Skip to content
SafetyRecord logoSafetyRecord
BRANDT ENGINEERING COMPANY, INC.
$1,789
penalties
21
viol.
11
insp.

BRANDT ENGINEERING COMPANY, INC.

1906 N. CROCKETT, DALLAS, TX 75201

Inspections
11
Oct 1987 to Mar 1997 · 9 safety, 2 health
Violations
21
across 11 inspections
Penalties on record
$1,789
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 0Other 15

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 6, 1997Planned (H) · Partial scope, Safety#116314303$00 viol.

Inspection #116314303

Dates

Opened
Mar 6, 1997
Closing Conference Date
Mar 6, 1997
Closed
Apr 1, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
8

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Mar 21, 1995Planned (H) · Partial scope, Safety#109096768$1,4592 viol.

Inspection #109096768

Dates

Opened
Mar 21, 1995
Closing Conference Date
Mar 21, 1995
Closed
May 25, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
66

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,431
Penalties on Record
$1,459
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.251
Rigging Equipment for Material Handling
OSHA citation code: 19260251 E08
Serious12$1,418$851May 8, 1995--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Serious11$1,013$608May 8, 1995--
Feb 4, 1992Planned (H) · Complete scope, Safety#103558854$00 viol.

Inspection #103558854

Dates

Opened
Feb 4, 1992
Closing Conference Date
Feb 5, 1992
Closed
Apr 24, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
500

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 31, 1991Planned (H) · Complete scope, Safety#106690357$00 viol.

Inspection #106690357

Dates

Opened
May 31, 1991
Closing Conference Date
Jun 5, 1991
Closed
Jun 20, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 24, 1988Planned (H) · Complete scope, Safety#101431484$02 viol.

Inspection #101431484

Dates

Opened
Oct 24, 1988
Closing Conference Date
Nov 8, 1988
Closed
Dec 22, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
21

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.350
Gas Welding and Cutting
OSHA citation code: 19260350 H
Other11$0$0Dec 12, 1988--
010021926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 E01 III
Other321$0$0Dec 12, 1988--
Jun 7, 1988Planned (H) · Complete scope, Safety#100480250$601 viol.

Inspection #100480250

Dates

Opened
Jun 7, 1988
Closing Conference Date
Jun 9, 1988
Closed
Aug 15, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
50

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$160
Penalties on Record
$60
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious11$160$60Jul 24, 1988--
Jan 5, 1988Complaint (B) · Complete scope, Health#2440337$00 viol.

Inspection #2440337

Dates

Opened
Jan 5, 1988
Closing Conference Date
Jan 14, 1988
Closed
Feb 4, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
68
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jan 5, 1988Complaint (B) · Complete scope, Safety#2440170$27010 viol.

Inspection #2440170

Dates

Opened
Jan 5, 1988
Closing Conference Date
Jan 14, 1988
Closed
Apr 15, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
68
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 7 other-than-serious
Initial Penalties
$180
Penalties on Record
$270
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious14$180$180Mar 17, 1988--
01001B1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B01
Serious14$0$0Mar 17, 1988--
01002B1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F07 IVC
Serious12$0$90Mar 17, 1988--
020011926.302
Power-Operated Hand Tools
OSHA citation code: 19260302 E03
Other12$0$0Mar 17, 1988--
020021926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 E
Other14$0$0Mar 17, 1988--

Showing the 5 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 24, 1987Complaint (B) · Complete scope, Safety#100788389$05 viol.

Inspection #100788389

Dates

Opened
Nov 24, 1987
Closing Conference Date
Nov 30, 1987
Closed
Mar 3, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
68
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
5 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.350
Gas Welding and Cutting
OSHA citation code: 19260350 A09
Other11$0$0Dec 31, 1987--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other12$0$0Dec 31, 1987--
010031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 E01
Other12$0$0Dec 31, 1987--
010041926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other12$0$0Dec 31, 1987--
010051926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 B08
Other11$0$0Dec 31, 1987--
Nov 24, 1987Unprogrammed Related (G) · Complete scope, Health#100788256$00 viol.

Inspection #100788256

Dates

Opened
Nov 24, 1987
Closing Conference Date
Nov 30, 1987
Closed
Apr 5, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
68
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1906 N. Crockett, Dallas, TX 75201
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Inspections 1 to 10 of 11, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)5 citations · $608
1926.404Electrical - Wiring Design and Protection (Construction)4 citations · $270
1926.500Fall Protection - Scope, Application, and Definitions3 citations · $0

Other inspected employers in DALLAS, TX

All employers in DALLAS →