This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

The Occupational Safety and Health Administration (OSHA) conducted a planned inspection of KOLCRAFT ENTERPRISES, INC. at 10832 Nc Hwy. 211 East, Aberdeen, NC 28315 on Dec 11, 2002. The inspection scope was complete. The case was closed on Jun 20, 2003.

OSHA documented 37 violations (23 serious, 14 other-than-serious) with total penalties on record of $5,400.

This employer has 3 other OSHA inspections on record at this establishment.

Inspection Details
Inspection Number
306137779
Type
Planned (H)
Scope
Complete
Opened
Dec 11, 2002
Closed
Jun 20, 2003
Total Violations
37
Penalties on Record
$5,400
Initial Penalties
$13,700
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Establishment
Address
10832 Nc Hwy. 211 East, Aberdeen, NC 28315
Industry
339932
Other Inspections of This Employer3 on record

Other OSHA inspections of the same establishment. Linked via establishment ID (exact government key).

Enforcement Outcome

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page.

Status on Record
Closed

Inspection closed Jun 20, 2003.

Citations on Record
37

23 serious, 14 other-than-serious.

Initial Penalties
$13,700

Citation amounts as first recorded in OSHA's penalty fields.

Current Penalties
$5,400

Latest published amounts after changes in the enforcement process.

Violations

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

CitationStandardTypeInitialCurrentAbatementContestFinal Order
010019501.2901Serious$500$225Apr 24, 2003--
01002A1910.23
Ladders
OSHA citation code: 19100023 E01
Serious$700$375May 15, 2003--
01002B1910.23
Ladders
OSHA citation code: 19100023 C01
Serious$0$0May 15, 2003--
01002C1910.23
Ladders
OSHA citation code: 19100023 D01 III
Serious$0$0May 15, 2003--
01003A1910.25
Stairways
OSHA citation code: 19100025 D01 I
Serious$1,400$450May 15, 2003--
01003B1910.25
Stairways
OSHA citation code: 19100025 D01 IV
Serious$0$0May 15, 2003--
01003C1910.25
Stairways
OSHA citation code: 19100025 D01 X
Serious$0$0May 15, 2003--
010041910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious$1,400$750Jun 6, 2003--
010051910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious$500$375May 15, 2003--
01006A1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Serious$1,400$750May 15, 2003--
01006B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L03 IM
Serious$0$0Apr 24, 2003--
01006C1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 Q05
Serious$0$0May 15, 2003--
01007A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious$1,400$525May 15, 2003--
01007B1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious$0$0May 15, 2003--
01007C1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious$0$0May 15, 2003--
01009A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Serious$1,000$750May 15, 2003--
01009B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious$0$0May 15, 2003--
01009C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 G
Serious$0$0May 15, 2003--
01010A1910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 A
Serious$1,000$375May 15, 2003--
01010B1910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious$0$0May 15, 2003--
010111910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 B02
Serious$300$225May 15, 2003--
010121910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 E06 II
Serious$1,400$225May 15, 2003--
010131910.254
Arc Welding and Cutting
OSHA citation code: 19100254 D09 III
Other$700$0May 15, 2003--
01014A1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other$2,000$0May 15, 2003--
01014B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J04 IVA
Serious$0$375May 15, 2003--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other$0$0May 15, 2003--
020021910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Other$0$0Jun 6, 2003--
02003A1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other$0$0Jun 6, 2003--
02003B1910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 D04
Other$0$0Apr 24, 2003--
020041910.158
Standpipe and Hose Systems
OSHA citation code: 19100158 E01 II
Other$0$0Jun 6, 2003--
020051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other$0$0May 15, 2003--
02006A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other$0$0May 15, 2003--
02006B1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other$0$0May 15, 2003--
02006C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other$0$0May 15, 2003--
02006D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Other$0$0May 15, 2003--
02006E1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Other$0$0May 15, 2003--
02006F1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Other$0$0Apr 24, 2003--

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. On inspection pages, the status display follows the DOL inspection record first. If the DOL inspection feed includes a close date, we show the inspection as closed. If the inspection feed has no close date but all citation records tied to that inspection show a final order date, we label the page "Final Order Recorded" and disclose the citation dates instead of inferring a close date. Chemical exposure sampling data and OSHA Permissible Exposure Limits (PELs) are sourced from the OSHA Occupational Chemical Database, matched via IMIS analyte codes. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.