CLEVELAND ALUMINUM CASTING CO.
877 ADDISON ROAD, CLEVELAND, OH 44103
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Aug 5, 1988#103023420Aug 5, 1988Follow-Up (F) · Partial scope, Health#103023420$2,4858 viol.8 violations$2,485 in penalties
Inspection #103023420
Dates
- Opened
- Aug 5, 1988
- Closing Conference Date
- Oct 26, 1988
- Contested
- Dec 2, 1988
- Final Order
- Apr 24, 1989
- Closed
- Aug 24, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 28
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 6 repeat, 2 other-than-serious
- Initial Penalties
- $7,840
- Penalties on Record
- $2,485
- Site Address
- 877 Addison Rd., Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 20 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 18 | 0 | mg/m³ |
| Cadmium Fume (as Cd) | 20 | 0 - 0.0534 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 20 | 0 - 0.0033 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 20 | 0 | mg/m³ |
| Copper Fume (as Cu) | 20 | 0 - 4.6772 | mg/m³ |
| Iron Oxide Fume | 20 | 0 - 0.1455 | mg/m³ |
| Lead, Inorganic (as Pb) | 20 | 0 - 0.4289 | mg/m³ |
| Manganese Fume (as Mn) | 20 | 0 - 0.0289 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 20 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 20 | 0 - 0.0534 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 18 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 20 | 0 - 0.0044 | mg/m³ |
| Zinc Oxide Fume | 20 | 0 - 1.6326 | mg/m³ |
Violations
Violation list (5 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Repeat | 1 | 1 | $1,600 | $405 | Nov 21, 1988 | Dec 2, 1988 | Apr 24, 1989 |
| 01002 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Repeat | 1 | 1 | $640 | $210 | Nov 21, 1988 | Dec 2, 1988 | Apr 24, 1989 |
| 01003A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Repeat | 1 | 2 | $4,000 | $1,340 | Feb 21, 1989 | Dec 2, 1988 | Apr 24, 1989 |
| 01003B | 1910.1025 Lead OSHA citation code: 19101025 E01 I | Repeat | 1 | 1 | $0 | $0 | Feb 21, 1989 | Dec 2, 1988 | Apr 24, 1989 |
| 01003C | 1910.1025 Lead OSHA citation code: 19101025 E05 I | Repeat | 1 | 1 | $0 | $0 | Dec 21, 1988 | Dec 2, 1988 | Apr 24, 1989 |
Showing the 5 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 12, 1988#101311777Jan 12, 1988Planned (H) · Records Only scope, Safety#101311777$00 viol.0 violations$0 in penalties
Inspection #101311777
Dates
- Opened
- Jan 12, 1988
- Closing Conference Date
- Jan 12, 1988
- Closed
- Jan 12, 1988
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 877 Addison Rd., Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jun 30, 1987#101287563Jun 30, 1987Monitoring (D) · Partial scope, Health#101287563$00 viol.0 violations$0 in penalties
Inspection #101287563
Dates
- Opened
- Jun 30, 1987
- Closing Conference Date
- Jun 30, 1987
- Closed
- Jul 14, 1987
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 30
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 877 Addison Rd., Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Dec 10, 1986#103216123Dec 10, 1986Follow-Up (F) · Partial scope, Health#103216123$5,00022 viol.22 violations$5,000 in penalties
Inspection #103216123
Dates
- Opened
- Dec 10, 1986
- Closing Conference Date
- May 6, 1987
- Contested
- May 26, 1987
- Final Order
- Sep 10, 1987
- Closed
- Feb 14, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 31
Violations and Penalties
- Total Violations
- 22
- Violation Types
- 4 serious, 15 willful, 3 other-than-serious
- Initial Penalties
- $73,000
- Penalties on Record
- $5,000
- Site Address
- 877 Addison Rd., Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Chemical Exposure Sampling2 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Lead, Inorganic (as Pb) | 2422P / 2A | 0 - 0.56 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 2422P / 2A | 0 | mg/m³ |
Violations
Violation list (5 of 22 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 9 | 9 | $900 | $100 | May 22, 1987 | May 26, 1987 | Sep 10, 1987 |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $300 | $100 | May 15, 1987 | May 26, 1987 | Sep 10, 1987 |
| 01003A | 1910.1025 Lead OSHA citation code: 19101025 C01 | Serious | 7 | 9 | $800 | $100 | May 22, 1987 | May 26, 1987 | Sep 10, 1987 |
| 01003B | 1910.1025 Lead OSHA citation code: 19101025 G02 VIII | Serious | 1 | 5 | $0 | $0 | May 15, 1987 | May 26, 1987 | Sep 10, 1987 |
| 02001A | 1910.1025 Lead OSHA citation code: 19101025 D06 II | Willful | 2 | 9 | $10,000 | $850 | May 22, 1987 | May 26, 1987 | Sep 10, 1987 |
Showing the 5 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Sep 29, 1983#214922528Sep 29, 1983Follow-Up (F) · Partial scope, Health#214922528$15,00032 viol.32 violations$15,000 in penalties
Inspection #214922528
Dates
- Opened
- Sep 29, 1983
- Closing Conference Date
- Dec 9, 1983
- Contested
- Mar 2, 1984
- Final Order
- Sep 18, 1986
- Closed
- Jan 5, 1987
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 26
Violations and Penalties
- Total Violations
- 32
- Violation Types
- 27 willful, 3 repeat, 2 other-than-serious
- Initial Penalties
- $41,000
- Penalties on Record
- $15,000
- Site Address
- 877 Addison Road, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (5 of 32 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I02 I | Willful | 3 | - | $8,000 | $2,000 | Feb 24, 1984 | Mar 2, 1984 | Sep 18, 1986 |
