BRENNER TANK LLC
450 ARLINGTON AVENUE, Fond du Lac, WI 54935 · NAICS 332420 Metal Tank (Heavy Gauge) Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
May 16, 1989#103078507May 16, 1989Planned (H) · Complete scope, Safety#103078507$8158 viol.8 violations$815 in penalties
Inspection #103078507
Dates
- Opened
- May 16, 1989
- Closing Conference Date
- May 16, 1989
- Closed
- Nov 24, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 205
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 7 serious, 1 other-than-serious
- Initial Penalties
- $1,540
- Penalties on Record
- $815
- Site Address
- 450 Arlington, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $70 | $70 | Jun 14, 1989 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $420 | $210 | Oct 10, 1989 | - | - |
| 01003 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 1 | $210 | $105 | Jun 9, 1989 | - | - |
| 01004 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 1 | $140 | $70 | Jun 9, 1989 | - | - |
| 01005A | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C02 IA | Serious | 1 | 2 | $420 | $220 | Jun 9, 1989 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 15, 1988#102539707Aug 15, 1988Follow-Up (F) · Partial scope, Health#102539707$1,0505 viol.5 violations$1,050 in penalties
Inspection #102539707
Dates
- Opened
- Aug 15, 1988
- Closing Conference Date
- Oct 6, 1988
- Closed
- Sep 13, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 218
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 2 serious, 3 repeat
- Initial Penalties
- $1,430
- Penalties on Record
- $1,050
- Site Address
- 450 Arlington, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling17 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 7 | 0 - 0.0117 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 5 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 7 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 7 | 0 - 2.1041 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 7 | 0 | mg/m³ |
| Copper Fume (as Cu) | 7 | 0 - 0.0372 | mg/m³ |
| Hexamethylene Diisocyanate | 1 | 0.006 | mg/m³ |
| Iron Oxide Fume | 7 | 0 - 12.7002 | mg/m³ |
| Lead, Inorganic (as Pb) | 7 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 7 | 0 - 0.2236 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 7 | 0 - 0.076 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 7 | 0 - 1.0988 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 5 | 14.9695 | mg/m³ |
| Qualitative Mass-Spec AnalysisQC | 1 | 0 | |
| Stoddard Solvent | 2 | 0 - 65.821 | |
| Trimethylbenzene (mixed isomers) | 2 | 0 - 0.6177 | |
| Vanadium fume (as V2O5) | 7 | 0 - 0.0201 | mg/m³ |
| Zinc Oxide Fume | 7 | 0 - 0.3914 | mg/m³ |
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E04 IV | Serious | 1 | 1 | $640 | $300 | Jan 31, 1989 | - | - |
| 01001B | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E04 IV | Serious | 1 | 1 | $0 | $0 | Jan 31, 1989 | - | - |
| 02001A | 1910.1000 Air Contaminants OSHA citation code: 19101000 A02 | Repeat | 2 | 2 | $700 | $700 | Sep 13, 1989 | - | - |
| 02001B | 1910.1000 Air Contaminants OSHA citation code: 19101000 E | Repeat | 2 | 2 | $0 | $0 | Sep 13, 1989 | - | - |
| 02002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 II | Repeat | 1 | 1 | $90 | $50 | Nov 28, 1988 | - | - |
Jun 24, 1987#101296200Jun 24, 1987Follow-Up (F) · Partial scope, Health#101296200$5,35020 viol.20 violations$5,350 in penalties
Inspection #101296200
Dates
- Opened
- Jun 24, 1987
- Closing Conference Date
- Sep 11, 1987
- Closed
- Feb 6, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 160
Violations and Penalties
- Total Violations
- 20
- Violation Types
- 7 serious, 5 willful, 8 repeat
- Initial Penalties
- $6,900
- Penalties on Record
- $5,350
- Site Address
- 450 Arlington Ave., Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling17 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 5 | 0 - 0.0738 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 4 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 5 | 0 - 0.003 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 5 | 0 - 11.6681 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 5 | 0 | mg/m³ |
| Copper Fume (as Cu) | 5 | 0 - 0.0877 | mg/m³ |
| Iron Oxide Fume | 5 | 0 - 61.1921 | mg/m³ |
| Lead, Inorganic (as Pb) | 5 | 0 - 1.039 | mg/m³ |
| Manganese Fume (as Mn) | 5 | 0 - 1.0414 | mg/m³ |
| Methyl Chloroform | 6 | 51 - 1394 | ppm |
