Skip to content
SafetyRecord logoSafetyRecord
SILVERCREEK WOODWORKS INC
$4,400
penalties
47
viol.
8
insp.

SILVERCREEK WOODWORKS INC

20551 BUILDERS CT, BEND, OR 97701NAICS 337110 Wood Kitchen Cabinet and Countertop Manufacturing

Inspections
8
Apr 2000 to Jan 2009 · 5 safety, 3 health
Violations
47
across 8 inspections
Penalties on record
$4,400
latest amounts in DOL records
By classification
Serious 24Willful 0Repeat 0Other 23

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 15, 2009Planned (H) · Complete scope, Safety#312264468$00 viol.

Inspection #312264468

Dates

Opened
Jan 15, 2009
Closing Conference Date
Jan 15, 2009
Closed
Jan 15, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
799 Sw Columbia St, Bend, OR 97701
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 10, 2008Referral (C) · Partial scope, Health#312262827$00 viol.

Inspection #312262827

Dates

Opened
Nov 10, 2008
Closing Conference Date
Dec 10, 2008
Closed
Dec 10, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
20551 Builders Ct, Bend, OR 97701
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Oct 14, 2008Planned (H) · Complete scope, Safety#312261985$6307 viol.

Inspection #312261985

Dates

Opened
Oct 14, 2008
Closing Conference Date
Oct 17, 2008
Closed
Aug 26, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16

Violations and Penalties

Total Violations
7
Violation Types
5 serious, 2 other-than-serious
Initial Penalties
$630
Penalties on Record
$630
Site Address
20551 Builders Ct, Bend, OR 97701
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 M01
Serious11$165$165Nov 14, 2008--
01002702016105
OSHA citation code: 702016105 A AV
Serious116$165$165Nov 14, 2008--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious13$100$100Oct 14, 2008--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02 I
Serious73$100$100Oct 14, 2008--
010051910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious13$100$100Oct 14, 2008--
020061910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Other12$0$0Nov 14, 2008--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 20, 2004Planned (H) · Complete scope, Health#308131549$8508 viol.

Inspection #308131549

Dates

Opened
Oct 20, 2004
Closing Conference Date
Nov 30, 2004
Closed
Apr 21, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
24

Violations and Penalties

Total Violations
8
Violation Types
5 serious, 3 other-than-serious
Initial Penalties
$850
Penalties on Record
$850
Site Address
20551 Builders Ct, Bend, OR 97701
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1052
Methylene Chloride
OSHA citation code: 19101052 D02
Serious22$500$500Jan 23, 2005--
01001B1910.1052
Methylene Chloride
OSHA citation code: 19101052 C02
Serious22$0$0Jan 23, 2005--
01002A1910.1052
Methylene Chloride
OSHA citation code: 19101052 L01
Serious32$350$350Nov 30, 2004--
01002B1910.1052
Methylene Chloride
OSHA citation code: 19101052 G01 I
Serious32$0$0Nov 30, 2004--
01002C1910.1052
Methylene Chloride
OSHA citation code: 19101052 H01
Serious32$0$0Nov 30, 2004--
020031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Other112$0$0Feb 6, 2005--

Showing the 6 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 19, 2004Complaint (B) · Partial scope, Health#306602186$2706 viol.

Inspection #306602186

Dates

Opened
Feb 19, 2004
Closing Conference Date
Apr 2, 2004
Closed
Jan 20, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$270
Penalties on Record
$270
Site Address
20551 Builders Ct, Bend, OR 97701
Industry
238130 Framing Contractors

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious41$270$270May 8, 2004--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious41$0$0May 8, 2004--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Serious41$0$0May 8, 2004--
01001D1910.134
Respiratory Protection
OSHA citation code: 19100134 K03
Serious41$0$0May 8, 2004--
02002A1910.1048
Formaldehyde
OSHA citation code: 19101048 D01 I
Other21$0$0May 22, 2004--
02002B1910.1048
Formaldehyde
OSHA citation code: 19101048 N03 I
Other21$0$0May 8, 2004--
Feb 26, 2003Planned (H) · Complete scope, Safety#305135204$53012 viol.

Inspection #305135204

Dates

Opened
Feb 26, 2003
Closing Conference Date
Feb 26, 2003
Closed
Aug 7, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
41

Violations and Penalties

Total Violations
12
Violation Types
3 serious, 9 other-than-serious
Initial Penalties
$530
Penalties on Record
$530
Site Address
20551 Builders Ct, Bend, OR 97701
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious11$165$165Apr 11, 2003--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious22$200$200Feb 26, 2003--
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious11$165$165Apr 11, 2003--
020041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C02
Other33$0$0Apr 11, 2003--
020051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C03
Other33$0$0Apr 11, 2003--
020061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other22$0$0Apr 11, 2003--

Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 5, 2000Follow-Up (F) · Partial scope, Safety#303308761$00 viol.

Inspection #303308761

Dates

Opened
Jun 5, 2000
Closing Conference Date
Jun 5, 2000
Closed
Jun 5, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
36

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
741 Se Glenwood Drive, Bend, OR 97702
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 6, 2000Planned (H) · Complete scope, Safety#303307045$2,12014 viol.

Inspection #303307045

Dates

Opened
Apr 6, 2000
Closing Conference Date
Apr 7, 2000
Closed
Nov 24, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
36

Violations and Penalties

Total Violations
14
Violation Types
7 serious, 7 other-than-serious
Initial Penalties
$2,120
Penalties on Record
$2,120
Site Address
741 Se Glenwood Drive, Bend, OR 97702
Industry
337110 Wood Kitchen Cabinet and Countertop Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious136$270$270May 22, 2000--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 E01 V
Serious136$180$180Apr 7, 2000--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C02 II
Serious11$180$180Apr 7, 2000--
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious13$270$270May 10, 2000--
010051910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 J03
Serious14$270$270May 10, 2000--
010061910.23
Ladders
OSHA citation code: 19100023 C01
Serious14$180$180Apr 7, 2000--

Showing the 6 violations listed first by citation identifier. This inspection has 14 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $400
1910.213Woodworking Machinery Requirements6 citations · $975
1910.1052Methylene Chloride5 citations · $850

Industry comparison

Violations per inspection
This employer5.9
Industry average3.9
Penalties per inspection
This employer$550
Industry average$1,963

Furniture and Related Product Manufacturing, 12,798 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in BEND, OR

All employers in BEND →