TRANSPORTATION SECURITY ADMINISTRATION
4000 W 50TH AVE STE 300, ANCHORAGE, AK 99502 · NAICS 926120
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Nov 13, 2013#339483398Nov 13, 2013Planned (H) · Complete scope, Safety#339483398$03 viol.3 violations$0 in penalties
Inspection #339483398
Dates
- Opened
- Nov 13, 2013
- Closing Conference Date
- Nov 13, 2013
- Final Order
- Dec 12, 2013
- Closed
- Dec 27, 2013
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 48
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4000 W 50th Ave Ste 300, Anchorage, AK 99502
- Industry
- 926120
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 II | Serious | 2 | 48 | $0 | $0 | Dec 31, 2013 | - | Dec 12, 2013 |
| 01002 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 B03 I | Serious | 1 | 20 | $0 | $0 | Dec 12, 2013 | - | Dec 12, 2013 |
| 01003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 J01 I | Serious | 1 | 20 | $0 | $0 | Dec 12, 2013 | - | Dec 12, 2013 |
Feb 2, 2011#307507244Feb 2, 2011Planned (H) · Complete scope, Health#307507244$04 viol.4 violations$0 in penalties
Inspection #307507244
Dates
- Opened
- Feb 2, 2011
- Closing Conference Date
- Feb 2, 2011
- Closed
- Mar 1, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 290
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 2 serious, 1 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4000 W 50th Ave Ste 300, Anchorage, AK 99502
- Industry
- 926120
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.36 Design and Construction Requirements for Exit Routes OSHA citation code: 19100036 G02 | Serious | 1 | 3 | $0 | $0 | Feb 17, 2011 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 3 | $0 | $0 | Feb 11, 2011 | - | - |
| 02001 | 1904.32 Annual Summary OSHA citation code: 19040032 B06 | Repeat | 1 | 1 | $0 | $0 | Feb 11, 2011 | - | - |
| 03001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 III | Other | 1 | 3 | $0 | $0 | Feb 24, 2011 | - | - |
Feb 2, 2011#307507236Feb 2, 2011Planned (H) · Complete scope, Safety#307507236$05 viol.5 violations$0 in penalties
Inspection #307507236
Dates
- Opened
- Feb 2, 2011
- Closing Conference Date
- Feb 2, 2011
- Closed
- Mar 3, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 290
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 1 serious, 3 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4000 W 50th Ave Ste 300, Anchorage, AK 99502
- Industry
- 926120
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Serious | 1 | 2 | $0 | $0 | Mar 10, 2011 | - | - |
| 02001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Repeat | 1 | 4 | $0 | $0 | Mar 10, 2011 | - | - |
| 02002 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B04 | Repeat | 2 | 6 | $0 | $0 | Mar 10, 2011 | - | - |
| 02003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 | Repeat | 1 | 4 | $0 | $0 | Feb 24, 2011 | - | - |
| 03001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 3 | - | $0 | $0 | Feb 24, 2011 | - | - |
Jan 8, 2007#307500975Jan 8, 2007Planned (H) · Complete scope, Safety#307500975$010 viol.10 violations$0 in penalties
Inspection #307500975
Dates
- Opened
- Jan 8, 2007
- Closing Conference Date
- Jan 9, 2007
- Closed
- Feb 7, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 240
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 3 serious, 2 repeat, 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Anchorage International Airport, Anchorage, AK 99502
- Industry
- 926120
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.101 Compressed Gases (General Requirements) OSHA citation code: 19100101 B | Serious | 1 | 2 | $0 | $0 | Feb 20, 2007 | - | - |
| 01002A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 3 | 5 | $0 | $0 | Feb 20, 2007 | - | - |
| 01002B | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Serious | 1 | 5 | $0 | $0 | Jan 22, 2007 | - | - |
| 02003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Repeat | 1 | 5 | $0 | $0 | Feb 20, 2007 | - | - |
| 02004 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 I | Repeat | 1 | 2 | $0 | $0 | Feb 20, 2007 | - | - |
| 03001 | 1904.40 Providing records to government representatives OSHA citation code: 19040040 A | Other | 1 | 5 | $0 | $0 | Feb 20, 2007 | - | - |
| 03002 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 II | Other | 1 | 2 | $0 | $0 | Jan 22, 2007 | - | - |
| 03003 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 A02 IIIG | Other | 1 | 2 | $0 | $0 | Feb 20, 2007 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 5, 2006#307499640Jan 5, 2006Planned (H) · Complete scope, Health#307499640$04 viol.4 violations$0 in penalties
Inspection #307499640
Dates
- Opened
- Jan 5, 2006
- Closing Conference Date
- Jan 9, 2006
- Closed
- May 12, 2006
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 240
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Anchorage International Airport, Anchorage, AK 99502
- Industry
- 926120
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Serious | 7 | 22 | $0 | $0 | Feb 14, 2006 | - | - |
| 01002 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 18 | 4 | $0 | $0 | Apr 30, 2006 | - | - |
| 01003 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $0 | $0 | Jan 17, 2006 | - | - |
| 01004 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Serious | 1 | 5 | $0 | $0 | Jan 17, 2006 | - | - |
Jun 2, 2004#301503546Jun 2, 2004Referral (C) · Complete scope, Health#301503546$012 viol.12 violations$0 in penalties
Inspection #301503546
Dates
- Opened
- Jun 2, 2004
- Closing Conference Date
- Jun 7, 2004
- Closed
- Oct 26, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- No
- Number of Employees
- 346
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 7 serious, 1 repeat, 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Anchorage International Airport, Anchorage, AK 99502
- Industry
- 926120
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (8 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 3 | 62 | $0 | $0 | Oct 31, 2004 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 7 | $0 | $0 | Jul 22, 2004 | - | - |
| 01004 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 1 | 5 | $0 | $0 | Jul 29, 2004 | - | - |
| 01005 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 B02 | Serious | 1 | 2 | $0 | $0 | Jul 29, 2004 | - | - |
| 01006 | 1910.1096 Ionizing Radiation OSHA citation code: 19101096 D01 | Serious | 10 | 321 | $0 | $0 | Aug 30, 2004 | - | - |
| 01007 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 II | Serious | 1 | 15 | $0 | $0 | Jul 19, 2004 | - | - |
| 01008 | 1960.8 Agency Responsibilities OSHA citation code: 19600008 A | Serious | 1 | 5 | $0 | $0 | Oct 31, 2004 | - | - |
| 02001 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Repeat | 1 | 321 | $0 | $0 | Jul 22, 2004 | - | - |
Showing the 8 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
16 inspections, 2004 to 2018. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Public Administration, 4,123 employers with OSHA inspections. Arithmetic from DOL records.