Skip to content
SafetyRecord logoSafetyRecord
WIRE-MESH PRODUCTS, INCORPORATED
$19,351
penalties
34
viol.
7
insp.

WIRE-MESH PRODUCTS, INCORPORATED

501 EAST KING STREET, YORK, PA 17405NAICS 332618 Other Fabricated Wire Product Manufacturing

Inspections
7
Mar 1985 to Aug 2022 · 6 safety, 1 health
Violations
34
across 7 inspections
Penalties on record
$19,351
latest amounts in DOL records
By classification
Serious 25Willful 0Repeat 0Other 9

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 22, 2022Complaint (B) · Partial scope, Safety#346165434$11,0004 viol.

Inspection #346165434

Dates

Opened
Aug 22, 2022
Closing Conference Date
Aug 22, 2022
Final Order
Mar 8, 2023
Closed
Apr 14, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
4 serious
Initial Penalties
$15,626
Penalties on Record
$11,000
Site Address
501 East King Street, York, PA 17403
Industry
332618 Other Fabricated Wire Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious13$7,813$11,000Apr 17, 2023-Mar 8, 2023
01001B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious13$0$0Apr 17, 2023-Mar 8, 2023
01001C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious13$0$0Apr 17, 2023-Mar 8, 2023
01001D1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious15$7,813$0Apr 17, 2023-Mar 8, 2023
Oct 15, 2008Complaint (B) · Partial scope, Safety#312499056$8552 viol.

Inspection #312499056

Dates

Opened
Oct 15, 2008
Closing Conference Date
Oct 16, 2008
Closed
Nov 4, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
52
Related Activity
1 complaint

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,225
Penalties on Record
$855
Site Address
501 East King Street, York, PA 17405
Industry
332618 Other Fabricated Wire Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 C01
Serious15$700$490Nov 21, 2008--
010021910.133
Eye and Face Protection
OSHA citation code: 19100133 A05
Serious13$525$365Nov 21, 2008--
Mar 3, 2005Planned (H) · Complete scope, Health#308471077$1,48010 viol.

Inspection #308471077

Dates

Opened
Mar 3, 2005
Closing Conference Date
Apr 6, 2005
Closed
Jun 13, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
10
Violation Types
6 serious, 4 other-than-serious
Initial Penalties
$2,275
Penalties on Record
$1,480
Site Address
501 East King Street, York, PA 17405
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious152$700$460May 31, 2005--
010021910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious32$525$340May 24, 2005--
010031910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B02 III
Serious11$525$340May 24, 2005--
01004A1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious11$525$340May 24, 2005--
01004B1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C04 I
Serious12$0$0May 24, 2005--
01004C1910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 I
Serious12$0$0May 24, 2005--
020011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L04 III
Other11$0$0May 24, 2005--

Showing the 7 violations listed first by citation identifier. This inspection has 10 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Dec 12, 2002Planned (H) · Partial scope, Safety#305834780$4402 viol.

Inspection #305834780

Dates

Opened
Dec 12, 2002
Closing Conference Date
Dec 12, 2002
Closed
Jan 29, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
43

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$675
Penalties on Record
$440
Site Address
501 East King Street, York, PA 17405
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$675$440Feb 6, 2003--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Other12$0$0Feb 6, 2003--
May 9, 2000Planned (H) · Complete scope, Safety#112659107$7963 viol.

Inspection #112659107

Dates

Opened
May 9, 2000
Closing Conference Date
May 9, 2000
Closed
May 24, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
48

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$1,225
Penalties on Record
$796
Site Address
501 East King Street, York, PA 17405
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious110$1,225$796Jun 8, 2000--
01001B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious110$0$0Jun 8, 2000--
020011910.253
Oxygen-Fuel Gas Welding and Cutting
OSHA citation code: 19100253 B04 III
Other13$0$0Jun 8, 2000--
May 22, 1996Planned (H) · Complete scope, Safety#116152802$4,5009 viol.

Inspection #116152802

Dates

Opened
May 22, 1996
Closing Conference Date
May 22, 1996
Closed
Jul 10, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
40

Violations and Penalties

Total Violations
9
Violation Types
7 serious, 2 other-than-serious
Initial Penalties
$7,000
Penalties on Record
$4,500
Site Address
501 East King Street, York, PA 17405
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious11$1,750$1,135Jul 16, 1996--
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious66$1,750$1,135Jul 16, 1996--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious156$0$0Jul 16, 1996--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious46$1,750$1,135Jul 16, 1996--
01004A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Serious140$750$485Jul 16, 1996--
01004B1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious140$0$0Jul 16, 1996--
01004C1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious140$0$0Jul 16, 1996--

Showing the 7 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 27, 1985Planned (H) · Complete scope, Safety#1998921$2804 viol.

Inspection #1998921

Dates

Opened
Mar 27, 1985
Closing Conference Date
Apr 3, 1985
Closed
Jul 25, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$280
Penalties on Record
$280
Site Address
501 E King St, York, PA 17403
Industry
332618 Other Fabricated Wire Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious14$120$120Jun 2, 1985--
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious11$160$160Jun 2, 1985--
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$0$0Jun 2, 1985--
020011910.184
Slings
OSHA citation code: 19100184 E01
Other11$0$0May 7, 1985--
Inspections 1 to 7 of 7, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.147Control of Hazardous Energy (Lockout/Tagout)7 citations · $11,645
1910.1200Hazard Communication5 citations · $485
1910.213Woodworking Machinery Requirements4 citations · $1,735

Industry comparison

Violations per inspection
This employer4.9
Industry average3.3
Penalties per inspection
This employer$2,764
Industry average$2,308

Fabricated Metal Product Manufacturing, 47,284 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: spring and wire product manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 10.7%; NAICS 33261 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in YORK, PA

All employers in YORK →