Skip to content
SafetyRecord logoSafetyRecord
TORPEDO SPECIALTY WIRE, INC.
$20,694
penalties
109
viol.
5
insp.

TORPEDO SPECIALTY WIRE, INC.

1115 INSTRUMENT DRIVE, ROCKY MOUNT, NC 27804NAICS 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Inspections
5
Oct 1997 to Feb 2011 · 2 safety, 3 health
Violations
109
across 5 inspections
Penalties on record
$20,694
latest amounts in DOL records
By classification
Serious 56Willful 0Repeat 6Other 47

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 22, 2011Planned (H) · Complete scope, Health#314878489$6,75035 viol.

Inspection #314878489

Dates

Opened
Feb 22, 2011
Closing Conference Date
Mar 8, 2011
Closed
Jul 28, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
35
Violation Types
28 serious, 7 other-than-serious
Initial Penalties
$9,000
Penalties on Record
$6,750
Site Address
1115 Instrument Drive, Rocky Mount, NC 27804
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 35 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.106
Flammable Liquids
OSHA citation code: 19100106 D03 II
Serious13$600$450May 10, 2011--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Serious12$1,000$750Jun 15, 2011--
01002B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious12$0$0Jun 15, 2011--
01002C1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C04
Serious12$0$0Jun 15, 2011--
01002D1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C05 IIC
Serious12$0$0Jun 15, 2011--
01002E1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Serious12$0$0Jun 15, 2011--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious12$1,000$750May 31, 2011--
010041910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious23$600$450May 10, 2011--
01005A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A06
Serious22$1,000$750May 10, 2011--
01005B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 K01
Serious11$0$0May 10, 2011--

Showing the 10 violations listed first by citation identifier. This inspection has 35 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 11, 2005Planned (H) · Complete scope, Safety#309317022$5636 viol.

Inspection #309317022

Dates

Opened
Oct 11, 2005
Closing Conference Date
Oct 11, 2005
Closed
Feb 15, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
49

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 3 other-than-serious
Initial Penalties
$563
Penalties on Record
$563
Site Address
1115 Instrument Drive, Rocky Mount, NC 27804
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious11$375$375Oct 31, 2005--
01002A1910.23
Ladders
OSHA citation code: 19100023 C01
Serious14$188$188Nov 22, 2005--
01002B1910.26
Dockboards
OSHA citation code: 19100026 C02 VII
Serious11$0$0Oct 31, 2005--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other13$0$0Nov 22, 2005--
02002A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other22$0$0Nov 22, 2005--
02002B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Other22$0$0Nov 22, 2005--
Jun 20, 2002Planned (H) · Complete scope, Health#305039034$2,43841 viol.

Inspection #305039034

Dates

Opened
Jun 20, 2002
Closing Conference Date
Jul 16, 2002
Closed
Oct 18, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
54

Violations and Penalties

Total Violations
41
Violation Types
14 serious, 27 other-than-serious
Initial Penalties
$2,438
Penalties on Record
$2,438
Site Address
1115 Instrument Drive, Rocky Mount, NC 27804
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 41 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010019501.2901Serious12$375$375Sep 26, 2002--
01002A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01 I
Serious27$375$375Sep 5, 2002--
01002B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 F03
Serious17$0$0Sep 26, 2002--
01002C1910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$0$0Sep 26, 2002--
01002D1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious16$0$0Sep 5, 2002--
01003A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$0$0Sep 5, 2002--
01003B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious411$0$0Sep 5, 2002--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious11$525$525Sep 5, 2002--
010051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$113$113Sep 5, 2002--
01006A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious12$525$525Sep 5, 2002--

Showing the 10 violations listed first by citation identifier. This inspection has 41 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 13, 1997Planned (H) · Complete scope, Health#301961496$1,6638 viol.

Inspection #301961496

Dates

Opened
Oct 13, 1997
Closing Conference Date
Oct 31, 1997
Closed
Dec 1, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
90

Violations and Penalties

Total Violations
8
Violation Types
1 serious, 1 repeat, 6 other-than-serious
Initial Penalties
$2,375
Penalties on Record
$1,663
Site Address
1115 Instrument Drive, Rocky Mount, NC 27804
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Repeat12$1,750$1,225Jan 20, 1998--
020011910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$625$438Jan 20, 1998--
03001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other11$0$0Feb 4, 1998--
03001B1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other13$0$0Feb 4, 1998--
03002A1910.141
Sanitation
OSHA citation code: 19100141 G02
Other12$0$0Jan 20, 1998--
03002B1910.1025
Lead
OSHA citation code: 19101025 H01
Other12$0$0Jan 20, 1998--
030031910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C03
Other11$0$0Feb 4, 1998--
030041910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other13$0$0Feb 4, 1998--
Oct 8, 1997Planned (H) · Complete scope, Safety#301961132$9,28019 viol.

Inspection #301961132

Dates

Opened
Oct 8, 1997
Closing Conference Date
Oct 16, 1997
Closed
Jan 5, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
90

Violations and Penalties

Total Violations
19
Violation Types
10 serious, 5 repeat, 4 other-than-serious
Initial Penalties
$13,245
Penalties on Record
$9,280
Site Address
1115 Instrument Drive, Rocky Mount, NC 27804
Industry
332813 Electroplating, Plating, Polishing, Anodizing, and Coloring

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 19 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Repeat24$3,500$2,450Dec 5, 1997--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Repeat128$2,450$1,720Dec 5, 1997--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Repeat11$140$100Nov 20, 1997--
020021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Repeat21$140$100Dec 5, 1997--
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Repeat24$140$100Dec 5, 1997--
030011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Serious34$375$260Dec 5, 1997--
030021910.23
Ladders
OSHA citation code: 19100023 C03
Serious13$1,250$875Dec 5, 1997--
03003A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious13$1,750$1,225Dec 5, 1997--
03003B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A05
Serious15$0$0Nov 20, 1997--
03003C1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious12$0$0Dec 5, 1997--

Showing the 10 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment13 citations · $4,420
1910.212General Requirements for All Machines (Machine Guarding)10 citations · $4,650
1910.303Electrical - General Requirements8 citations · $1,975

Industry comparison

Violations per inspection
This employer21.8
Industry average3.3
Penalties per inspection
This employer$4,139
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in ROCKY MOUNT, NC

All employers in ROCKY MOUNT →