Skip to content
SafetyRecord logoSafetyRecord
HOLMDEL TOWNSHIP DEPARTMENT OF PUBLIC WORKS, LEAF
$0
penalties
23
viol.
6
insp.

HOLMDEL TOWNSHIP DEPARTMENT OF PUBLIC WORKS, LEAF

4 CRAWFORDS CORNER ROAD, HOLMDEL, NJ 07733NAICS 561210 Facilities Support Services

Inspections
6
Jun 2004 to Apr 2010 · 6 safety, 0 health
Violations
23
across 6 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 23Willful 0Repeat 0Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 7, 2010Follow-Up (F) · Partial scope, Safety#314708678$00 viol.

Inspection #314708678

Dates

Opened
Apr 7, 2010
Closing Conference Date
Apr 7, 2010
Closed
Apr 7, 2010

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
922120

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 15, 2010Planned (H) · Complete scope, Safety#314064148$05 viol.

Inspection #314064148

Dates

Opened
Jan 15, 2010
Closing Conference Date
Jan 15, 2010
Closed
Apr 7, 2010

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
59

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
922120

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious1359$0$0Jan 29, 2010--
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B07 IV
Serious159$0$0Mar 30, 2010--
010031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A02 I
Serious459$0$0Mar 30, 2010--
010041910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious159$0$0Mar 30, 2010--
010051910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 II
Serious159$0$0Mar 30, 2010--
Nov 5, 2007Complaint (B) · Partial scope, Safety#310913348$05 viol.

Inspection #310913348

Dates

Opened
Nov 5, 2007
Closing Conference Date
Nov 5, 2007
Closed
Nov 5, 2007

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
32
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
561210 Facilities Support Services

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 C
Serious332$0$0Nov 26, 2007--
010021910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Serious132$0$0Nov 26, 2007--
010031910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 I
Serious132$0$0Jan 22, 2008--
010041910.36
Design and Construction Requirements for Exit Routes
OSHA citation code: 19100036 E01
Serious132$0$0Nov 26, 2007--
010051910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B02
Serious132$0$0Nov 26, 2007--
Mar 2, 2005Follow-Up (F) · Partial scope, Safety#308364074$00 viol.

Inspection #308364074

Dates

Opened
Mar 2, 2005
Closing Conference Date
Mar 2, 2005
Closed
Mar 2, 2005

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
561210 Facilities Support Services

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 28, 2004Planned (H) · Complete scope, Safety#308358787$013 viol.

Inspection #308358787

Dates

Opened
Dec 28, 2004
Closing Conference Date
Dec 28, 2004
Closed
Mar 2, 2005

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
13
Violation Types
13 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
561210 Facilities Support Services

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious220$0$0Mar 11, 2005--
010021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 A
Serious120$0$0Mar 11, 2005--
010031910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious120$0$0Mar 11, 2005--
010041910.169
Air Receivers
OSHA citation code: 19100169 A02 I
Serious120$0$0Mar 11, 2005--
010051910.176
Handling Materials - General
OSHA citation code: 19100176 B
Serious620$0$0Mar 11, 2005--
010061910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 J03
Serious120$0$0Mar 11, 2005--
010071910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 L03 III
Serious120$0$0Mar 11, 2005--
010081910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious220$0$0Mar 11, 2005--

Showing the 8 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 18, 2004Planned (H) · Partial scope, Safety#306936857$00 viol.

Inspection #306936857

Dates

Opened
Jun 18, 2004
Closing Conference Date
Jun 18, 2004
Closed
Jun 18, 2004

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
26

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4 Crawfords Corner Road, Holmdel, NJ 07733
Industry
561210 Facilities Support Services

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $0
1910.24Step Bolts and Manhole Steps3 citations · $0
1910.179Overhead and Gantry Cranes2 citations · $0

Industry comparison

Violations per inspection
This employer3.8
Industry average1.6
Penalties per inspection
This employer$0
Industry average$1,872

Administrative and Support Services, 53,376 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in HOLMDEL, NJ

All employers in HOLMDEL →