| Methylene Chloride | 6 | 41 - 1889 | ppm |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 5 | 0 - 1.3451 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 5 | 0 - 7.6712 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 5 | 0 | mg/m³ |
| Petroleum Distillates (Naphtha) (Rubber Solvent) | 6 | 8 - 3983 | mg/m³ |
| Qualitative Mass-Spec AnalysisQC | 1 | 0 | |
| Vanadium fume (as V2O5) | 5 | 0 - 0.0812 | mg/m³ |
| Zinc Oxide Fume | 5 | 0 - 0.0674 | mg/m³ |
Violations
Violation list (5 of 20 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01003A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 2 | 2 | $400 | $100 | Nov 9, 1987 | - | - |
| 01003B | 1910.1025 Lead OSHA citation code: 19101025 F03 I | Serious | 1 | 1 | $0 | $0 | Dec 2, 1987 | - | - |
| 01004 | 1910.1025 Lead OSHA citation code: 19101025 D02 | Serious | 1 | 2 | $400 | $100 | Feb 4, 1988 | - | - |
| 01005 | 1910.1025 Lead OSHA citation code: 19101025 I03 II | Serious | 1 | 2 | $400 | $100 | Nov 9, 1987 | - | - |
| 01006A | 1910.1025 Lead OSHA citation code: 19101025 L01 I | Serious | 1 | 2 | $400 | $100 | Jan 9, 1988 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 22, 1986#100107838Sep 22, 1986Complaint (B) · Partial scope, Safety#100107838$4005 viol.5 violations$400 in penalties
Inspection #100107838
Dates
- Opened
- Sep 22, 1986
- Closing Conference Date
- Oct 3, 1986
- Closed
- Feb 5, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 150
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 1 serious, 4 other-than-serious
- Initial Penalties
- $400
- Penalties on Record
- $400
- Site Address
- 450 Arlington Ave., Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 3 | $400 | $400 | Jan 21, 1987 | - | - |
| 02001 | 1910.184 Slings OSHA citation code: 19100184 E01 | Other | 1 | 4 | $0 | $0 | Jan 21, 1987 | - | - |
| 02002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 I | Other | 1 | 180 | $0 | $0 | Dec 22, 1986 | - | - |
| 02003 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F04 II | Other | 1 | 180 | $0 | $0 | Jan 21, 1987 | - | - |
| 02004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Other | 1 | 180 | $0 | $0 | Nov 21, 1986 | - | - |
Jul 16, 1985#1953603Jul 16, 1985Complaint (B) · Complete scope, Health#1953603$3,65020 viol.20 violations$3,650 in penalties
Inspection #1953603
Dates
- Opened
- Jul 16, 1985
- Closing Conference Date
- Nov 6, 1985
- Closed
- Nov 27, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 215
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 20
- Violation Types
- 12 serious, 1 willful, 5 repeat, 2 other-than-serious
- Initial Penalties
- $12,500
- Penalties on Record
- $3,650
- Site Address
- 450 Arlington Ave, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling20 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 10 | 0 - 0.1409 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 10 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 10 | 0 - 0.0022 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 10 | 0.0061 - 5.787 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 10 | 0 - 0.096 | mg/m³ |
| Copper Fume (as Cu) | 10 | 0 - 0.14 | mg/m³ |
| Iron Oxide Fume | 10 | 0.0558 - 32 | mg/m³ |
| Lead, Inorganic (as Pb) | 10 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 10 | 0 - 0.49 | mg/m³ |
| Methylene Chloride | 12 | 0 - 291.3 | |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 10 | 0 - 0.1267 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 10 | 0 - 5.0637 | mg/m³ |
| Nitric Acid | 2 | 0.16 - 1.1 | ppm |
| Particulates not otherwise regulated (Respirable Fraction) | 12 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 2 | 0 | mg/m³ |
| Stoddard Solvent | 12 | 0 - 2151.5 | |
| Tetrachloroethylene (Perchloroethylene) | 12 | 0 - 26.9 | |
| Toluene | 12 | 0 - 507.2 | |
| Vanadium fume (as V2O5) | 10 | 0 - 0.0579 | mg/m³ |
| Zinc Oxide Fume | 10 | 0 - 0.6551 | mg/m³ |
Violations
Violation list (5 of 20 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 A06 I | Serious | 1 | 2 | $600 | $200 | Feb 24, 1986 | - | - |
| 01002A | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | 2 | $300 | $100 | Nov 29, 1985 | - | - |
| 01002B | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 2 | $0 | $0 | Dec 5, 1985 | - | - |
| 01002C | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $0 | $0 | Feb 24, 1986 | - | - |
| 01003A | 1910.134 Respiratory Protection OSHA citation code: 19100134 B02 | Serious | 1 | 1 | $400 | $200 | Nov 22, 1985 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 14, 1985#2493773Mar 14, 1985Planned (H) · Complete scope, Safety#2493773$40015 viol.15 violations$400 in penalties
