Skip to content
SafetyRecord logoSafetyRecord
KEMBERLY, INC.
$6,733
penalties
51
viol.
10
insp.

KEMBERLY, INC.

23720 REEDY DRIVE, ELKHART, IN 46514

Inspections
10
Jun 1984 to Dec 2005 · 9 safety, 1 health
Violations
51
across 10 inspections
Penalties on record
$6,733
latest amounts in DOL records
By classification
Serious 18Willful 0Repeat 0Other 33

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 13, 2005Planned (H) · Complete scope, Safety#309063287$1,4793 viol.

Inspection #309063287

Dates

Opened
Dec 13, 2005
Closing Conference Date
Dec 13, 2005
Closed
Feb 8, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
89

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$2,275
Penalties on Record
$1,479
Site Address
201 East Simonton Street, Elkhart, IN 46514
Industry
331316

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious36$1,300$845Feb 13, 2006--
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Serious12$975$634Feb 13, 2006--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 II
Other120$0$0Feb 13, 2006--
Jan 10, 2005Planned (H) · No Inspection scope, Safety#308205780$00 viol.

Inspection #308205780

Dates

Opened
Jan 10, 2005
Closing Conference Date
Jan 10, 2005
Closed
Feb 3, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
201 East Simonton, Elkhart, IN 46514
Industry
331316

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Mar 22, 2002Planned (H) · Complete scope, Safety#125351247$02 viol.

Inspection #125351247

Dates

Opened
Mar 22, 2002
Closing Conference Date
Mar 22, 2002
Closed
Aug 28, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
23720 Reedy Drive, Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q07
Other13$0$0May 3, 2002--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 E
Other26$0$0May 3, 2002--
Jun 14, 2000Accident (A) · Partial scope, Safety#300719259$1,5751 viol.

Inspection #300719259

Dates

Opened
Jun 14, 2000
Closing Conference Date
Jun 20, 2000
Closed
Oct 17, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
122
Related Activity
1 accident

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$3,150
Penalties on Record
$1,575
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$3,150$1,575Sep 15, 2000--
Feb 10, 2000Complaint (B) · Partial scope, Health#127441723$00 viol.

Inspection #127441723

Dates

Opened
Feb 10, 2000
Closing Conference Date
Feb 16, 2000
Closed
Mar 30, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
135
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Jan 10, 1994Planned (H) · Complete scope, Safety#124044199$2,10012 viol.

Inspection #124044199

Dates

Opened
Jan 10, 1994
Closing Conference Date
Jan 10, 1994
Closed
Apr 13, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
125

Violations and Penalties

Total Violations
12
Violation Types
4 serious, 8 other-than-serious
Initial Penalties
$4,900
Penalties on Record
$2,100
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$1,050$525Mar 20, 1994--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$1,050$525Mar 6, 1994--
010031910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious1125$1,050$525Mar 20, 1994--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious1125$1,050$525Mar 20, 1994--
02001400.402Other1125$700$0Mar 6, 1994--

Showing the 5 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 27, 1990Planned (H) · Complete scope, Safety#108639667$84118 viol.

Inspection #108639667

Dates

Opened
Jun 27, 1990
Closing Conference Date
Jun 27, 1990
Closed
Sep 14, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
100

Violations and Penalties

Total Violations
18
Violation Types
6 serious, 12 other-than-serious
Initial Penalties
$1,120
Penalties on Record
$841
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious21$350$263Sep 20, 1990--
01002A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Serious11$280$210Sep 20, 1990--
01002B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 III
Serious11$0$0Sep 20, 1990--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious21$210$158Sep 20, 1990--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious21$0$0Sep 20, 1990--

Showing the 5 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Nov 17, 1986Follow-Up (F) · Partial scope, Safety#2691640$00 viol.

Inspection #2691640

Dates

Opened
Nov 17, 1986
Closing Conference Date
Nov 17, 1986
Closed
Nov 21, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 12, 1986Planned (H) · Complete scope, Safety#2691715$58810 viol.

Inspection #2691715

Dates

Opened
Aug 12, 1986
Closing Conference Date
Aug 14, 1986
Closed
Jan 11, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 7 other-than-serious
Initial Penalties
$588
Penalties on Record
$588
Site Address
23720 Reedy Dr., Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$280$280Sep 8, 1986--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious24$28$28Sep 29, 1986--
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious310$280$280Sep 29, 1986--
02001400.402Other195$0$0Sep 29, 1986--
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other14$0$0Sep 8, 1986--

Showing the 5 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 21, 1984Planned (H) · Complete scope, Safety#14747513$1505 viol.

Inspection #14747513

Dates

Opened
Jun 21, 1984
Closing Conference Date
Jun 22, 1984
Closed
Aug 6, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
98

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$150
Penalties on Record
$150
Site Address
23720 Reedy Drive, Elkhart, IN 46514
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious22$150$150Aug 6, 1984--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious22$0$0Aug 6, 1984--
020011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other11$0$0Jul 12, 1984--
020021910.308
Electrical - Special Systems
OSHA citation code: 19100308 B03
Other112$0$0Aug 6, 1984--
02003400.402Other190$0$0Aug 6, 1984--
Inspections 1 to 10 of 10, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.212General Requirements for All Machines (Machine Guarding)6 citations · $3,516
1910.217Mechanical Power Presses5 citations · $490
1910.303Electrical - General Requirements4 citations · $210

Other inspected employers in ELKHART, IN

All employers in ELKHART →