AJAY ENTERPRISES CORP
$710
penalties
23
viol.
3
insp.

AJAY ENTERPRISES CORP

1501 E. WISCONSIN ST., DELAVAN, WI 53115

Inspections
3
Oct 1973 to Feb 1988 · 3 safety, 0 health
Violations
23
across 3 inspections
Penalties on record
$710
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 18

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 12, 1988Planned (H) · Complete scope, Safety#101377059$2406 viol.

Inspection #101377059

Dates

Opened
Feb 12, 1988
Closing Conference Date
Feb 12, 1988
Closed
Mar 29, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
155

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$240
Penalties on Record
$240
Site Address
1501 E. Wisconsin St., Delavan, WI 53115
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious31$120$120Apr 6, 1988--
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IC
Serious11$120$120Apr 6, 1988--
020011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other11$0$0Mar 21, 1988--
020021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Other11$0$0Mar 14, 1988--
020031910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other13$0$0Mar 14, 1988--
020041910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other135$0$0Apr 6, 1988--
Feb 28, 1985Planned (H) · Complete scope, Safety#2218519$30011 viol.

Inspection #2218519

Dates

Opened
Feb 28, 1985
Closing Conference Date
Mar 1, 1985
Closed
Oct 21, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
210

Violations and Penalties

Total Violations
11
Violation Types
3 serious, 8 other-than-serious
Initial Penalties
$300
Penalties on Record
$300
Site Address
214 Wright Street, Delavan, WI 53115
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious35$300$300Apr 8, 1985--
01001B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious51$0$0May 7, 1985--
01001C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 VI
Serious510$0$0May 7, 1985--
020011910.25
Stairways
OSHA citation code: 19100025 D01 I
Other11$0$0Mar 10, 1985--
020021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other11$0$0Mar 14, 1985--
020031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Other11$0$0Mar 10, 1985--
020041910.217
Mechanical Power Presses
OSHA citation code: 19100217 C03 IVD
Other110$0$0Apr 8, 1985--
020051910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 II
Other125$0$0Apr 8, 1985--
020061910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other15$0$0Mar 10, 1985--
020071910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Other11$0$0Mar 8, 1985--
020081910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other13$0$0Apr 8, 1985--
Oct 2, 1973Planned (H) · Complete scope, Safety#15548837$1706 viol.

Inspection #15548837

Dates

Opened
Oct 2, 1973
Closing Conference Date
Oct 2, 1973
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Not displayed
Number of Employees
216

Violations and Penalties

Total Violations
6
Violation Types
6 other-than-serious
Initial Penalties
$170
Penalties on Record
$170
Site Address
1501 East Wisconsin Street, Delavan, WI 53115
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M05 III
Other1-$45$45Oct 9, 1973--
010021910.178
Powered Industrial Trucks
OSHA citation code: 19100178 M07
Other1-$45$45Nov 26, 1973--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other8-$45$45Nov 26, 1973--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other8-$35$35Nov 26, 1973--
010051910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A05 III
Other1-$0$0Nov 26, 1973--
010061910.309
OSHA citation code: 19100309 A 011017
Other1-$0$0Oct 26, 1973--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses6 citations · $420
1910.178Powered Industrial Trucks3 citations · $90
1910.304Electrical - Wiring Design and Protection3 citations · $0

Other inspected employers in DELAVAN, WI