U.S. AIR FORCE
ALASKAN AIR COMMAND, ELMENDORF AIR FORCE BASE, AK 99506
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 19, 2009#307505248Oct 19, 2009Planned (H) · Complete scope, Safety#307505248$03 viol.3 violations$0 in penalties
Inspection #307505248
Dates
- Opened
- Oct 19, 2009
- Closing Conference Date
- Oct 30, 2009
- Closed
- Jul 1, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 300
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Equipment Maintenance Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Repeat | 1 | 2 | $0 | $0 | May 24, 2010 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Repeat | 1 | 25 | $0 | $0 | Dec 17, 2009 | - | - |
| 02001 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | 1 | $0 | $0 | Nov 18, 2009 | - | - |
Oct 19, 2009#307505222Oct 19, 2009Planned (H) · Complete scope, Safety#307505222$04 viol.4 violations$0 in penalties
Inspection #307505222
Dates
- Opened
- Oct 19, 2009
- Closing Conference Date
- Oct 26, 2009
- Closed
- Jul 1, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 300
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 1 serious, 2 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Serious | 1 | 1 | $0 | $0 | Dec 17, 2009 | - | - |
| 02001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Repeat | 2 | 2 | $0 | $0 | May 24, 2010 | - | - |
| 02002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Repeat | 1 | 25 | $0 | $0 | Dec 17, 2009 | - | - |
| 03001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 I | Other | 2 | 1 | $0 | $0 | Dec 17, 2009 | - | - |
Oct 19, 2009#307505206Oct 19, 2009Planned (H) · Complete scope, Health#307505206$02 viol.2 violations$0 in penalties
Inspection #307505206
Dates
- Opened
- Oct 19, 2009
- Closing Conference Date
- Oct 30, 2009
- Closed
- Mar 1, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 300
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Equipment Maintenance Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Other | 1 | 2 | $0 | $0 | Dec 17, 2009 | - | - |
| 01002 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 G05 | Other | 2 | 5 | $0 | $0 | May 24, 2010 | - | - |
Oct 19, 2009#307505180Oct 19, 2009Planned (H) · Complete scope, Health#307505180$07 viol.7 violations$0 in penalties
Inspection #307505180
Dates
- Opened
- Oct 19, 2009
- Closing Conference Date
- Oct 30, 2009
- Closed
- Feb 23, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 300
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 5 serious, 1 repeat, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 A09 | Serious | 1 | 30 | $0 | $0 | Dec 17, 2009 | - | - |
| 01002 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $0 | $0 | Nov 18, 2009 | - | - |
| 01003A | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 G05 | Serious | 1 | 100 | $0 | $0 | Dec 17, 2009 | - | - |
| 01003B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 IVA | Serious | 1 | 100 | $0 | $0 | Nov 18, 2009 | - | - |
| 01003C | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 100 | $0 | $0 | Dec 17, 2009 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 17, 2007#307501049Jan 17, 2007Planned (H) · Complete scope, Safety#307501049$07 viol.7 violations$0 in penalties
Inspection #307501049
Dates
- Opened
- Jan 17, 2007
- Closing Conference Date
- Jan 19, 2007
- Closed
- Feb 23, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 275
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 4 serious, 1 repeat, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 D01 IV | Serious | 1 | 4 | $0 | $0 | Feb 27, 2007 | - | - |
| 01002 | 1910.184 Slings OSHA citation code: 19100184 D | Serious | 1 | 2 | $0 | $0 | Jan 29, 2007 | - | - |
| 01003A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 2 | $0 | $0 | Feb 27, 2007 | - | - |
| 01003B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 2 | $0 | $0 | Jan 29, 2007 | - | - |
| 02001 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F04 | Repeat | 1 | 2 | $0 | $0 | Feb 27, 2007 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 17, 2007#307500991Jan 17, 2007Planned (H) · Complete scope, Health#307500991$01 viol.1 violation$0 in penalties
Inspection #307500991
Dates
- Opened
- Jan 17, 2007
- Closing Conference Date
- Jan 19, 2007
- Closed
- Mar 28, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 275
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.134 Respiratory Protection OSHA citation code: 19100134 H02 I | Serious | 1 | 1 | $0 | $0 | Jan 29, 2007 | - | - |
Jan 11, 2005#307498303Jan 11, 2005Planned (H) · Complete scope, Safety#307498303$03 viol.3 violations$0 in penalties
Inspection #307498303
Dates
- Opened
- Jan 11, 2005
- Closing Conference Date
- Jan 20, 2005
- Closed
- Mar 18, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 58
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 2 repeat
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Equipment Maintenance Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 488190 Other Support Activities for Air Transportation
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 1 | 2 | $0 | $0 | Mar 24, 2005 | - | - |
| 02001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Repeat | 2 | 4 | $0 | $0 | Mar 24, 2005 | - | - |
| 02002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Repeat | 1 | 1 | $0 | $0 | Mar 24, 2005 | - | - |
Jan 11, 2005#307498287Jan 11, 2005Planned (H) · Complete scope, Safety#307498287$012 viol.12 violations$0 in penalties
Inspection #307498287
Dates
- Opened
- Jan 11, 2005
- Closing Conference Date
- Jan 20, 2005
- Closed
- May 19, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 275
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 7 serious, 3 repeat, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Serious | 4 | 4 | $0 | $0 | Mar 24, 2005 | - | - |
| 01002 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 2 | 4 | $0 | $0 | Mar 24, 2005 | - | - |
| 01003A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C02 I | Serious | 2 | 4 | $0 | $0 | May 24, 2005 | - | - |
| 01003B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 C03 | Serious | 1 | 1 | $0 | $0 | May 24, 2005 | - | - |
| 01003C | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 2 | 5 | $0 | $0 | May 24, 2005 | - | - |
Showing the 5 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 11, 2005#307498220Jan 11, 2005Planned (H) · Complete scope, Health#307498220$01 viol.1 violation$0 in penalties
Inspection #307498220
Dates
- Opened
- Jan 11, 2005
- Closing Conference Date
- Jan 20, 2005
- Closed
- Mar 17, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 58
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Equipment Maintenance Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 488190 Other Support Activities for Air Transportation
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 2 | $0 | $0 | Mar 24, 2005 | - | - |
Jan 11, 2005#307498212Jan 11, 2005Planned (H) · Complete scope, Health#307498212$05 viol.5 violations$0 in penalties
Inspection #307498212
Dates
- Opened
- Jan 11, 2005
- Closing Conference Date
- Jan 20, 2005
- Closed
- Mar 17, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Federal
- Union Status
- Yes
- Number of Employees
- 275
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 3rd Civil Engineering Squadron, Elmendorf Air Force Base, AK 99506
- Industry
- 561210 Facilities Support Services
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.36 Design and Construction Requirements for Exit Routes OSHA citation code: 19100036 D01 | Serious | 1 | 5 | $0 | $0 | Mar 24, 2005 | - | - |
| 01001B | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 A03 | Serious | 1 | 5 | $0 | $0 | Mar 24, 2005 | - | - |
| 01001C | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 B02 | Serious | 1 | 5 | $0 | $0 | Mar 24, 2005 | - | - |
| 01002 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $0 | $0 | Feb 24, 2005 | - | - |
| 01003 | 1910.253 Oxygen-Fuel Gas Welding and Cutting OSHA citation code: 19100253 B04 I | Serious | 1 | 6 | $0 | $0 | Feb 24, 2005 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
22 inspections, 1986 to 2009. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.