| 01002C | 1910.1025 Lead OSHA citation code: 19101025 F01 | Willful | 1 | - | $0 | $3,500 | Mar 27, 1984 | Mar 2, 1984 | Sep 18, 1986 |
| 01002D | 1910.1025 Lead OSHA citation code: 19101025 F03 I | Willful | 1 | - | $0 | $0 | Feb 24, 1984 | Mar 2, 1984 | Sep 18, 1986 |
| 01002E | 1910.1025 Lead OSHA citation code: 19101025 F03 II | Willful | 1 | - | $0 | $0 | Mar 8, 1984 | Mar 2, 1984 | Sep 18, 1986 |
| 01002F | 1910.1025 Lead OSHA citation code: 19101025 F04 I | Willful | 1 | - | $0 | $0 | Mar 27, 1984 | Mar 2, 1984 | Sep 18, 1986 |
Showing the 5 violations listed first by citation identifier. This inspection has 32 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 20, 1983#214785404Jan 20, 1983Planned (H) · Complete scope, Safety#214785404$1605 viol.5 violations$160 in penalties
Inspection #214785404
Dates
- Opened
- Jan 20, 1983
- Closing Conference Date
- Jan 26, 1983
- Closed
- Jun 17, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 25
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 1 serious, 4 other-than-serious
- Initial Penalties
- $160
- Penalties on Record
- $160
- Site Address
- 877 Addison Rd, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 1 | - | $160 | $160 | Feb 3, 1983 | - | - |
| 02001 | 1910.141 Sanitation OSHA citation code: 19100141 C02 I | Other | 1 | - | $0 | $0 | Mar 3, 1983 | - | - |
| 02002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | - | $0 | $0 | Feb 3, 1983 | - | - |
| 02003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 2 | - | $0 | $0 | Feb 3, 1983 | - | - |
| 02004 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Other | 1 | - | $0 | $0 | Mar 3, 1983 | - | - |
Apr 20, 1981#214921827Apr 20, 1981Planned (H) · Partial scope, Health#214921827$90027 viol.27 violations$900 in penalties
Inspection #214921827
Dates
- Opened
- Apr 20, 1981
- Closing Conference Date
- Oct 1, 1981
- Contested
- Dec 15, 1981
- Closed
- Mar 30, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 67
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 27
- Violation Types
- 27 serious
- Initial Penalties
- $9,710
- Penalties on Record
- $900
- Site Address
- 877 Addison Road, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 27 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 A | Serious | 3 | - | $800 | $0 | Jun 15, 1981 | Dec 15, 1981 | - |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B01 | Serious | 4 | - | $0 | $0 | Sep 14, 1981 | Dec 15, 1981 | - |
| 01001C | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B03 | Serious | 4 | - | $0 | $0 | Jun 15, 1981 | Dec 15, 1981 | - |
| 02001A | 1910.134 Respiratory Protection OSHA citation code: 19100134 A02 | Serious | 1 | - | $810 | $0 | Dec 23, 1981 | Dec 15, 1981 | - |
| 02001B | 1910.1000 Air Contaminants OSHA citation code: 19101000 D02 I | Serious | 1 | - | $0 | $0 | Oct 25, 1982 | Dec 15, 1981 | - |
Showing the 5 violations listed first by citation identifier. This inspection has 27 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 12, 1981#215007980Mar 12, 1981Planned (H) · Complete scope, Safety#215007980$35016 viol.16 violations$350 in penalties
Inspection #215007980
Dates
- Opened
- Mar 12, 1981
- Closing Conference Date
- Mar 17, 1981
- Closed
- Oct 7, 1981
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 5 serious, 11 other-than-serious
- Initial Penalties
- $1,160
- Penalties on Record
- $350
- Site Address
- 877 Addison Road, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 C | Serious | 1 | - | $200 | $60 | Apr 5, 1981 | - | - |
| 01002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A | Serious | 4 | - | $280 | $85 | Jul 14, 1981 | - | - |
| 01003 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 3 | - | $320 | $95 | May 18, 1981 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | - | $160 | $50 | Apr 9, 1981 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | - | $200 | $60 | May 4, 1981 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 16 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Feb 5, 1976#214796591Feb 5, 1976Planned (H) · Complete scope, Safety#214796591$253 viol.3 violations$25 in penalties
Inspection #214796591
Dates
- Opened
- Feb 5, 1976
- Closing Conference Date
- Feb 5, 1976
- Closed
- Jun 10, 1976
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $25
- Penalties on Record
- $25
- Site Address
- 877 Addison Road, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 2 | - | $0 | $0 | Mar 22, 1976 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 2 | - | $25 | $25 | Mar 22, 1976 | - | - |
| 01003 | 1910.309 OSHA citation code: 19100309 A 011017 | Other | 2 | - | $0 | $0 | Mar 5, 1976 | - | - |
Sep 11, 1973#214792509Sep 11, 1973Follow-Up (F) · Complete scope, Safety#214792509$00 viol.0 violations$0 in penalties
Inspection #214792509
Dates
- Opened
- Sep 11, 1973
- Closing Conference Date
- Sep 11, 1973
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 60
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 877 Addison Road, Cleveland, OH 44103
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
11 inspections, 1973 to 1988. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.