Inspection #2493773
Dates
- Opened
- Mar 14, 1985
- Closing Conference Date
- Mar 15, 1985
- Closed
- Feb 3, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 213
Violations and Penalties
- Total Violations
- 15
- Violation Types
- 1 serious, 3 repeat, 11 other-than-serious
- Initial Penalties
- $1,260
- Penalties on Record
- $400
- Site Address
- 450 Arlington Ave, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 15 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 2 | $360 | $50 | Mar 18, 1986 | - | - |
| 02001A | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E04 IV | Repeat | 1 | 1 | $900 | $350 | May 12, 1985 | - | - |
| 02001B | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E04 IV | Repeat | 1 | 1 | $0 | $0 | May 12, 1985 | - | - |
| 02001C | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 F02 IC | Repeat | 1 | 1 | $0 | $0 | May 12, 1985 | - | - |
| 03001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | 1 | $0 | $0 | Apr 5, 1985 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 11, 1982#14405765May 11, 1982Planned (H) · Complete scope, Health#14405765$51011 viol.11 violations$510 in penalties
Inspection #14405765
Dates
- Opened
- May 11, 1982
- Closing Conference Date
- Jun 25, 1982
- Closed
- Jul 6, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 182
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 9 serious, 2 other-than-serious
- Initial Penalties
- $1,890
- Penalties on Record
- $510
- Site Address
- 450 Arlington Ave, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 5A0001 General Duty Clause, Section 5(a)(1) | Serious | 1 | - | $560 | $100 | Nov 1, 1982 | - | - |
| 01002A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B01 | Serious | 3 | - | $560 | $100 | Mar 21, 1983 | - | - |
| 01002B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 N01 | Serious | 30 | - | $0 | $0 | Aug 30, 1982 | - | - |
| 01004 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | - | $350 | $50 | Sep 20, 1982 | - | - |
| 01005B | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 E04 IV | Serious | 1 | - | $0 | $50 | Aug 19, 1982 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 23, 1981#14389365Sep 23, 1981Planned (H) · Complete scope, Safety#14389365$1,18014 viol.14 violations$1,180 in penalties
Inspection #14389365
Dates
- Opened
- Sep 23, 1981
- Closing Conference Date
- Oct 15, 1981
- Closed
- Jun 7, 1982
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 242
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 7 serious, 7 other-than-serious
- Initial Penalties
- $1,350
- Penalties on Record
- $1,180
- Site Address
- 450 Arlington Ave, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 B08 | Serious | 1 | - | $630 | $630 | Dec 24, 1981 | - | - |
| 01001B | 1910.134 Respiratory Protection OSHA citation code: 19100134 E02 | Serious | 1 | - | $0 | $0 | Dec 24, 1981 | - | - |
| 01001C | 1910.134 Respiratory Protection OSHA citation code: 19100134 E03 | Serious | 1 | - | $0 | $0 | Dec 24, 1981 | - | - |
| 01002A | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | - | $450 | $450 | Nov 2, 1981 | - | - |
| 01002B | 1910.217 Mechanical Power Presses OSHA citation code: 19100217 C01 I | Serious | 1 | - | $0 | $0 | Dec 18, 1981 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Feb 13, 1978#14387336Feb 13, 1978Planned (H) · Partial scope, Safety#14387336$05 viol.5 violations$0 in penalties
Inspection #14387336
Dates
- Opened
- Feb 13, 1978
- Closing Conference Date
- Feb 13, 1978
- Closed
- Feb 22, 1978
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 180
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 450 Arlington Avenue, Fond Du Lac, WI 54935
- Industry
- 332420 Metal Tank (Heavy Gauge) Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.36 Design and Construction Requirements for Exit Routes OSHA citation code: 19100036 D01 | Other | 1 | - | $0 | $0 | Feb 18, 1978 | - | - |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IIB2 | Other | 1 | - | $0 | $0 | Feb 24, 1978 | - | - |
| 01003 | 1910.176 Handling Materials - General OSHA citation code: 19100176 C | Other | 2 | - | $0 | $0 | Mar 6, 1978 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 2 | - | $0 | $0 | Mar 6, 1978 | - | - |
| 01005 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Other | 1 | - | $0 | $0 | Feb 24, 1978 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
19 inspections, 1978 to 2014. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.