COLLINS PLATING CORP.
5726 BYRD DR., LOVELAND, CO 80537
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 28, 1988#100608587Mar 28, 1988Referral (C) · Complete scope, Safety#100608587$5207 viol.7 violations$520 in penalties
Inspection #100608587
Dates
- Opened
- Mar 28, 1988
- Closing Conference Date
- Mar 29, 1988
- Closed
- Jul 11, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 27
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 4 serious, 3 other-than-serious
- Initial Penalties
- $520
- Penalties on Record
- $520
- Site Address
- 5726 Byrd Dr., Loveland, CO 80537
- Industry
- Not classified in OSHA's inspection record.
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (7 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Serious | 1 | 1 | $120 | $120 | Jun 1, 1988 | - | - |
| 01002 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 1 | 1 | $160 | $160 | Jun 1, 1988 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 2 | 1 | $120 | $120 | Jun 1, 1988 | - | - |
| 01004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Serious | 1 | 1 | $120 | $120 | Jun 1, 1988 | - | - |
| 02001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 VII | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
| 02002 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
Feb 8, 1988#1871698Feb 8, 1988Complaint (B) · Partial scope, Health#1871698$18010 viol.10 violations$180 in penalties
Inspection #1871698
Dates
- Opened
- Feb 8, 1988
- Closing Conference Date
- Mar 25, 1988
- Closed
- Jul 11, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 28
- Related Activity
- 2 complaints
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 2 serious, 8 other-than-serious
- Initial Penalties
- $180
- Penalties on Record
- $180
- Site Address
- 5726 Byrd Dr., Loveland, CO 80537
- Industry
- Not classified in OSHA's inspection record.
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling6 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Chromic Acid and Chromates (as CrO3) | 2 | 0 | mg/m³ |
| Methylene Chloride | 84P / 4A | 0 - 95.6 | ppm |
| Nickel, Metal and Insoluble compounds (as Ni) | 2 | 0.061 - 0.18 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 2 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 64P / 2A | 0 | mg/m³ |
| Sulfuric Acid | 42P / 2A | 0.033 - 0.06 | mg/m³ |
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 II | Serious | 1 | 1 | $90 | $90 | Jun 1, 1988 | - | - |
| 01002 | 1910.94 Ventilation OSHA citation code: 19100094 D09 V | Serious | 3 | 2 | $90 | $90 | Jun 1, 1988 | - | - |
| 02001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C01 | Other | 5 | 16 | $0 | $0 | Jun 1, 1988 | - | - |
| 02002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Other | 1 | 7 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003A | 1910.134 Respiratory Protection OSHA citation code: 19100134 B01 | Other | 1 | 6 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003B | 1910.134 Respiratory Protection OSHA citation code: 19100134 B02 | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003C | 1910.134 Respiratory Protection OSHA citation code: 19100134 B03 | Other | 1 | 6 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003D | 1910.134 Respiratory Protection OSHA citation code: 19100134 B06 | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
| 02003E | 1910.134 Respiratory Protection OSHA citation code: 19100134 E05 I | Other | 1 | 1 | $0 | $0 | Jun 1, 1988 | - | - |
| 02004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 II | Other | 4 | 16 | $0 | $0 | Jun 1, 1988 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1988 to 1988. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.