Skip to content
SafetyRecord logoSafetyRecord
ATLANTIC PRECAST CONCRETE, INC.
$8,960
penalties
40
viol.
8
insp.

ATLANTIC PRECAST CONCRETE, INC.

10823 BEAVER DAM RD, Cockeysville, MD 21030

Inspections
8
Dec 1982 to Jul 2009 · 5 safety, 3 health
Violations
40
across 8 inspections
Penalties on record
$8,960
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 28

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 23, 2009Referral (C) · Partial scope, Safety#313579864$1,0007 viol.

Inspection #313579864

Dates

Opened
Jul 23, 2009
Closing Conference Date
Jul 29, 2009
Closed
Sep 24, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
21
Related Activity
1 referral

Violations and Penalties

Total Violations
7
Violation Types
1 serious, 6 other-than-serious
Initial Penalties
$1,000
Penalties on Record
$1,000
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
327390 Other Concrete Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious11$1,000$1,000Aug 14, 2009--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Other810$0$0Aug 18, 2009--
020021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B04
Other110$0$0Aug 18, 2009--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other13$0$0Aug 14, 2009--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Other33$0$0Aug 18, 2009--
020051910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Other16$0$0Aug 18, 2009--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 19, 2008Planned (H) · Complete scope, Safety#311923486$1,4856 viol.

Inspection #311923486

Dates

Opened
Mar 19, 2008
Closing Conference Date
Mar 19, 2008
Closed
May 22, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$2,475
Penalties on Record
$1,485
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
327390 Other Concrete Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Serious12$1,650$745Apr 28, 2008--
010021910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B05 IIG
Serious14$825$740Apr 24, 2008--
020011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other12$0$0Apr 24, 2008--
020021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other12$0$0Apr 24, 2008--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Other14$0$0Apr 28, 2008--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other12$0$0Apr 28, 2008--
Jun 14, 2004Accident (A) · Partial scope, Health#307877159$3,2007 viol.

Inspection #307877159

Dates

Opened
Jun 14, 2004
Closing Conference Date
Sep 2, 2004
Closed
Mar 2, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
45
Related Activity
1 accident

Violations and Penalties

Total Violations
7
Violation Types
3 serious, 4 other-than-serious
Initial Penalties
$19,125
Penalties on Record
$3,200
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
327332 Concrete Pipe Manufacturing

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

HospitalizationJun 14, 2004

Three employees in kiln suffer carbon monoxide poisoning

Injury: Poisoning (Systemic)Body part: BloodSource: GasesEvent: Inhalation3 injury lines on this record

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Carbon Monoxide32482 - 2944ppm

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
020011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Serious33$3,825$800Nov 8, 2004--
020021910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious33$3,825$800Nov 8, 2004--
020031910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Serious33$3,825$800Nov 8, 2004--
030011910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Other33$3,825$400Nov 8, 2004--
030021910.1000
Air Contaminants
OSHA citation code: 19101000 E
Other13$3,825$400Nov 8, 2004--
040011910.23
Ladders
OSHA citation code: 19100023 C01
Other13$0$0Nov 8, 2004--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 2, 2001Referral (C) · Partial scope, Safety#304692791$8002 viol.

Inspection #304692791

Dates

Opened
Aug 2, 2001
Closing Conference Date
Aug 17, 2001
Closed
Dec 11, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$2,850
Penalties on Record
$800
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious44$2,850$800Oct 11, 2001--
01001B1910.178
Powered Industrial Trucks
OSHA citation code: 19100178 P01
Other22$0$0Oct 11, 2001--
Jul 25, 2001Planned (H) · Complete scope, Health#304566060$1,50012 viol.

Inspection #304566060

Dates

Opened
Jul 25, 2001
Closing Conference Date
Aug 17, 2001
Closed
Jan 16, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
12
Violation Types
3 serious, 9 other-than-serious
Initial Penalties
$4,750
Penalties on Record
$1,500
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious11$1,900$1,000Oct 16, 2001--
02001A912.2303
OSHA citation code: 09122303 A
Serious260$2,850$500Oct 16, 2001--
02001B912.2303
OSHA citation code: 09122303 B
Serious260$0$0Oct 16, 2001--
030011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 D01
Other13$0$0Oct 28, 2001--
030021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other12$0$0Nov 13, 2001--
030031910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 D02
Other160$0$0Oct 16, 2001--

Showing the 6 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 14, 1995Planned (H) · Complete scope, Safety#119571628$9754 viol.

Inspection #119571628

Dates

Opened
Jul 14, 1995
Closing Conference Date
Jul 24, 1995
Closed
Oct 3, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$975
Penalties on Record
$975
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious11$450$450Sep 7, 1995--
020011910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious110$525$525Sep 8, 1995--
030011910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Other14$0$0Sep 8, 1995--
030021910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 II
Other12$0$0Sep 7, 1995--
Jul 12, 1995Planned (H) · Complete scope, Health#119590412$02 viol.

Inspection #119590412

Dates

Opened
Jul 12, 1995
Closing Conference Date
Aug 17, 1995
Closed
Nov 16, 1995

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
10823 Beaver Dam Road, Cockeysville, MD 21030
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Other12$0$0Oct 11, 1995--
0100250406
OSHA citation code: 50406 A01
Other150$0$0Oct 11, 1995--
Dec 27, 1982Planned (H) · Partial scope, Safety#12462388$00 viol.

Inspection #12462388

Dates

Opened
Dec 27, 1982
Closing Conference Date
Dec 27, 1982
Closed
Dec 28, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
12
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
10823 Beaver Dam Rd, Cockeysville, MD 21030
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.303Electrical - General Requirements7 citations · $525
1910.132Personal Protective Equipment - General Requirements3 citations · $800
1910.146Permit-Required Confined Spaces3 citations · $2,400

Chemical exposure sampling

Samples
3
Substances
1
Inspections
1

Other inspected employers in Cockeysville, MD