Skip to content
SafetyRecord logoSafetyRecord
SEMINOLE PRECAST MANUFACTURING, INC.
$22,025
penalties
43
viol.
8
insp.

SEMINOLE PRECAST MANUFACTURING, INC.

331 BENSON JUNCTION RD, DE BARY, FL 32713NAICS 327332 Concrete Pipe Manufacturing

Inspections
8
Jul 1999 to Jul 2008 · 3 safety, 5 health
Violations
43
across 8 inspections
Penalties on record
$22,025
latest amounts in DOL records
By classification
Serious 31Willful 0Repeat 4Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 9, 2008Follow-Up (F) · Complete scope, Safety#311816441$00 viol.

Inspection #311816441

Dates

Opened
Jul 9, 2008
Closing Conference Date
Jul 9, 2008
Closed
Dec 1, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
70

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327390 Other Concrete Product Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 24, 2008Referral (C) · Partial scope, Health#311814842$2,8501 viol.

Inspection #311814842

Dates

Opened
Mar 24, 2008
Closing Conference Date
Mar 25, 2008
Closed
Aug 25, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
113
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$5,600
Penalties on Record
$2,850
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327390 Other Concrete Product Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Repeat35$5,600$2,850Jul 18, 2008--
Mar 18, 2008Planned (H) · Complete scope, Safety#311814701$13,12522 viol.

Inspection #311814701

Dates

Opened
Mar 18, 2008
Closing Conference Date
Mar 26, 2008
Closed
Dec 1, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
113

Violations and Penalties

Total Violations
22
Violation Types
17 serious, 3 repeat, 2 other-than-serious
Initial Penalties
$25,800
Penalties on Record
$13,125
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327390 Other Concrete Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 22 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.133
Eye and Face Protection
OSHA citation code: 19100133 A01
Serious15$4,000$2,000May 13, 2008--
01001B1910.138
Hand Protection
OSHA citation code: 19100138 A
Serious210$0$0May 13, 2008--
01002A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F07
Serious15$2,000$1,050May 13, 2008--
01002B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F08
Serious15$0$0May 13, 2008--
01002C1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F09
Serious15$0$0May 13, 2008--
01002D1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 F10
Serious15$0$0May 13, 2008--

Showing the 6 violations listed first by citation identifier. This inspection has 22 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 20, 2005Follow-Up (F) · Complete scope, Health#308434562$00 viol.

Inspection #308434562

Dates

Opened
Oct 20, 2005
Closing Conference Date
Oct 20, 2005
Closed
Oct 24, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
184

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327390 Other Concrete Product Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 9, 2005Planned (H) · Complete scope, Health#308428531$4,95013 viol.

Inspection #308428531

Dates

Opened
Feb 9, 2005
Closing Conference Date
Apr 15, 2005
Closed
Oct 24, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
130

Violations and Penalties

Total Violations
13
Violation Types
12 serious, 1 other-than-serious
Initial Penalties
$8,250
Penalties on Record
$4,950
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327332 Concrete Pipe Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC30.4777 - 1.1075mg/m³
Sample WeightQC30.363 - 0.819mg
Silica, Crystalline Quartz (Respirable Fraction)30 - 2.8%

Violations

Violation list (6 of 13 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious12$825$495May 11, 2005--
010021910.29
Fall Protection Systems and Criteria
OSHA citation code: 19100029 A03 VII
Serious11$1,100$660May 11, 2005--
010031910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious39$1,375$825Jun 30, 2005--
01004A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious15$825$495May 11, 2005--
01004B1910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Serious15$0$0May 11, 2005--
01004C1910.134
Respiratory Protection
OSHA citation code: 19100134 F01
Serious15$0$0May 11, 2005--

Showing the 6 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 13, 2000Planned (H) · No Inspection scope, Health#303982748$00 viol.

Inspection #303982748

Dates

Opened
Dec 13, 2000
Closing Conference Date
Not recorded
Closed
Jan 17, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327332 Concrete Pipe Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Dec 13, 2000Planned (H) · Complete scope, Safety#303982615$00 viol.

Inspection #303982615

Dates

Opened
Dec 13, 2000
Closing Conference Date
Dec 13, 2000
Closed
Dec 13, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
95

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327332 Concrete Pipe Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Jul 21, 1999Complaint (B) · Partial scope, Health#302732177$1,1007 viol.

Inspection #302732177

Dates

Opened
Jul 21, 1999
Closing Conference Date
Jul 21, 1999
Closed
Nov 30, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
102
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
2 serious, 5 other-than-serious
Initial Penalties
$1,100
Penalties on Record
$1,100
Site Address
331 Benson Junction Rd, De Bary, FL 32713
Industry
327332 Concrete Pipe Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC32P / 1A0.0861 - 0.6681mg/m³
Sample WeightQC42P / 2A0 - 0.314mg
Silica, Crystalline Quartz (Respirable Fraction)32P / 1A0
Silica (Quartz, Total)14%

Violations

Violation list (6 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Serious15$1,100$1,100Nov 24, 1999--
01001B1910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C02
Serious65$0$0Dec 10, 1999--
02001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Other15$0$0Dec 10, 1999--
02001B1910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other15$0$0Dec 10, 1999--
02001C1910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Other55$0$0Nov 24, 1999--
020021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other15$0$0Dec 10, 1999--

Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.146Permit-Required Confined Spaces9 citations · $2,150
1910.134Respiratory Protection8 citations · $495
1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $6,825

Chemical exposure sampling

Samples
20
Substances
4
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer5.4
Industry average3.3
Penalties per inspection
This employer$2,753
Industry average$2,364

Nonmetallic Mineral Product Manufacturing, 17,265 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in DE BARY, FL