This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a complaint inspection of C.H.I. MANUFACTURING at 3065 S. Umitilla St., Englewood, CO 80110 on Jul 9, 2002. The inspection scope was partial. The case was closed on Jul 15, 2003.

OSHA documented 32 violations (27 serious, 5 other-than-serious) with total penalties on record of $5,040. This inspection is linked to 1 complaint in OSHA records.

This employer has 4 other OSHA inspections on record at this establishment.

Inspection Details

Inspection Number
305170292
Type
Complaint (B)
Scope
Partial
Opened
Jul 9, 2002
Closed
Jul 15, 2003
Contested
Sep 20, 2002
Final Order
May 27, 2003
Total Violations
32
Penalties on Record
$5,040
Initial Penalties
$12,600
Related Activity
1 complaint
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Establishment

Address
3065 S. Umitilla St., Englewood, CO 80110
Industry
332322 Sheet Metal Work Manufacturing

Other Inspections of This Employer4 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Jul 15, 2003.

Citations on Record
32

27 serious, 5 other-than-serious.

Initial Penalties
$12,600

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$5,040

Latest published amounts after changes in the enforcement process.

Citation contest activity appears on Sep 20, 2002. Final orders are recorded through May 27, 2003. Penalty changes shown on this page reflect the latest amounts published in OSHA's enforcement data.

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious$1,500$600Sep 19, 2002Sep 20, 2002May 27, 2003
010021910.38
Emergency Action Plans
OSHA citation code: 19100038 A02
Serious$450$180Sep 19, 2002Sep 20, 2002May 27, 2003
010031910.110
Storage and Handling of Liquefied Petroleum Gases
OSHA citation code: 19100110 F02 I
Serious$600$240Sep 19, 2002Sep 20, 2002May 27, 2003
01004A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D01
Serious$1,500$600Sep 19, 2002Sep 20, 2002May 27, 2003
01004B1910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01004C1910.136
Foot Protection
OSHA citation code: 19100136 A
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01005A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious$1,500$600Sep 19, 2002Sep 20, 2002May 27, 2003
01005B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01005C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C05 I
Serious$0$0Aug 28, 2002Sep 20, 2002May 27, 2003
01005D1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
010061910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious$600$240Sep 19, 2002Sep 20, 2002May 27, 2003
01007A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Serious$600$240Sep 19, 2002Sep 20, 2002May 27, 2003
01007B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01007C1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E03
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01007D1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 F02
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01008A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 A05
Serious$1,500$600Aug 28, 2002Sep 20, 2002May 27, 2003
01008B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
010091910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious$750$300Sep 19, 2002Sep 20, 2002May 27, 2003
010101910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Serious$750$300Aug 28, 2002Sep 20, 2002May 27, 2003
010111910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C03
Serious$450$180Aug 28, 2002Sep 20, 2002May 27, 2003
010121910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious$450$180Sep 19, 2002Sep 20, 2002May 27, 2003
010131910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Serious$450$180Aug 28, 2002Sep 20, 2002May 27, 2003
01014A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Serious$450$180Sep 19, 2002Sep 20, 2002May 27, 2003
01014B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01015A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Serious$450$180Sep 19, 2002Sep 20, 2002May 27, 2003
01015B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
01015C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A02
Other$300$120Sep 19, 2002Sep 20, 2002May 27, 2003
020021910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other$0$0Sep 19, 2002Sep 20, 2002May 27, 2003
020031910.23
Ladders
OSHA citation code: 19100023 D01 II
Other$300$120Sep 19, 2002Sep 20, 2002May 27, 2003
020041910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other$0$0Aug 28, 2002Sep 20, 2002May 27, 2003
020051910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other$0$0Sep 19, 2002Sep 20, 2002May 27, 2003

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.