg/m³ |
| Toluene | 16 | 6.9889 - 112.1 | ppm |
| Trimethylbenzene (mixed isomers) | 11 | 0.1993 - 0.9456 | ppm |
| Vanadium fume (as V2O5) | 2 | 0 | mg/m³ |
| Xylene | 16 | 3.8908 - 96.2 | ppm |
| Zinc Oxide Fume | 2 | 0 - 0.0033 | mg/m³ |
Mar 29, 1994#103522108Mar 29, 1994Planned (H) · Complete scope, Safety#103522108$1,6007 viol.7 violations$1,600 in penalties
Inspection #103522108
Dates
- Opened
- Mar 29, 1994
- Closing Conference Date
- Mar 29, 1994
- Closed
- May 26, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 80
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 4 serious, 3 other-than-serious
- Initial Penalties
- $2,700
- Penalties on Record
- $1,600
- Site Address
- 1439 N. 25th, Sheboygan, WI 53081
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 II | Serious | 1 | 3 | $900 | $550 | May 25, 1994 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 3 | $900 | $525 | May 25, 1994 | - | - |
| 01003A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 3 | $900 | $525 | May 25, 1994 | - | - |
| 01003B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Serious | 1 | 3 | $0 | $0 | May 25, 1994 | - | - |
| 02001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 F06 | Other | 1 | 3 | $0 | $0 | Apr 25, 1994 | - | - |
| 02002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q01 | Other | 1 | 5 | $0 | $0 | May 25, 1994 | - | - |
| 02003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 3 | $0 | $0 | Apr 25, 1994 | - | - |
Apr 15, 1986#100113968Apr 15, 1986Planned (H) · Complete scope, Health#100113968$31011 viol.11 violations$310 in penalties
Inspection #100113968
Dates
- Opened
- Apr 15, 1986
- Closing Conference Date
- May 21, 1986
- Closed
- Aug 10, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 75
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 7 serious, 4 other-than-serious
- Initial Penalties
- $600
- Penalties on Record
- $310
- Site Address
- 1439 North 25th Street, Sheboygan, WI 53081
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling23 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 2-Butanone | 25 | 0 - 31.3 | |
| Antimony and Compounds (as Sb) | 18 | 0 - 0.0181 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 17 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 18 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 18 | 0 - 0.0033 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 18 | 0 | mg/m³ |
| Copper Fume (as Cu) | 18 | 0 - 0.0051 | mg/m³ |
| Hexamethylene Diisocyanate | 4 | 0 | mg/m³ |
| Hexone | 21 | 0.4 - 127 | ppm |
| Iron Oxide Fume | 18 | 0 - 0.047 | mg/m³ |
| Lead, Inorganic (as Pb) | 18 | 0 - 0.0198 | mg/m³ |
| Manganese Fume (as Mn) | 18 | 0 - 0.0265 | mg/m³ |
| Methylene bisphenyl isocyanate | 4 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 18 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 18 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 17 | 0 | mg/m³ |
| Petroleum Distillates (Naphtha) (Rubber Solvent) | 21 | 4 - 1210 | mg/m³ |
| Toluene | 21 | 1.7 - 256 | ppm |
| Toluene-2,4-Diisocyanate (TDI) | 4 | 0 | mg/m³ |
| Toluene-2,6-Diisocyanate | 4 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 18 | 0 | mg/m³ |
| Xylene | 21 | 0.9 - 138 | ppm |
| Zinc Oxide Fume | 18 | 0 - 0.0457 | mg/m³ |
Violations
Violation list (11 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F01 II | Other | 3 | 10 | $0 | $0 | Jul 24, 1987 | - | - |
| 01002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G02 IC | Other | 5 | 10 | $0 | $0 | Oct 27, 1986 | - | - |
| 01003 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G02 IV | Other | 3 | 10 | $0 | $0 | Jan 26, 1987 | - | - |
| 01004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G02 VI | Other | 3 | 10 | $0 | $0 | Oct 27, 1986 | - | - |
| 02001A | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Serious | 1 | 1 | $200 | $100 | Apr 24, 1987 | - | - |
| 02001B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | Apr 24, 1987 | - | - |
| 02002A | 1910.1000 Air Contaminants OSHA citation code: 19101000 B01 | Serious | 1 | 1 | $200 | $110 | Apr 24, 1987 | - | - |
| 02002B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | Apr 24, 1987 | - | - |
| 02003A | 1910.1000 Air Contaminants OSHA citation code: 19101000 D02 I | Serious | 1 | 1 | $200 | $100 | Apr 24, 1987 | - | - |
| 02003B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Serious | 1 | 1 | $0 | $0 | Apr 24, 1987 | - | - |
| 02003C | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | 1 | $0 | $0 | Apr 24, 1987 | - | - |
Apr 25, 1984#1695550Apr 25, 1984Planned (H) · Complete scope, Safety#1695550$60013 viol.13 violations$600 in penalties
Inspection #1695550
Dates
- Opened
- Apr 25, 1984
- Closing Conference Date
- Apr 25, 1984
- Closed
- Oct 24, 1984
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 76
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 3 serious, 10 other-than-serious
- Initial Penalties
- $720
- Penalties on Record
- $600
- Site Address
- 1439 N 25th Street, Sheboygan, WI 53081
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (12 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 I | Serious | 2 | 4 | $300 | $300 | May 21, 1984 | - | - |
| 01001B | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 II | Serious | 2 | 4 | $0 | $0 | May 21, 1984 | - | - |
| 01002 | 1910.307 Electrical - Hazardous (Classified) Locations OSHA citation code: 19100307 B | Serious | 10 | 18 | $420 | $300 | Nov 5, 1984 | - | - |
| 02001A | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Other | 10 | 4 | $0 | $0 | Aug 5, 1984 | - | - |
| 02001B | 1910.106 Flammable Liquids OSHA citation code: 19100106 D02 I | Other | 10 | 4 | $0 | $0 | Aug 5, 1984 | - | - |
| 02002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Other | 2 | 4 | $0 | $0 | Aug 5, 1984 | - | - |
| 02004 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Other | 1 | 2 | $0 | $0 | Sep 5, 1984 | - | - |
| 02005 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Other | 2 | 2 | $0 | $0 | May 14, 1984 | - | - |
| 02006 | 1910.159 Automatic Sprinkler Systems OSHA citation code: 19100159 C10 | Other | 1 | 1 | $0 | $0 | Jun 5, 1984 | - | - |
| 02007 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 C02 V | Other | 2 | 4 | $0 | $0 | Sep 5, 1984 | - | - |
| 02008 | 1910.1025 Lead OSHA citation code: 19101025 D02 | Other | 2 | 4 | $0 | $0 | Aug 6, 1984 | - | - |
| 02009A | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Other | 3 | 6 | $0 | $0 | Aug 6, 1984 | - | - |
Showing the 12 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
4 inspections, 1984 to 1994. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.