Skip to content
SafetyRecord logoSafetyRecord
ACE AUTO BODY
$0
penalties
11
viol.
2
insp.

ACE AUTO BODY

HIGHWAY 83, SALEM, WI 53168

Inspections
2
May 1984 to Jun 1984 · 1 safety, 1 health
Violations
11
across 2 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 2Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 8, 1984Complaint (B) · Partial scope, Safety#1706647$011 viol.

Inspection #1706647

Dates

Opened
Jun 8, 1984
Closing Conference Date
Jun 8, 1984
Closed
Oct 22, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 complaint

Violations and Penalties

Total Violations
11
Violation Types
2 serious, 9 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Highway 83, Salem, WI 53168
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious13$0$0Jul 24, 1984--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious23$0$0Jul 24, 1984--
020011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other13$0$0Aug 23, 1984--
020021910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 IV
Other13$0$0Aug 23, 1984--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G07
Other13$0$0Aug 23, 1984--
020041910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 A
Other13$0$0Aug 23, 1984--
020051910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other23$0$0Aug 23, 1984--
020061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC1
Other13$0$0Aug 23, 1984--
020071910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC8
Other13$0$0Aug 23, 1984--
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Other13$0$0Aug 23, 1984--
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIA
Other13$0$0Aug 23, 1984--
May 30, 1984Complaint (B) · Partial scope, Health#1707132$00 viol.

Inspection #1707132

Dates

Opened
May 30, 1984
Closing Conference Date
Jul 16, 1984
Closed
Jul 16, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Hyw 83, Salem, WI 53168
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling14 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)10mg/m³
Beryllium and Beryllium Compounds (as Be)10mg/m³
Cadmium Fume (as Cd)10mg/m³
Chromium, Soluble Chromic, Chromous Salts (as Cr)10mg/m³
Cobalt, Metal, Dust and Fume (as Co)10mg/m³
Copper Fume (as Cu)10mg/m³
Iron Oxide Fume10.1954mg/m³
Lead, Inorganic (as Pb)10mg/m³
Manganese Fume (as Mn)10mg/m³
Molybdenum (as Mo), Soluble Compounds10mg/m³
Nickel, Metal and Insoluble compounds (as Ni)10mg/m³
Particulates not otherwise regulated (Respirable Fraction)10mg/m³
Vanadium fume (as V2O5)10mg/m³
Zinc Oxide Fume10mg/m³
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0
1910.304Electrical - Wiring Design and Protection3 citations · $0
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $0

Chemical exposure sampling

Samples
14
Substances
14
Inspections
1

Other inspected employers in SALEM, WI

All employers in SALEM →